cb7b81a87a Phase 3 PR 30 — Modbus integration-test project scaffold. New tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests project is the harness modbus-test-plan.md called for: a skip-when-unreachable fixture that TCP-probes a Modbus simulator endpoint (MODBUS_SIM_ENDPOINT, default localhost:502) once per test session, a DL205 device profile stub (single writable holding register at address 100, probe disabled to avoid racing with assertions), and one happy-path smoke test that initializes the real ModbusDriver + real ModbusTcpTransport, writes a known Int16 value, reads it back, and asserts status=0 + value round-trip. No DL205 quirk assertions yet — those land one-per-PR as the user validates each behavior in ModbusPal (word order for 32-bit, register-zero access, coil addressing base, max registers per FC03, response framing under load, exception code on protected-bit coil write).
ModbusSimulatorFixture is a collection fixture so the 2s TCP probe runs once per run, not per test; SkipReason gets a clear operator-facing message ('start ModbusPal or override MODBUS_SIM_ENDPOINT'). Tests call Assert.Skip(sim.SkipReason) rather than silently returning — matches the test-plan convention and reads cleanly in CI logs. DL205Profile.BuildOptions deliberately disables the background probe loop since integration tests drive reads explicitly and the probe would race with assertions. Tag naming uses the DL205_ prefix so filter 'DisplayName~DL205' surfaces device-specific failures at a glance.
Project references: xunit.v3 + Shouldly + Microsoft.NET.Test.Sdk + xunit.runner.visualstudio (matches the existing Driver.Modbus.Tests unit project), project ref to src/Driver.Modbus. Registered in ZB.MOM.WW.OtOpcUa.slnx under tests/. ModbusPal/README.md documents the dev loop (install ModbusPal jar, load profile, start simulator, dotnet test), explains MODBUS_SIM_ENDPOINT override for real-PLC benchwork, and flags DL205.xmpp as the first profile to add in a follow-up PR.
dotnet test run against the scaffold (no simulator running) skips cleanly: 0 failed, 0 passed, 1 skipped, with the SkipReason surfaced. dotnet build clean (0 warnings, 0 errors). Updated docs/v2/modbus-test-plan.md to mark the scaffold PR done and renumbered future PRs from 'PR 27+' to 'PR 31+' to stay in sync with the actual PR chain.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-18 15:02:39 -04:00
Joseph Doherty
77d09bf64e Phase 3 PR 25 — modbus-test-plan.md: integration-test playbook with per-device quirk catalog. ModbusPal is the chosen simulator; AutomationDirect DL205 is the first target device class with 6 pending quirks to document and cover with named tests (word order for 32-bit values, register-zero access policy, coil addressing base, maximum registers per FC03, response framing under sustained load, exception code on protected-bit coil write). Each quirk placeholder has a proposed test name so the user's validation work translates directly into integration tests. Test conventions section codifies the named-per-quirk pattern, skip-when-unreachable guard, real ModbusTcpTransport usage, and inter-test isolation. Sets up the harness-and-catalog structure future device families (Allen-Bradley Micrologix, Siemens S7-1200 Modbus gateway, Schneider M340, whatever the user hits) will slot into — same per-device catalog shape, cross-device patterns section for recurring quirks that can get promoted into driver defaults. Next concrete PRs proposed: PR 26 for the integration test project scaffold + DL205 profile + fixture with skip-guard + one smoke test, PR 27+ for the individual confirmed quirks one-per-PR.