Five drivers ignored the config handed to them on reinitialize, serving the
options their constructor captured — and the deployment sealed green anyway.
Fixed on both halves, as chosen.
Seam (load-bearing): DriverSpawnPlanner routes a changed DriverConfig to
ToStop + ToSpawn instead of an in-place delta, making the factory the single
parse authority. This REVERSES the deliberate decision documented at
DriverSpawnPlan.cs:49-50 ("a pure DriverConfig change stays an in-place delta
— no reconnect"). That reasoning was correct about the resilience pipeline and
wrong about the driver. The accepted price is a reconnect per config edit.
Per-driver, and this split was not anticipated:
- Re-parse in place — Modbus, AbLegacy, OpcUaClient. ParseOptions extracted
from each factory, called from InitializeAsync behind a HasConfigBody guard
so "{}" still keeps the constructor options.
- Respawn-only, deliberately NOT re-parsed — Sql and FOCAS. Each builds more
than options from config (Sql's dialect + resolved connection string,
FOCAS's client-factory backend, both injected at construction), so adopting
new options alone would run a NEW tag set against an OLD connection. Half a
re-parse is worse than none. SqlDriver's doc-comment asserted the opposite
premise — "config parsing belongs to the factory, which builds a fresh
instance" — which was false when written and is true only now.
Two green seals removed from ApplyChildDelta: it overwrote the cached Spec
synchronously BEFORE the child dequeued the message, so the host believed the
new config was live and the next reconcile computed no delta, sealing the
drift permanently; and it Tell'd with no Receive<ApplyResult> registered, so a
failed reinit — including Galaxy's deliberate NotSupportedException —
dead-lettered.
Exposed (not created) by the change: a factory throw is a CONFIG error, and
SpawnChild catches it and silently substitutes a stub. Only a brand-new driver
could reach that before; an ordinary config edit can now. Raised Warning ->
Error with an actionable message. It still does not fail the deployment —
doing so would let one malformed driver block a fleet deploy, so that is a
follow-up rather than a drive-by.
Tests: every pre-existing reinit test in these suites passes "{}", the exact
input a guarded re-parser treats as "keep constructor options" — blind to this
defect by construction. New tests pass CHANGED json; the Modbus one was
verified falsifiable by deleting the re-parse (goes red). Two tests asserted
the old behaviour and were rewritten, including the positive control in
DriverHostActorUnreadableArtifactTests, whose observable moved from
UnsubscribeAsync to ShutdownAsync now that teardown happens by stopping the
child rather than emptying its desired set.
Remaining full-suite failures are pre-existing and environmental, verified
identical on the pre-change tree: Host.IntegrationTests (3) and
Driver.AbLegacy.IntegrationTests (4, docker fixture-gated).
Follow-ups from the fleet-wide read-timeout audit that the S7 R2-01 read-leg
fix (PR #453) prompted. The audit confirmed S7 was the ONLY driver with the
async-read-ignores-socket-timeout hang; these are the two adjacent (non-hang)
findings it surfaced.
1. FOCAS TimeoutMs:0 footgun (the risky one): a non-positive Timeout made
SynchronizedFocasClient DISABLE its per-call wall-clock ceiling, reverting to
the caller's long-lived poll token — reintroducing exactly the frozen-peer
wedge S7 just eliminated, under misconfig. Clamp non-positive TimeoutMs to the
2s default at the config boundary so the deadline can never be authored away.
2. TimeoutMs validation symmetry: apply the same clamp in the AbCip + AbLegacy
factories. libplctag's Tag.Timeout setter throws on <=0, faulting tag creation
on every read/write; clamping keeps a misconfigured TimeoutMs:0 running on the
default bound instead. (Shared PositiveTimeoutOrDefault helper per factory.)
3. AbLegacy reconnect parity with AbCip: AbLegacy evicted the cached libplctag
runtime on neither the non-zero-status nor transport-exception read/write path
(AbCip evicts on both), so a data-path fault recovered only via the probe loop
/ libplctag internals. Added EvictRuntime + wired it into both read and write
failure paths so a fresh handle is created on the next call.
Tests: FOCAS 265->269 (clamp theory + positive), AbCip 336->339 (clamp theory +
positive), AbLegacy 209->212 (read-nonzero / read-exception / write-nonzero evict).
No production regressions; all three driver suites green.
Adds <summary>/<param>/<returns>/<inheritdoc> where missing and removes
project bookkeeping IDs (task/tracking refs) from shipped code comments,
so the docs read cleanly and CommentChecker is quiet except for known
false positives (PLC/protocol terms, event/IEqualityComparer inheritdoc).
Doc/comment-only; no logic changed; solution builds clean.
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public
members surfaced by commentchecker — resolves 5,847 of 5,869 issues
(99.6%) across three /fixdocs passes.
- Driver.AbLegacy-005: optional ILogger<AbLegacyDriver> ctor parameter,
logged init failure / probe transitions / first non-zero libplctag
status per device.
- Driver.AbLegacy-011: Dispose() runs the synchronous teardown directly
instead of bridging via DisposeAsync().AsTask().GetAwaiter().GetResult()
to remove the documented sync-over-async deadlock pattern.
- Driver.AbLegacy-013: documented the ResolveHost three-tier fallback
chain in XML and pointed DiscoverAsync's IsArray=false comment at the
Modbus ArrayCount pattern for the eventual multi-element follow-up.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.
- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
integration, install).
Build green (0 errors); unit tests pass. Docs left for a separate pass.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>