Commit Graph

3 Commits

Author SHA1 Message Date
Joseph Doherty
58a0cccc67 AB CIP Logix Emulate golden-box tier — scaffold the code + docs so the L5X + Emulate PC drop in without fixture-code changes. Closes the initial design question the user raised; the actual Emulate-side work (author project, commit L5X, install Emulate on the dev box) is tracked as #223. Scaffolding ships everything that doesn't need the live Emulate instance: tier-gated test classes that skip cleanly when AB_SERVER_PROFILE is unset, the profile gate helper, the LogixProject/README.md documenting the exact project state the tests expect, the fixture coverage doc's new §Logix Emulate tier section with the when-to-trust table extended from 3 columns to 4, and the dev-environment.md integration-host row.
AbServerProfileGate — static helper that reads `AB_SERVER_PROFILE` env var (defaults to "abserver") + exposes `SkipUnless(params string[] requiredProfiles)` matching the MODBUS_SIM_PROFILE pattern the DL205StringQuirkTests uses one directory over. Emulate-only tests call `AbServerProfileGate.SkipUnless("emulate")` at the top of each fact body; ab_server-default runs see them skip with a clear message pointing at the Emulate setup steps.

AbCipEmulateUdtReadTests — one test proving the #194 whole-UDT read optimization works against the real Logix Template Object, not just the golden byte buffers the unit suite uses. Builds an `AbCipDriverOptions` with a Structure tag `Motor1 : Motor_UDT` that has three declared members (Speed : DINT, Torque : REAL, Status : DINT), reads them via the `.Speed / .Torque / .Status` dotted-tag syntax, asserts the driver gets the grouped whole-UDT path + decodes each at the right offset. Required seed values documented inline + in LogixProject/README.md: Speed=1800, Torque=42.5f, Status=0x0001.

AbCipEmulateAlmdTests — one test proving the #177 ALMD projection fires `OnAlarmEvent` when a real ALMD instruction's `In` edge rises, not just the fake `InFaulted` timer edges the unit suite drives. Needs a `SimulateAlarm : BOOL` tag routed through `MainRoutine` ladder (`XIC SimulateAlarm OTE HighTempAlarm.In`) so the test case can pulse the input via the existing `IWritable.WriteAsync` path instead of scripting Emulate via its own socket. Alarm-projection options carry `EnableAlarmProjection = true` + 200 ms poll interval; a `TaskCompletionSource` gates the raise-event assertion with a 5 s deadline. Cleanup writes SimulateAlarm=false so consecutive runs start from known state.

LogixProject/README.md — the Studio 5000 project state the Emulate-tier tests depend on. Explains why L5X over ACD (text diff, reproducible import, no per-install state), the UDT + tag + routine structure, how to bring it up on the Emulate PC. Ships as a stub pending actual author + L5X export + commit; the README itself keeps the requirements visible so the L5X author has a checklist.

docs/drivers/AbServer-Test-Fixture.md — new §Logix Emulate golden-box tier section with the coverage-promotion table (ab_server / Emulate / hardware per gap), the setup-env-var recipe, the costs to accept (license, Hyper-V conflict, manual lifecycle). "When to trust" table extended from 3 columns (ab_server / unit / rig) to 4 (ab_server / unit / Logix Emulate / rig); two new rows for EtherNet/IP embedded-switch + redundant-chassis failover that even Emulate can't help with. Follow-up candidates list gets Logix Emulate as option 1 ahead of the pre-existing "extend ab_server upstream" + "stand up a lab rig". See-also file list gains AbServerProfileGate.cs + Docker/ + Emulate/ + LogixProject/README.md entries.

docs/v2/dev-environment.md — §C Integration host gains a Rockwell Studio 5000 Logix Emulate row: purpose (AB CIP golden-box tier closing UDT/ALMD/AOI/safety/ConnectionSize gaps), type (Windows-only, Hyper-V conflict matching TwinCAT XAR's constraint), port 44818, credentials note, owner split between integration-host admin for license+install and developer for per-session runtime start.

