Commit Graph

626 Commits

Author SHA1 Message Date
Joseph Doherty a0a49d3395 fix(driver.sql): advance LastSuccessfulRead on evidence the database answered (Driver.Sql-006) 2026-08-10 08:02:49 -04:00
Joseph Doherty 886ce1b87c fix(sql): chunk the key-value IN list at the dialect's bind ceiling (Driver.Sql-002, Driver.Sql.Dialect-002)
ISqlDialect gains MaxBindParameters — the per-command ceiling the seam was
missing while modelling everything else that differs per backend: 2098 usable
of SQL Server's 2100 (sp_executesql spends two), 1000 for Oracle's IN-list
limit (ORA-01795, tighter than its 64k bind count), 65535 for the Postgres
Bind message.

SqlGroupPlanner.AddKeyValuePlans now emits several plans for one group when
its distinct keys exceed that ceiling, instead of one statement the provider
refuses after the connection opened — which left every tag in an EAV group
publishing BadCommunicationError on every poll, permanently, and reported the
database endpoint as down. Chunks share the group key; members follow their
own key so a shared keyValue never splits. SqlPollReader is unchanged: it runs
one command per plan and slices each plan's own Members back, proven by a
fixture read at a ceiling of 1.
2026-08-10 08:02:44 -04:00
Joseph Doherty 235e06a875 fix(calc): evaluate off the mux callback thread and out from under the state lock (Driver.Calculation-005)
OnDependencyValue ran every change-triggered dependent's script INLINE, under _lock,
via TimedScriptEvaluator.RunAsync(...).GetAwaiter().GetResult() — on the Akka dispatcher
thread of Runtime's DependencyConsumerMuxAdapter, for up to RunTimeout (2 s default) per
arrival, with the state lock held for the whole run.

The callback now records the value, PREPARES the affected tags under the lock (definition
+ warm-up gate + dependency snapshot taken at trigger time) and queues them for a single
serialized evaluation pump. _lock is a short-held state lock again; a new _evalGate
serializes the pump against the timer ticks and is taken only by evaluation workers, so
no host thread can wait on a script. Lock order is always _evalGate -> _lock.

Semantics preserved: per-tag ordering (one FIFO pump), the warm-up gate BEFORE the
evaluator runs, dedup/Bad-transition/recovery publishes, and — because the dependency
snapshot is taken when the trigger fires rather than when the pump catches up — a burst
of arrivals still evaluates against the values that triggered it.
2026-08-10 08:02:44 -04:00
Joseph Doherty 2d7dffcc42 fix(mtconnect): volatile _options publication, IConvertible write guard, idempotent client dispose
Driver.MTConnect-005/-006/-007, each TDD'd red-first.

- -005: _options was the one field at the StartCoreAsync commit point published by a
  plain write and read lock-free from ReadAsync/WriteAsync/DiscoverAsync/HostName/health.
  Now Volatile.Write/Volatile.Read like _session/_binding/_announcedInstanceId, pinned by
  a source scan (MTConnectOptionsPublicationTests) that fails on any unfenced touch.
- -006: TryFormatValue guarded null and Array, but Convert.ToString renders ANY
  non-IConvertible value as its type name under a Good status. Guard is now the property
  the remark relies on; the accepted set (string/bool/numeric/DateTime) is unchanged.
- -007: MTConnectAgentClient.Dispose was a check-then-set on a non-volatile bool, so two
  racing disposals both passed and the loser cancelled an already-disposed CTS. Now an
  Interlocked.Exchange claim over an int, with the request seams reading it volatile.
2026-08-10 08:02:15 -04:00
Joseph Doherty dd1cd984cd merge: MQTT driver+transport review findings resolved (Driver.Mqtt-006/-007, Driver.Mqtt.Transport-002) 2026-08-10 08:01:34 -04:00
Joseph Doherty cd4b29a368 fix(sql-browser): close two races around the registry reaper (Driver.Sql.Browser-002)
(1) DisposeAsync disposed _gate unconditionally. SemaphoreSlim.Dispose does not
complete pending async waiters, and the in-flight call's Release() then threw
ObjectDisposedException from inside the semaphore (swallowed by the finally), so
a caller parked in WaitAsync was never released and its call never returned. The
gate is now left alive - the pattern SqlPollReader documents - so the waiter is
admitted and meets the session's own guarded ThrowIf(_disposed, this).

