Joseph Doherty 09e0fe1841 fix(focas): a returned status never ends a device's batch; round-2 minors (#740 review round 2)
N1: linkDown is set only when NO reply arrived, i.e. a timeout, a transport exception or
a connect failure. A status the CNC returned proves it answered. EW_REJECT and every
unlisted rc map to BadCommunicationError, so a deterministic rc on one tag used to fail
every later tag of a reachable control on every poll. The comms-classed status still
degrades health. The coalescer already treated a returned refusal this way; it is
unchanged.

Tests: a returned EW_REJECT on tag 1 leaves tags 2 and 3 read and Good (red before). A
timeout still fails the rest without reading them (positive control).

Minors:
- m1: the _lifecycleLock doc now covers the health transitions it also guards.
- m2: the NoteFixedTreeFailed summary says a refusal credits the answer.
- m3: ReadAsync stamps a failed batch's exception with the generation the batch started
  under, and HandlePollError degrades that generation only.
- m4: the fixed-tree "blip" absence check runs unconditionally under a wide budget, and
  asserts that both ticks landed inside it.
- m5: direct unit cases for the coalescer link-down paths. A transport fault on the first
  range fails the second range and the per-tag tag without reading them. A connect
  failure costs one connect per batch. CncRelay.Up() retries the re-bind.

Refs #740
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 14:55:37 -04:00
Joseph Doherty fd64fed217 fix(focas): a stalled device fails fast for the rest of its batch; generation-stamp health (#740 review round 1)
I1: Task.WhenAll waits for the slowest device, so concurrency alone still let a device
that accepts TCP and then stalls cost (its tag count x call timeout) per batch. After the
first timeout, transport failure or comms-class status on a device, its remaining tags in
the batch now fail BadCommunicationError immediately, the same as the coalescer's
FailMembers, which now also stops after a failed range. FIXED: tags are still served
from the cache. A malformed address is BadNodeIdUnknown and does not count as a link
failure. Test: a 10-tag stalled device beside a healthy one completes in under 3 call
timeouts with the healthy value Good. The P9 test now also asserts per-client read
counts and that two reads overlapped across devices.

Minors:
- 1: a superseded init releases its table only if it was never published (flag).
- 2: a fixed-tree refusal credits LastSuccessfulRead; a value-path refusal after a comms
  fault restores Healthy.
- 5: alarm/fixed/refusal health is reset inside the publish lock, after the generation
  check.
- 6: FocasFixedTreeHealthTests wait on served-failure/refusal counters, not wall-clock.
- 8: data-path health writes (reads, coalescer, writes, poll errors, refusals) carry the
  generation they started under and are dropped once a lifecycle call has moved on. Each
  write is a check-and-set under the lifecycle lock.
Also adds a unit case where 20 vendor records with type 0 and empty messages stay vendor.

Refs #740
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 14:44:42 -04:00
Joseph Doherty 256915b7e4 perf(focas): read devices concurrently within a batch (R07:P9)
ReadAsync walked the whole batch sequentially, so one SLOW CNC (TCP-accept-then-stall,
the live 31i-B case) cost Timeout per tag per poll while no other device was read.
ReadAsync now resolves every reference against one table snapshot, buckets the rest by
device and reads the devices with Task.WhenAll; each device's tags still go in order on
its own serialised socket (the PMC coalescing pre-pass runs per device, first). Results
land at their own indices.

Also precomputes each device's fixed-tree key prefix (it was built per reference, twice
per poll).

Refs #740
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT