Completes data-plane enforcement behind Security:Acl:Enabled. Read (every
attribute, not just Value), Browse, TranslateBrowsePath, CreateMonitoredItems,
SubscribeToEvents and SetMonitoringMode now consult scoped NodeAcl grants.
With the flag off nothing changes.
Four things went beyond the stage as written, each because leaving it out
would have made the feature look like it worked:
- Browse needed ancestor visibility. The trie inherits downward, and a client
reaches a deep node by browsing the nodes above it, so without this every
grant narrower than the cluster was authored, shipped and unreachable. It is
a separate non-inheriting marker, NOT a synthesized Browse grant on each
ancestor: the additive downward walk would carry such a grant from Plant onto
Plant/Siemens/dev9 and every other sibling subtree. Pinned by a test that
goes through the evaluator — probing the trie helper directly passes against
the broken design, because a sibling is absent from the trie either way.
- Revocation had to reach LIVE subscriptions. Every other operation re-asks per
request; a subscription is authorized once and then streams, and streaming is
how machine consumers actually read this server — so stopping only the
re-asking operations would have made revocation close to cosmetic.
IDataPlaneAuthoritySource gained a Changed event.
A denied item is queued BadUserAccessDenied and then DETACHED from its
MonitoredNode2 fan-out, not set MonitoringMode.Disabled. Disabling discards
the item's queued notifications, so the client is silenced without ever being
told why. The over-the-wire test caught this; the unit-level path reports the
item as stood down either way. Detaching is also reversible, so a restored
grant resumes the feed with no client action.
- The decision cache holds the grant WALK, not the decision. Grants and the
trie are fixed for a generation; a key's ExpiresUtc passes with the clock, so
caching the whole decision would let an expired key keep working until the
next deploy — the stage-5 open-session hole in a subtler form.
- TranslateBrowsePath is gated, without which browse filtering is decorative: a
client refused a browse asks TranslateBrowsePathsToNodeIds for the same path.
Found en route: UserAuthorizationState's staleness ceiling couples two clocks.
MembershipResolvedUtc is stamped from DataPlaneAuthorizer's TimeProvider while
IsStale is evaluated against TriePermissionEvaluator's; they are the same
instance in production and diverge the moment anything injects a test clock, at
which point the evaluator denies EVERYTHING with a verdict indistinguishable
from "no grant matched". Stage 5's claim that these predicates cannot fire was
accidentally true; they are now disabled explicitly.
Also fixed: ContinuationPoint.NodeToBrowse is the manager HANDLE, not a
NodeState. The declared type is object, so the wrong cast compiled cleanly and
silently yielded null — skipping the browse source gate entirely.
Falsified: disabling the transit marking reddens exactly the three tests that
assert transit works; implementing transit as an ancestor grant reddens the
sibling-leak test; skipping the fan-out detach reddens the revocation test.
Full solution suite green.
The stage 8 live gate has NOT run yet.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
#519 — a driver's OPC UA status code now reaches a client with its sub-code intact.
DriverInstanceActor projected the driver's uint onto a 3-state Good/Uncertain/Bad enum
and OtOpcUaNodeManager re-expanded Bad to a bare 0x80000000, so BadNoCommunication,
BadTypeMismatch and BadNotSupported were indistinguishable on the wire and every
driver's status constants (incl. the 16 #497 had just corrected) were diagnostic in
logs only. Resolved by option (b): the raw uint rides AttributeValuePublished ->
AttributeValueUpdate -> IOpcUaAddressSpaceSink.WriteValue, OpcUaQuality is deleted, and
severity classification is a helper (OpcUaStatus.IsGood/IsUncertain/IsBad).
The surface was wider than the issue costed (41 files, not "the sink and 3
implementations"): OpcUaQuality had non-driver producers with no uint to carry.
