dae520b9c06082c54e3557f2cce4da6210ba67e1
3 Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
850b816873 |
Task #137 — Modbus per-tag suffix grammar (type / bit / byte-order / array)
Adds the full Wonderware/Kepware/Ignition-style address suffix grammar so users paste tag spreadsheets without per-tag manual translation: <region><offset>[.<bit>][:<type>[<len>]][:<order>][:<count>] Examples that now parse end-to-end: 40001 HoldingRegisters[0], Int16 400001 same, 6-digit form 40001.5 bit 5 of HR[0] 40001:F Float32 (HR[0..1]) 40001:F:CDAB word-swapped Float32 40001:STR20 20-char ASCII string HR1:DI Int32 via mnemonic region C100 Coils[99] (mnemonic) 40001:F:5 Float32[5] array (3-field shorthand) 40001:I:CDAB:10 Int16[10] word-swapped (4-field strict) Driver-side plumbing: - ModbusAddressParser + ParsedModbusAddress in the shared Addressing assembly. 91 parser tests (every grammar variant + malformed shapes). - ModbusDataType / ModbusByteOrder moved to shared (with the same namespace so callers compile unchanged). ModbusByteOrder gains ByteSwap (BADC) and FullReverse (DCBA) alongside the existing BigEndian (ABCD) and WordSwap (CDAB). - NormalizeWordOrder extended to honor all four orders for both 4-byte and 8-byte values. Old WordSwap behavior preserved bit-for-bit. - ModbusTagDefinition gains optional ArrayCount. - ReadOneAsync / WriteOneAsync handle array fan-out: one FC03/04 read covers N consecutive register-typed elements, decoded into a typed array (short[], float[], etc.). Coil arrays use FC01 reads + FC15 writes (FakeTransport in tests gains FC15 support to match). - DriverAttributeInfo IsArray / ArrayDim flow from ArrayCount so the OPC UA address space surfaces ValueRank=1 + ArrayDimensions to clients. - ModbusDriverFactoryExtensions gains AddressString DTO field. When present, the parser drives Region/Address/DataType/ByteOrder/Bit/ StringLength/ArrayCount; structured fields (Writable, WriteIdempotent, StringByteOrder) still come from the DTO. Existing structured tag rows keep working unchanged. Tests: 91 parser unit tests (Driver.Modbus.Addressing.Tests, all green) + 204 driver tests including new ModbusByteOrderTests (BADC/DCBA roundtrips across Int32/Float32/Float64) and ModbusArrayTests (Int16[5], Float32[3] CDAB, Coil[10], length-mismatch error, IsArray/ArrayDim discovery). Solution-wide build clean. Caveat: grammar names (type codes, byte-order mnemonics, the :count shorthand) were synthesized from training-era vendor docs. Verify against current Kepware Modbus Ethernet Driver Help and Ignition Modbus Addressing manuals before freezing for production deployments — naming may need a back-compat layer if vendor wording has shifted. |
||
|
|
f3850f8914 |
Phase 6.1 Stream A.5/A.6 — WriteIdempotent flag on DriverAttributeInfo + Modbus/S7 tag records + FlakeyDriver integration tests
Per-tag opt-in for write-retry per docs/v2/plan.md decisions #44, #45, #143. Default is false — writes never auto-retry unless the driver author has marked the tag as safe to replay. Core.Abstractions: - DriverAttributeInfo gains `bool WriteIdempotent = false` at the end of the positional record (back-compatible; every existing call site uses the default). Driver.Modbus: - ModbusTagDefinition gains `bool WriteIdempotent = false`. Safe candidates documented in the param XML: holding-register set-points, configuration registers. Unsafe: edge-triggered coils, counter-increment addresses. - ModbusDriver.DiscoverAsync propagates t.WriteIdempotent into DriverAttributeInfo.WriteIdempotent. Driver.S7: - S7TagDefinition gains `bool WriteIdempotent = false`. Safe candidates: DB word/dword set-points, configuration DBs. Unsafe: M/Q bits that drive edge-triggered program routines. - S7Driver.DiscoverAsync propagates the flag. Stream A.5 integration tests (FlakeyDriverIntegrationTests, 4 new) exercise the invoker + flaky-driver contract the plan enumerates: - Read with 5 transient failures succeeds on the 6th attempt (RetryCount=10). - Non-idempotent write with RetryCount=5 configured still fails on the first failure — no replay (decision #44 guard at the ExecuteWriteAsync surface). - Idempotent write with 2 transient failures succeeds on the 3rd