Task #146 — Modbus addressing: align type codes with Wonderware DASMBTCP + Ignition
Web verification (2026-04-25) against current vendor docs surfaced concrete grammar conflicts in the v1 suffix grammar shipped in #137. Hard cutover before the Admin UI rolls out widely so users don't paste `:I` from a Wonderware spreadsheet and silently get wrong-typed reads. Sources: - Wonderware DASMBTCP user guide https://cdn.logic-control.com/media/DASMBTCP.pdf - Ignition Modbus addressing (8.1) https://www.docs.inductiveautomation.com/docs/8.1/ignition-modules/opc-ua/opc-ua-drivers/modbus/modbus-addressing Type-code changes: | Code | Pre-#146 | Post-#146 | Vendor reference | |--------|----------|------------|------------------------------| | `:S` | (n/a) | Int16 | Wonderware DASMBTCP `S` | | `:US` | (n/a) | UInt16 | Ignition `HRUS` | | `:I` | Int16 | **Int32** | Wonderware `I` + Ignition `HRI` | | `:UI` | UInt16 | **UInt32** | Ignition `HRUI` | | `:I_64` | (n/a) | Int64 | Ignition `HRI_64` | | `:UI_64` | (n/a) | UInt64 | Ignition `HRUI_64` | | `:BCD_32`| (n/a) | BCD32 | Ignition `HRBCD_32` | Codes REMOVED (no clear vendor precedent + conflict with the new mapping): `:DI`, `:L`, `:UDI`, `:UL`, `:LI`, `:ULI`, `:LBCD`. Pre-#146 configs that use them get an "Unknown type code" diagnostic at parse time so users get a fast surface-level error rather than silent wrong-typed reads. Codes UNCHANGED (already vendor-aligned): `:BOOL`, `:F`, `:D`, `:BCD`, `:STR<n>`. Modicon 5/6-digit + mnemonic regions (HR/IR/C/DI) + bit suffix `.N` are also unchanged. Defaults: - Coils / DiscreteInputs → `BOOL` (unchanged) - HoldingRegisters / InputRegisters with no explicit type → Int16 (matches Ignition's bare `HR` default) Byte-order mnemonics (`:ABCD` / `:CDAB` / `:BADC` / `:DCBA`) are kept but documented as OtOpcUa-specific — they aren't in any major vendor's per-tag address string. Ignition uses a `-R` suffix per prefix; Wonderware configures word-order at the topic level. Tests: - 12 Type_Codes_Parse rows updated to assert the new mappings. - New Removed_Aliases_Are_Rejected (×7) confirms each pre-#146 alias now fails fast with "Unknown type code". - Worked_Example_Int16_Array uses the new `:S` code. - New Worked_Example_Int32_Array_Via_I_Code documents the `:I = Int32` vendor-alignment intent so a future "fix" doesn't accidentally regress. - Unknown_Type_Code_Rejected_With_Catalog updated to match the new error message ("Valid: BOOL, S, US, I, ..."). Docs: - docs/v2/modbus-addressing.md — table replaced with the post-#146 codes, each row cites its Wonderware / Ignition reference. New "Codes removed in #146" subsection documents the cutover. - docs/Driver.Modbus.Cli.md — example grammar list updated; explicit type-code reminder appended. 114 addressing tests + 231 driver tests still green. Solution build clean. |
||
|
|
5ea57d2d70 |
Task #138 — Modbus addressing grammar docs + e2e
Closes the docs/e2e end of the Modbus addressing line shipped across #136-#145. Docs: - docs/v2/modbus-addressing.md (new) — full grammar reference. Region+offset (Modicon 5-digit / 6-digit / mnemonic), bit suffix, type codes (BOOL / I / UI / DI / UDI / LI / ULI / F / D / BCD / LBCD / STR<n>), all four byte-order mnemonics (ABCD / CDAB / BADC / DCBA), array-count semantics, family-native syntax (DL205 V/Y/C/X/SP and MELSEC D/M/X/Y with hex-vs-octal sub-family selection), driver-instance options (KeepAlive / Reconnect / IdleDisconnect, MaxCoilsPerRead and FC15/16 forcing, Deadband + WriteOnChangeOnly, MaxReadGap + CoalesceProhibited, multi-unit IPerCallHostResolver). Includes