(2) LastUsedUtc advanced only on completion, so a slow catalog call (the AdminUI
allows 20 s) was invisible to the TTL reaper for its whole duration and a session
at the edge of its TTL could be disposed mid-call. It is now stamped on entry
too.
2026-08-10 08:01:30 -04:00
Joseph Doherty ee1f1b28e8 fix(driver.sql): a post-open query failure is not a reachability verdict (Driver.Sql-005) 2026-08-10 08:00:51 -04:00
Joseph Doherty a8cfc886a3 fix(sql-browser): rank the row-selector candidate so a date-only column is a last resort (Driver.Sql.Browser-001)
PreferredTimestampColumn nominated the first column mapping to DriverDataType
.DateTime, and that set includes date-only types (SQL Server / PostgreSQL
'date'). A table whose first date/time column is a 'date' committed
rowSelector.topByTimestamp = <date>, making the wide-row read ORDER BY <date>
DESC LIMIT 1 - which ties for every row written that day, so 'the newest row'
became storage order among the ties.

Time-bearing candidates now outrank date-only ones; a date-only column is still
stated when it is all the table has, so such a table stays bindable. Oracle's
DATE carries a time of day and is exempt - pinned by a control dialect that
differs from the SQLite one only in the Provider it reports.
2026-08-10 07:59:35 -04:00
Joseph Doherty 90f3016a3e fix(driver.sql): defer HandlePollError on the exception ReadAsync classified, not on its type (Driver.Sql-004) 2026-08-10 07:59:09 -04:00
Joseph Doherty 3f85ba985e fix(mqtt): stop disposing the primary-host gate a live reconcile still holds
Driver.Mqtt-006 (Low, concurrency). DisposeAsync disposed _gate while StopAsync
cancels the reconcile loop WITHOUT awaiting it, so a ReconcileAsync already in
flight could be inside _gate.WaitAsync, or on its way to the finally-release,
when the semaphore went away. The release then threw ObjectDisposedException
naming SemaphoreSlim, logged as a reconcile failure — telling an operator
nothing about what happened and hiding whatever the reconcile was really
failing on.

Left undisposed, matching MqttConnection's documented rule for its own lifecycle
primitives and its stated rationale: a late callback racing teardown should be a
benign no-op rather than an ObjectDisposedException naming the wrong type. Two
lifecycle types in one module disagreeing about this is what gets copied into
the third. Nothing is leaked — the gate holds no timer and no registration — and
ClaimAsync still re-checks _disposed under it, so no claim can be created after
dispose either way.

Test is deterministic rather than timing-dependent: the gate is taken before the
connect starts, so a MiniBroker in blackhole mode (TCP accepted, CONNECT never
answered) accepting the socket proves the claim is inside the gate when dispose
runs. RED: log.Captured contained "ObjectDisposedException".
2026-08-10 07:58:38 -04:00
Joseph Doherty 2298485bda fix(mqtt): a reconnect that re-establishes nothing tears the session down
Driver.Mqtt-007 (Low, error handling). OnReconnectedAsync throws when a
re-subscribe is granted zero filters — MqttConnection's contract is that a
throwing Reconnected subscriber tears the fresh session down and retries under
backoff, because a connected-but-deaf driver is the one outcome this path must
never serve. But when the live subscribed topics resolved to zero filters in the
first place it logged a warning and returned, reaching the same "nothing was
re-established" state by a different route and giving it the opposite answer.

Throw there too, and say so in the remarks so the type states ONE rule. It costs
no other tag — every live topic is in the set that resolved to nothing, so there
is nothing left flowing to protect, which is the whole reason the partial-
rejection case is exempt — and it is not permanent: the retry runs against
whatever Register has published by then.

Test reaches the state the only way production can: Register prunes
_subscribedTopics of the topics its new table no longer carries, but a SUBSCRIBE
already in flight records its own topic AFTER that prune ran, so a deploy landing
inside the round-trip leaves a live topic no authored tag resolves to. Paired
with the control that a reconnect with no live subscriptions at all stays a
no-op — throwing there would tear down the session of every driver whose tags
have not been subscribed yet.
2026-08-10 07:58:29 -04:00
Joseph Doherty 5d4dd17d7f fix(mqtt-transport): warn when a configured password is dropped for want of a username
Driver.Mqtt.Transport-002 (Low, correctness). Credentials were attached only
when Username was non-empty, so a config carrying a Password and no Username
connected anonymously with the secret silently discarded — the deployment reads
as authenticated and is not, which is the direction an operator cannot see from
the config.

Warned rather than sent. MQTT 3.1.1 may not carry a password without a
username, so the password-only CONNECT is not available on every protocol
version this factory serves, and synthesizing one under V500 only would change
the wire behaviour of deployments that connect happily today. The configured
values stay authoritative; the drop just stops being silent. The secret is
never formatted into the message.