Each got its natural code — BadInternalError for a failed virtual-tag script,
BadNoCommunication for driver comms loss — and ScriptedAlarmHostActor's pair of
mutually-inverse uint<->enum mappers is deleted, having round-tripped a code the
engine already held. AddressSpaceApplier's removal writes deliberately keep the
generic Bad: not losing a code the driver had is this issue; inventing one for the
deploy path is a separate call.
Behaviour change: WriteAlarmQuality fires its Part 9 event on a status-code change
rather than a severity-bucket change. While the annotation was 3-state those were the
same predicate; now a move between two Bad reasons changes what a subscriber reads.
New SDK-free named constants live on Commons.OpcUa.OpcUaStatus, and
StatusCodeParityTests is widened to cover them — that guard is reflection-driven, so
it can only see a named constant, never an inline literal.
#517 — the symptom is real but the issue named the wrong path and its fix was unsafe.
ShutdownAsync cannot race: DriverInstanceActor calls it from PostStop, after the
mailbox drains. (Core/Hosting/DriverHost, the one class with a concurrent GetHealth,
has no production call site.) InitializeAsync can: it runs on a fire-and-forget
Task.Run, and MTConnectDriver writes Healthy then starts loops that can throw into a
catch which disposes the client before writing Faulted.
Moving the write earlier, as suggested, inverts the terminal state — teardown drains
in-flight loops that write health as they unwind, so a late loop could leave Healthy at
rest with every connection closed. The fix is a bracket (conservative before, terminal
after), applied to MTConnect's init-failure path only; shutdown keeps its single
trailing write, and the rule plus the reachability table are documented on
IDriver.ShutdownAsync.
CalculationDriver.GetHealth returned a hard-coded Healthy that consulted nothing —
Healthy before initialize, after shutdown and after dispose. Now derived from _running.
Its test, named Health_is_always_Connected, asserted the defect and is replaced.
Every new guard was falsified by breaking the production code and watching it go red.
The two sub-code tests each assert two different Bad codes, since a single-code
assertion could pass against a hard-coded constant under the old projection.
Pre-existing failures, verified unchanged on a stashed tree and not chased: 4 in
Driver.AbLegacy.IntegrationTests (slc500/micrologix/plc5 fixtures not up) and 3 in
Host.IntegrationTests.
Closes#517Closes#519
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
Part 9 ConditionType.Quality was never assigned; default(StatusCode)==Good
so every native + scripted condition reported Good unconditionally — a
comms-lost device still showed a healthy, inactive, Good condition (a
wrong-VALUE bug, distinct from the null-value #473/#475). Clients (and HMIs
bucketing on IsGood) could not tell "genuinely inactive" from "lost contact".
Layer 1 — make Quality a real, plumbed field:
- AlarmConditionSnapshot gains OpcUaQuality Quality (default Good).
- MaterialiseAlarmCondition sets it (native BadWaitingForInitialData, scripted Good).
- WriteAlarmCondition projects snapshot.Quality; the delta-gate gains a Quality
member so a quality-bucket change fires a Part 9 event.
Layer 2 — drive native quality from driver connectivity (a comms-lost driver
emits no alarm transitions, and an alarm-bearing raw tag has no value variable,
so quality can't come from either existing channel):
- DriverInstanceActor Tells parent ConnectivityChanged on Connected/Reconnecting.
- DriverHostActor fans it to every native condition the driver owns as
OpcUaPublishActor.AlarmQualityUpdate (Good on connect, Bad on disconnect).
- New dedicated IOpcUaAddressSpaceSink.WriteAlarmQuality sets ONLY Quality and
fires only on a bucket change — never touches Active/Acked/Retain (an active
alarm that loses comms stays active). Not a full-snapshot re-projection, so it
can't clobber severity/message and works for a never-fired condition.
Forwarded through DeferredAddressSpaceSink (F10b trap; auto-verified by the
reflection forwarding guard). Ungated by redundancy role; no /alerts row.
Scripted conditions stay Good; worst-of-input quality deferred to #478 (Layer 3).
Tests: node-level (materialise/project/no-clobber/unknown-node no-op),
NativeAlarmProjector, DriverInstanceActor connectivity emission, DriverHostActor
fan-out, OpcUaPublishActor routing, and the wire-level guard
(Condition_event_Quality_tracks_source_connectivity_on_the_wire) — RED-verified
against a simulated pre-fix always-Good server. Existing DriverInstanceActor
parent probes ignore the new ConnectivityChanged.
Docs: docs/AlarmTracking.md §"Condition source-data Quality (#477)";
design doc docs/plans/2026-07-17-alarm-condition-quality-477-design.md.
MaterialiseAlarmCondition never assigned the mandatory Part 9 ConditionType
classification fields, so every condition event — native and scripted — shipped
ConditionClassId = NodeId.Null (i=0) and ConditionClassName = empty text. Same
mechanism as #473: Create() builds the mandatory children from the type's
embedded definition but leaves them unset, and nothing downstream synthesises
them (ReportEvent / InstanceStateSnapshot copy children verbatim). An HMI
bucketing alarms by condition class dropped every OtOpcUa alarm as unclassified.
Report BaseConditionClassType — Part 9's "no condition class modelled" value.
This is the honest report: we hold no classification at the materialise seam.
Deliberately NOT ProcessConditionClassType (the SDK sample's pick), which would
assert a classification we cannot back and would be actively wrong for a Galaxy
alarm whose upstream category is Safety/Diagnostics — trading a detectable null
for an undetectable lie. Real per-alarm classification needs the driver's
AlarmCategory carried to this deploy-time seam (it lives only on the runtime
AlarmEventArgs transition today) and is a separate feature.
Guards, both observed RED against the pre-fix server:
- NativeAlarmEventIdentityFieldDeliveryTests: wire-level, its own select clause
(the #473 test's clause mirrors ScadaBridge's exactly and its indices are
load-bearing, so it is left untouched). The class fields are declared on
ConditionType, not BaseEventType, so they are selected against that type.
- NodeManagerAlarmSourceFieldsTests: node-level, native (Raw) + scripted (Uns).
Stacked on #473 (PR #474) — merge after it.
MaterialiseAlarmCondition never assigned the three mandatory BaseEventType
identity fields, so all three arrived null on every condition event — native
and scripted. The SDK does not synthesise them on this path: Create() builds
the children from the type definition but leaves them unset, the auto-filling
BaseEventState.Initialize overload is only used for transient events, and
ReportEvent / InstanceStateSnapshot copy children verbatim. A conforming
client could not attribute an alarm to its source.
EventType = the concrete materialised type (TypeDefinitionId)
SourceNode = the condition's own NodeId (== ConditionId) — the condition IS
the source; an alarm-bearing raw tag materialises only the
condition, with no sibling value variable
SourceName = the same identifying id string: RawPath (native) /
ScriptedAlarmId (scripted)
SourceName carries the unique id rather than the leaf name: the leaf collides
across devices (HR200 on two PLCs) and is already carried by ConditionName, so
nothing is lost. Documented in docs/AlarmTracking.md, including that clients
must key on ConditionId and must not compose SourceName with ConditionName,
and that SourceName is NOT a live<->history join key (the alarm-history writer
stamps it with the EquipmentPath — a pre-existing divergence, now called out).
Tests: NativeAlarmEventIdentityFieldDeliveryTests is the wire-level guard —
a real client subscription using the standard [EventType, SourceNode,
SourceName, Time, Message, Severity] select clause, verified to fail against
the pre-fix server. NodeManagerAlarmSourceFieldsTests guards the node across
both realms, the base-type fallback, and the kind-swap re-materialise.
The HistoryRead events projection is a separate path (it projects historian
rows, not node fields) and is unaffected — its EventType => Variant.Null
assertions still hold.
M1 — over-the-wire event-delivery proof (new NativeAlarmMultiNotifierEventDeliveryTests
in OpcUaServer.IntegrationTests): boots the real server, wires one condition to two
equipment folders, fires ONE transition, and asserts a Server-object subscriber gets
EXACTLY ONE event (the shared-InstanceStateSnapshot queue dedup), plus overlapping
Server + equipment-folder subscribers each get exactly one copy. Captures via the
subscription FastEventCallback keyed by ClientHandle (the per-item Notification/DequeueEvents
path delivers nothing for these conditions in the SDK client — the working capture is the
fast callback).
M2 — resolution-failure signal + path-agreement tripwire (AddressSpaceApplier): when a
native alarm HAS ReferencingEquipmentPaths but NONE resolve to an equipment folder, count
it as a failed node (degraded-apply meter) + LogWarning instead of a silent skip; documented
the DisplayName==Name coupling as a binding invariant. Tests:
Composer_referencing_equipment_paths_resolve_back_to_equipment_ids_in_the_applier (real
composer output → applier inversion) + ..._unresolvable_referencing_equipment_counts_as_failed.
M3 — WireAlarmNotifiers is now a RECONCILE (unwires a folder dropped from the supplied set,
bidirectionally) so a future surgical ChangedRawTags path can't leave a de-referenced
equipment receiving the alarm; binding guard comment added on the classifier's
ChangedRawTags→Rebuild branch. Test: WireAlarmNotifiers_reconciles_a_dropped_folder_out_of_the_notifier_set.
L1 — MaterialiseAlarmCondition's kind-swap drop-and-recreate now calls
UnwireAlarmNotifiers(conditionKey) before discarding the old instance (teardown symmetry).
L3 — BuildEquipmentIdByFolderPath LogWarnings on a duplicate Area/Line/Name collision
(defense-in-depth; UNS uniqueness prevents it).
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
Wave B of Batch 4 — the runtime binding seam for the dual namespace.
Applier (both realms, explicit realm at every sink call site):
- MaterialiseRawSubtree: Raw containers as folders + Raw tags as variables
keyed by RawPath (native-alarm tag → single Part 9 condition at the RawPath),
all in AddressSpaceRealm.Raw; historian tagname = override else RawPath.
- MaterialiseUnsReferences: each UNS reference Variable under its equipment
folder (Uns realm) + an Organizes UNS->Raw edge; inherits writable/array/
historian tagname from the backing raw tag (both NodeIds -> one tagname).
- FeedHistorizedRefs / ProvisionHistorizedTags now source RAW tags (mux ref
stays single, keyed by RawPath); ApplyPureRemove tears down raw tags + UNS
refs in place (raw-container removal falls back to rebuild).
DriverHostActor (dual-NodeId, single-source fan-out):
- _nodeIdByDriverRef value gains a realm (NodeRealmRef); rebuilt from
RawTags UNION UnsReferenceVariables so one (DriverInstanceId, RawPath) fans
to the raw NodeId AND every referencing UNS NodeId with identical
value/quality/timestamp. Write inverse map keyed by the bare id; the
ns-qualified NodeId the write hook passes is normalised (BareNodeId) so a
write to either NodeId resolves the same driver ref (-> RawPath write).
- Native raw alarm condition routing is realm-tagged (Raw); AttributeValueUpdate
+ AlarmStateUpdate carry the realm through to the sink.
Retire EquipmentNodeIds -> V3NodeIds.Uns (applier/VirtualTagHostActor) and
RawPaths.Combine (DiscoveredNodeMapper, discovered nodes are Raw now).
DeploymentArtifact.ParseComposition emits the Raw + UNS subtrees byte-parity
with the composer (reconstruct entities -> AddressSpaceComposer.Compose).
Sink surface: removed the transitional `= AddressSpaceRealm.Uns` defaults from
IOpcUaAddressSpaceSink / ISurgicalAddressSpaceSink / SdkAddressSpaceSink /
DeferredAddressSpaceSink / NullOpcUaAddressSpaceSink — every call site is now
explicit (realm reordered before the trailing optionals on EnsureVariable +
MaterialiseAlarmCondition). Node-manager convenience methods keep their
defaults (they are not the interface impl; Sdk delegates explicitly).
Tests: rewrote DriverHostActorLiveValueTests (fan-out drift, 1:N) +
DriverHostActorWriteRoutingTests (dual-NodeId raw/uns write routing) to the v3
raw+uns model; new AddressSpaceApplierRawUnsTests; migrated the EquipmentTags
provisioning/feed tests to RawTags; swept EquipmentNodeIds test callers.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
OpcUaServer.IntegrationTests was 4F. Two distinct, previously-masked issues:
1. Cert-store gap: the in-test client SecurityConfiguration used a bare
new SecurityConfiguration()/CertificateIdentifier(), so ValidateAsync threw
'TrustedIssuerCertificates StorePath must be specified' before any connect.
Added TestClientSecurity helper building Directory own/issuer/trusted/rejected
stores under a throwaway temp PKI dir (mirrors DefaultApplicationConfigurationFactory);
wired into DualEndpointTests + SubscriptionSurvivalTests.
2. Fixing #1 unmasked an SDK-version drift: the 1.5.378 node-cache read path
throws ServiceResultException(BadNodeIdUnknown) for a removed node instead of
returning a bad DataValue. The two subscription-survival assertions now expect
the throw via Should.ThrowAsync. Behavior under test (removed node -> unknown)
is unchanged; only the delivery mechanism differs.
Suite 4F -> 4/4 green. Integration-sweep follow-up #5.
All five suppressed advisories are now resolved at baseline/resolved versions,
so every NuGetAuditSuppress is removed repo-wide:
- System.Security.Cryptography.Xml (GHSA-37gx-xxp4-5rgx / GHSA-w3x6-4m5h-cxqf)
-> fixed by the .NET 10 baseline (10.0.6)
- OPCFoundation Opc.Ua.Core (GHSA-h958-fxgg-g7w3) -> fixed at resolved 1.5.378.106
Two were still live and are now patched via direct security pins:
- OpenTelemetry.Api 1.9.0 -> 1.15.3 (GHSA-g94r-2vxg-569j) pinned in Cluster;
Runtime/ControlPlane/AdminUI + tests inherit via project reference
- Tmds.DBus.Protocol 0.20.0 -> 0.21.3 (GHSA-xrw6-gwf8-vvr9) pinned in Client.UI
Also correct the Historian sidecar runtime comments (x86 -> x64, matching the
csproj PlatformTarget). Solution audit: 0 vulnerable packages; full build clean.
Opc.Ua.Server was pinned 1.5.374.126 while Client/Configuration were 1.5.378.106, so the
published Host unified Opc.Ua.Core to 1.5.378 (which dropped Opc.Ua.INodeIdFactory that Server
1.5.374 referenced). Every driver-role node (and the fused site nodes) failed to start the OPC
UA server with TypeLoadException, leaving the OPC data plane dead and the site UIs at 503.
Align all OPC UA packages to 1.5.378.106 (bump Server; drop the Opc.Ua.Configuration/Client
VersionOverrides in OpcUaServer + its integration tests) and port the server host to the
1.5.378 async API:
- ApplicationInstance requires an ITelemetryContext ctor (DefaultTelemetry.Create)
- Start/Stop/LoadApplicationConfiguration/Validate -> async; CheckApplicationInstanceCertificate
-> CheckApplicationInstanceCertificatesAsync
- ImpersonateEventHandler is now (ISession, ImpersonateEventArgs)
- UserNameIdentityToken.DecryptedPassword is now byte[] (UTF-8 decode)
- tests ported (byte[] passwords; async discovery/session/read client API)
Verified: full solution builds, OpcUaServer unit tests 52/52, and in docker-dev all six OPC
endpoints (4840-4845) listen and the site UIs return 302 (were 503). End-to-end OPC behaviour
(read/write/subscribe/security under 1.5.378) still needs a functional client test.
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public
members surfaced by commentchecker — resolves 5,847 of 5,869 issues
(99.6%) across three /fixdocs passes.