a worked JSON DTO example mixing AddressString + structured tag forms. - docs/Driver.Modbus.Cli.md — appended a "v2 addressing grammar" section pointing users at the full reference, with quick-reference examples. - Vendor-compatibility caveat documented: type codes and byte-order mnemonics were synthesised from training-era vendor docs (Wonderware DASMBTCP, Kepware KEPServerEX, Ignition, Matrikon, OAS) and should be verified against current vendor manuals before locking for production. E2E tests (4 new AddressingGrammarTests in IntegrationTests): - Modicon 5-digit and 6-digit forms map to identical wire offsets. - Float32 + WordSwap (CDAB) round-trips end-to-end through the pymodbus simulator. - Int16[5] array round-trips as a typed short[] surface. - Block-read coalescing produces a wire-acceptable PDU when MaxReadGap=5 bridges three nearby tags. All tests skip gracefully when the pymodbus simulator at localhost:5020 is unreachable (matches the existing ModbusSimulatorFixture pattern). Final test count across the Modbus addressing surface: - 107 ModbusAddressing.Tests (parser + family + Modicon) - 231 Driver.Modbus.Tests (driver, byte order, array, multi-unit, coalescing, protocol, subscribe, connection options) - 110 Admin.Tests (incl. ModbusOptionsViewModel defaults pinning) - 4 new AddressingGrammar integration tests (skip when sim down) |
||
|
|
5dac2e9375 |
Task #249 — Driver test-client CLIs: shared lib + Modbus CLI first
Mirrors the v1 otopcua-cli value prop (ad-hoc shell-level PLC validation) for
the Modbus-TCP driver, and lays down the shared scaffolding that AB CIP, AB
Legacy, S7, and TwinCAT CLIs will build on.
New projects:
- src/ZB.MOM.WW.OtOpcUa.Driver.Cli.Common/ — DriverCommandBase (verbose
flag + Serilog config) + SnapshotFormatter (single-tag + table +
write-result renders with invariant-culture value formatting + OPC UA
status-code shortnames + UTC-normalised timestamps).
- src/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Cli/ — otopcua-modbus-cli executable.
Commands: probe, read, write, subscribe. ModbusCommandBase carries the
host/port/unit-id flags + builds ModbusDriverOptions with Probe.Enabled
=false (CLI runs are one-shot; driver-internal keep-alive would race).
Commands + coverage:
- probe single FC03 + GetHealth() + pretty-print
- read region × address × type synth into one driver tag
- write same shape + --value parsed per --type
- subscribe polled-subscription stream until Ctrl+C
Tests (38 total):
- 16 SnapshotFormatterTests covering: status-code shortnames, unknown
codes fall back to hex, null value + timestamp placeholders, bool
lowercase, float invariant culture, string quoting, write-result shape,
aligned table columns, mismatched-length rejection, UTC normalisation.
- 22 Modbus CLI tests:
· ReadCommandTests.SynthesiseTagName (5 theory cases)
· WriteCommandParseValueTests (17 cases: bool aliases, unknown rejected,
Int16 bounds, UInt16/Bcd16 type, Float32/64 invariant culture,
String passthrough, BitInRegister, Int32 MinValue, non-numeric reject)
Wiring:
- ZB.MOM.WW.OtOpcUa.slnx grew 4 entries (2 src + 2 tests).
- docs/Driver.Modbus.Cli.md — operator-facing runbook with examples per
command + output format + typical workflows.
Regression: full-solution build clean; shared-lib tests 16/0, Modbus CLI tests
22/0.
Next up: repeat the pattern for AB CIP (shares ~40% more with Modbus via
libplctag), then AB Legacy, S7, TwinCAT. The shared base stays as-is unless
one of those exposes a gap the Modbus-first pass missed.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|