attempt. - Two hosts on the same driver have independent breakers — dead-host trips its breaker but live-host's first call still succeeds. Propagation tests: - ModbusDriverTests: SetPoint WriteIdempotent=true flows into DriverAttributeInfo; PulseCoil default=false. - S7DiscoveryAndSubscribeTests: same pattern for DBx SetPoint vs M-bit. Full solution dotnet test: 947 passing (baseline 906, +41 net across Stream A so far). Pre-existing Client.CLI Subscribe flake unchanged. Stream A's remaining work (wiring CapabilityInvoker into DriverNodeManager's OnReadValue / OnWriteValue / History / Subscribe dispatch paths) is the server-side integration piece + needs DI wiring for the pipeline builder — lands in the next PR on this branch. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
058c3dddd3 |
Phase 3 PR 21 — Modbus TCP driver: first native-protocol greenfield for v2. New src/Driver.Modbus project with ModbusDriver implementing IDriver + ITagDiscovery + IReadable + IWritable. Validates the driver-agnostic abstractions (IAddressSpaceBuilder, DriverAttributeInfo, DataValueSnapshot, WriteRequest/WriteResult) generalize beyond Galaxy — nothing Galaxy-specific is used here. ModbusDriverOptions carries Host/Port/UnitId/Timeout + a pre-declared tag list (Modbus has no discovery protocol — tags are configuration). IModbusTransport abstracts the socket layer so tests swap in-memory fakes; concrete ModbusTcpTransport speaks the MBAP ADU (TxId + Protocol=0 + Length + UnitId + PDU) over TcpClient, serializes requests through a semaphore for single-flight in-order responses, validates the response TxId matches, surfaces server exception PDUs as ModbusException with function code + exception code. DiscoverAsync streams one folder per driver with a BaseDataVariable per tag + DriverAttributeInfo that flags writable tags as SecurityClassification.Operate vs ViewOnly for read-only regions. ReadAsync routes per-tag by ModbusRegion: FC01 for Coils, FC02 for DiscreteInputs, FC03 for HoldingRegisters, FC04 for InputRegisters; register values decoded through System.Buffers.Binary.BinaryPrimitives (BigEndian for single-register Int16/UInt16 + two-register Int32/UInt32/Float32 per standard modbus word-swap conventions). WriteAsync uses FC05 (Write Single Coil with 0xFF00/0x0000 encoding) for booleans, FC06 (Write Single Register) for 16-bit types, FC16 (Write Multiple Registers) for 32-bit types. Unknown tag → BadNodeIdUnknown; write to InputRegister or DiscreteInput or Writable=false tag → BadNotWritable; exception during transport → BadInternalError + driver health Degraded. Subscriptions + Historian + Alarms deliberately out of scope — Modbus has no push model (subscribe would be a polling overlay, additive PR) and no history/alarm semantics at the protocol level. Tests (9 new ModbusDriverTests): InitializeAsync connects + populates the tag map + sets health=Healthy; Read Int16 from HoldingRegister returns BigEndian value; Read Float32 spans two registers BigEndian (IEEE 754 single for 25.5f round-trips exactly); Read Coil returns boolean from the bit-packed response; unknown tag name returns BadNodeIdUnknown without an exception; Write UInt16 round-trips via FC06; Write Float32 uses FC16 (two-register write verified by decoding back through the fake register bank); Write to InputRegister returns BadNotWritable; Discover streams one folder + one variable per tag with correct DriverDataType mapping (Int16/Int32→Int32, UInt16/UInt32→Int32, Float32→Float32, Bool→Boolean). FakeTransport simulates a 256-register/256-coil bank + implements the 7 function codes the driver uses. slnx updated with the new src + tests entries. Full solution post-add: 0 errors, 189 tests pass (9 Modbus + 180 pre-existing). IDriver abstraction validated against a fundamentally different protocol — Modbus TCP has no AlarmExtension, no ScanState, no IPC boundary, no historian, no LDAP — and the same builder/reader/writer contract plugged straight in. Future PRs on this driver: ISubscribable via a polling loop, IHostConnectivityProbe for dead-device detection, PLC-specific data-type extensions (Int64/BCD/string-in-registers).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |