Commit Graph

4 Commits

Author SHA1 Message Date
Joseph Doherty 844f93f64f feat(adminui): B2-WP3 driver/device config modals + page-to-form refactor
Extract the 8 typed driver pages into embeddable <Driver>DriverForm bodies
(channel/protocol config) and add per-driver <Driver>DeviceForm bodies
(connection endpoint -> Device.DeviceConfig, v3 endpoint split). New
DriverConfigModal + DeviceModal dispatch by DriverType (DriverTypeNames) for
the /raw tree; Test-connect inside DeviceModal builds the merged Driver+Device
config transiently via DriverDeviceConfigMerger. Routed pages now host the
form bodies and keep working. Round-trip + enum-serialization guard tests for
the Modbus driver form + Modbus device model; retargeted the existing
page-form serialization tests + the _jsonOpts converter guard to the forms.

Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
2026-07-16 03:26:24 -04:00
Joseph Doherty 0b4b2e4cfd refactor(historian-gateway): retire Wonderware historian projects (gateway is sole backend)
The HistorianGateway driver is now the sole historian read/write+alarm backend, so the
Wonderware sidecar projects are dead code. Removes the 5 Wonderware projects (driver,
.Client, .Client.Contracts, + their 2 test projects) from the solution and tree, and fully
retires the vestigial 'Historian.Wonderware' driver type (UI/probe-only; it had no driver
factory): the Host probe registration, the AdminUI driver-config surface (driver page,
tag-config editor/model/validator entry, address picker/builder, driver-type catalog +
dropdown + edit-router entries), and their tests. Prunes the now-unused Wonderware
connection fields (Host/Port/UseTls/ServerCertThumbprint/SharedSecret) from
AlarmHistorianOptions (keeping Enabled + the SQLite store-and-forward knobs) and refreshes
the stale XML docs that named Wonderware as the production backend.

Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
2026-06-26 19:25:21 -04:00
Joseph Doherty a0dccbf8ee test(drivers): tighten driver-page converter guard + clarify S7 numeric case
Code-review follow-ups: the page-coverage test now asserts every *DriverPage
declares a _jsonOpts serializer (so a new page that serialises config a
different way fails the guard, not just converter removal); clarify that 40 ==
(int)S7CpuType.S71500 in the numeric-throws test.
2026-06-19 05:06:43 -04:00
Joseph Doherty 4b14feb373 fix(drivers): serialize driver-config enums as strings in AdminUI pages + probes
AdminUI driver-instance pages serialized enum config fields (S7 CpuType,
Modbus DataType/Region, AbCip PlcFamily, ...) as JSON *numbers* because each
page's _jsonOpts lacked a JsonStringEnumConverter. The driver factories,
however, deserialize into string-typed DTOs (+ lenient ParseEnum) and throw
when binding a JSON number to a string? — so an AdminUI-authored config
containing any enum field produced a blob the driver could not parse,
faulting the driver on deploy. Proven end-to-end for S7 and Modbus; latent
for AbCip/AbLegacy/TwinCAT/FOCAS/Galaxy/Historian. Only OpcUaClient was safe
(its factory + probe already carried the converter).

Add JsonStringEnumConverter to all 9 driver-instance pages' _jsonOpts and the
8 missing driver probes' _opts (factories unchanged — already string-via-
ParseEnum; strictly more permissive, also lets pages load hand-seeded
string-enum configs back into the form).

Also fix DriverProbeHandshakeE2eTests.AbCip_Green_AgainstSim to probe a real
sim tag (TestDINT) — the no-tags @raw_cpu_type fallback is rejected by the
ab_server sim with ErrorBadParam (a real ControlLogix returns ErrorNotFound,
which the probe treats as reachable; hardware-gated follow-up).

Tests: reflection guard over all driver pages' _jsonOpts (AdminUI.Tests);
factory round-trip + numeric-form-throws guards for S7 and Modbus.

Found by running the never-before-run FB-9/FB-10 live verifies.
2026-06-19 04:52:47 -04:00