Verified: Emulate tests skip cleanly when AB_SERVER_PROFILE is unset — both `[SKIP]` with the operator-facing message pointing at the env-var setup. Whole-solution build 0 errors. Tests will transition from skip → pass once the L5X + Emulate PC land per #223.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-20 12:54:39 -04:00
Joseph Doherty
6609141493 Dockerize Modbus + AB CIP + S7 test fixtures for reproducibility. Every driver integration simulator now has a pinned Docker image alongside the existing native launcher — Docker is the primary path, native fallbacks kept for contributors who prefer them. Matches the already-Dockerized OpcUaClient/opc-plc pattern from #215 so every fixture in the fleet presents the same compose-up/test/compose-down loop. Reproducibility gain: what used to require a local pip/Python install (Modbus pymodbus, S7 python-snap7) or a per-OS C build from source (AB CIP ab_server from libplctag) now collapses to a Dockerfile + docker compose up. Modbus — new tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Docker/ with Dockerfile (python:3.12-slim-bookworm + pymodbus[simulator]==3.13.0) + docker-compose.yml with four compose profiles (standard / dl205 / mitsubishi / s7_1500) backed by the existing profile JSONs copied under Docker/profiles/ as canonical; native fallback in Pymodbus/ retained with the same JSON set (symlink-equivalent — manual re-sync when profiles change, noted in both READMEs). Port 5020 unchanged so MODBUS_SIM_ENDPOINT + ModbusSimulatorFixture work without code change. Dropped the --no_http CLI arg the old serve.ps1 + compose draft passed — pymodbus 3.13 doesn't recognize it; the simulator's http ui just binds inside the container where nothing maps it out and costs nothing. S7 — new tests/ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests/Docker/ with Dockerfile (python:3.12-slim-bookworm + python-snap7>=2.0) + docker-compose.yml with one s7_1500 compose profile; copies the existing server.py shim + s7_1500.json seed profile; runs python -u server.py ... --port 1102. Native fallback in PythonSnap7/ retained. Port 1102 unchanged. AB CIP — hardest because ab_server is a source-only C tool in libplctag's src/tools/ab_server/. New tests/ZB.MOM.WW.OtOpcUa.Driver.AbCip.IntegrationTests/Docker/ Dockerfile is multi-stage: build stage (debian:bookworm-slim + build-essential + cmake) clones libplctag at a pinned tag + cmake --build build --target ab_server; runtime stage (debian:bookworm-slim) copies just the binary from /src/build/bin_dist/ab_server. docker-compose.yml ships four compose profiles (controllogix / compactlogix / micro800 / guardlogix) with per-family ab_server CLI args matching AbServerProfile.cs. AbServerFixture updated: tries TCP probe on 127.0.0.1:44818 first (Docker path) + spawns the native binary only as fallback when no listener is there. AB_SERVER_ENDPOINT env var supported for pointing at a real PLC. AbServerFact/Theory attributes updated to IsServerAvailable() which accepts any of: live listener on 44818, AB_SERVER_ENDPOINT set, or binary on PATH. Required two CLI-compat fixes to ab_server's argument expectations that the existing native profile never caught because it was never actually run at CI: --plc is case-sensitive (ControlLogix not controllogix), CIP tags need [size] bracket notation (DINT[1] not bare DINT), ControlLogix also requires --path=1,0. Compose files carry the corrected flags; the existing native-path AbServerProfile.cs was never invoked in practice so we don't rewrite it here. Micro800 now uses the --plc=Micro800 mode rather than falling back to ControlLogix emulation — ab_server does have the dedicated mode, the old Notes saying otherwise were wrong. Updated docs: three fixture coverage docs (Modbus-Test-Fixture.md, S7-Test-Fixture.md, AbServer-Test-Fixture.md) flip their "What the fixture is" section from native-only to Docker-primary-with-native-fallback; dev-environment.md §Resource Inventory replaces the old ambiguous "Docker Desktop + ab_server native" mix with four per-driver rows (each listing the image, compose file, compose profiles, port, credentials) + a new Docker fixtures — quick reference subsection giving the one-line docker compose -f <…> --profile <…> up for each driver + the env-var override names + the native fallback install recipes. drivers/README.md coverage map table updated — Modbus/AB CIP/S7 entries now read "Dockerized …" consistent with OpcUaClient's line. Verified end-to-end against live containers: Modbus DL205 smoke 1/1, S7 3/3, AB CIP ControlLogix 4/4 (all family theory rows). Container lifecycle clean (up/test/down, no leaked state). Every fixture keeps its skip-when-absent probe + env-var endpoint override so dotnet test on a fresh clone without Docker running still gets a green run.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-20 12:09:44 -04:00
Joseph Doherty
cc35c77d64 AB CIP PR 3 — IReadable implementation against libplctag. Introduces IAbCipTagRuntime + IAbCipTagFactory abstraction matching the Modbus transport-factory pattern (ctor optional arg, default production impl injected) so the driver's read/status-mapping logic is unit-testable without a live PLC or the native libplctag binary. LibplctagTagRuntime is the default wire-backed implementation — wraps libplctag.Tag + translates our AbCipDataType enum into GetInt8/GetUInt8/GetInt16/GetUInt16/GetInt32/GetUInt32/GetInt64/GetUInt64/GetFloat32/GetFloat64/GetString/GetBit calls covering Bool (standalone + BOOL-in-DINT via .N bit selector), SInt/USInt, Int/UInt, DInt/UDInt, LInt/ULInt, Real, LReal, String, Dt (epoch DINT), with Structure deferred to PR 6. MapPlcType bridges our libplctag attribute strings (controllogix, compactlogix, micro800) to libplctag.PlcType enum; CompactLogix rolls under ControlLogix per libplctag's family grouping which matches the wire protocol reality. AbCipDriver now implements IReadable — ReadAsync iterates fullReferences preserving order, looks up each tag definition + its device, lazily materialises the tag runtime via EnsureTagRuntimeAsync on first touch (cached thereafter for the lifetime of the device), catches OperationCanceledException to honor cancellation, maps libplctag non-zero status via AbCipStatusMapper.MapLibplctagStatus, catches any other exception as BadCommunicationError. Health surface moves to Healthy on success + Degraded with the last error message on failure. Initialize-failure path disposes the half-created runtime before rethrowing so no native handles leak. DeviceState gains a Runtimes dict alongside the existing TagHandles collection; DisposeHandles walks both so ShutdownAsync + ReinitializeAsync cleanly destroy every native tag. 12 new unit tests in AbCipDriverReadTests using FakeAbCipTag / FakeAbCipTagFactory (test fake under tests/...AbCip.Tests/FakeAbCipTag.cs) covering unknown reference → BadNodeIdUnknown, unknown device → BadNodeIdUnknown, successful DInt read with correct Good status + captured value, lazy-init on first read with reuse across subsequent reads, non-zero libplctag status mapping via AbCipStatusMapper, exception during read surfacing as BadCommunicationError with health Degraded, batched reads preserving order + per-tag status, health Healthy after success, TagCreateParams composition from device + profile (gateway / port / CIP path / libplctag attribute / tag name wiring), cancellation propagation via OperationCanceledException, ShutdownAsync disposing every runtime, Initialize-failure disposing the aborted runtime. Total AbCip unit tests now 88/88 passing. Integration test project scaffolding — tests/ZB.MOM.WW.OtOpcUa.Driver.AbCip.IntegrationTests with AbServerFixture (IAsyncLifetime that starts ab_server when the binary is on PATH, otherwise marks IsAvailable=false), AbServerFact attribute (Fact-equivalent that skips when ab_server is missing), one smoke test exercising DInt read end-to-end. Project runs cleanly — the single smoke test skips on boxes without ab_server (0 failed, 0 passed, 1 skipped) + runs on boxes with it. Follow-up work captured in comments — ab_server CI fixture (download prebuilt Windows x64 binary as GitHub release asset) + per-family JSON profiles + hand-rolled CIP stub for UDT fidelity ship in the PR 6/9-12 window. Solution file updated. Full solution builds 0 errors across all 28 projects. Modbus + other existing tests untouched.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 16:38:54 -04:00