Tests: the warning fires and does NOT contain the password, plus the falsifying
control that an ordinary anonymous config (neither credential set) stays silent
— without it the fix could warn on every connect and still pass.
2026-08-10 07:58:19 -04:00
Joseph Doherty 74594e6083 fix(sql-dialect): enforce Postgres/Oracle identifier ceilings in UTF-8 bytes (Driver.Sql.Dialect-001)
NAMEDATALEN-1 (63) and Oracle 12.2's 128 are byte limits in the database
encoding, not character counts, so a 32-character Cyrillic name passed
ident.Length and was then silently truncated (Postgres) or rejected by the
server (Oracle). Both dialects now measure Encoding.UTF8.GetByteCount and say
'bytes' in the rejection. SqlServerDialect deliberately keeps ident.Length —
sysname is nvarchar(128), a real character limit — pinned by a control test.
2026-08-10 07:58:04 -04:00
Joseph Doherty 073930e023 fix(sql): withhold the JSON parser's message from the probe's red result (Driver.Sql-009)
SqlDriverProbe surfaced 'Config JSON is invalid: ' + ex.Message, where
SqlDriverBrowser.ParseDocument deliberately withholds the identical message
because the malformed text may itself carry a connection string. The two read
the same blob shape - the AdminUI Sql picker composes a document with a
top-level connectionString literal - so a malformed paste reaches both. The
probe now reports the failure class only, matching the browser.
2026-08-10 07:56:58 -04:00
Joseph Doherty 1c67d019e5 docs(mtconnect): describe the fixed browse-commit coercion type (#560)
The comments and docs that described Driver.MTConnect-003 as live at HEAD would
have been wrong the moment 64be41d8 landed:

- code-reviews/Driver.MTConnect/findings.md — Driver.MTConnect-003 Resolved,
  with the fixing commit; module open-finding count 5 -> 4.
- code-reviews/Driver.MTConnect.Contracts/findings.md — the one clause inside
  Contracts-001's prose that asserted 003 was Open.
- docs/drivers/MTConnect.md — the coercion-precedence warning now states that a
  browse-committed tag resolves at step 1 CARRYING the step-3 answer, and that
  step 3 remains the rescue for a hand-authored / CSV / API blob with no type.
- MTConnectDriver.BuildBinding, MTConnectDataTypeInference and
  MTConnectDriverOptions.RawTags remarks — same correction, each keeping a short
  historical note of what the defect was so a reader meeting the old blobs still
  understands them.

Comment-only in src; the driver suite (538) and AdminUI suite (1474) re-run green.
2026-08-10 07:36:45 -04:00
Joseph Doherty d68009106b merge: Mqtt runtime + Transport code review — deaf-reconnect subscription reset (High), teardown-before-reinit session leak (High), timeout normalization, dead CA-pin warning; 12 findings 2026-08-10 07:02:15 -04:00
Joseph Doherty 147b624437 merge: Calculation + OpcUaClient.Session code review — warm-up gate before evaluation (spurious script-throw warnings), evaluator logger wiring, probe JSON-leniency parity; 7 findings 2026-08-10 07:00:33 -04:00
Joseph Doherty c58e833aee merge: Mqtt Contracts+Browser code review — wildcard PUBLISH refusal (whole-driver outage path), Sparkplug segment shape rules, rebirth-scope wildcard gate; 12 findings 2026-08-10 07:00:22 -04:00
Joseph Doherty 978eeda753 merge: MTConnect family code review — sample-pump hot-loop backoff, probe deviceName path, stale-premise docs; 9 findings (High browse-commit String coercion recorded cross-module) 2026-08-10 07:00:09 -04:00
Joseph Doherty 9ccc0d5678 merge: Sql family code review — default-schema fallback (whole-driver outage path), rowSelector doc fix, dead SqlClient ref; 18 findings recorded across 4 modules 2026-08-10 06:59:53 -04:00
Joseph Doherty 74b852716c fix(mqtt-transport): warn when the untrusted-cert hatch voids a pinned CA
Driver.Mqtt.Transport-001 (Medium, Security). allowUntrustedServerCertificate
and caCertificatePath are independent settings, and when both are set the hatch
wins SILENTLY: ConfigureTls installs the accept-everything validator and
returns before the pin is consulted. The combination is not exotic — the hatch
is what an operator turns on while standing a broker up and the pin is what
they add afterwards — and the failure is silent in the direction that matters:
the config reads as pinned, and nothing validates anything.

Both knobs are explicit, so the flag stays authoritative (overriding it would
break a deployment that genuinely wants the hatch, and refusing to build would
fault a driver over a config we have been accepting). Saying so once, at the
seam that resolves the conflict, is the proportionate answer. No behaviour
change; the factory's optional ILogger already exists for this class of
deferred diagnostic and never formats credentials.
2026-08-10 06:59:34 -04:00
Joseph Doherty b4a03b4baa fix(calculation): probe JSON options stricter than the real spawn/reinit path (review)
CalculationDriverProbe.Opts (Test-Connect) omitted AllowTrailingCommas and
ReadCommentHandling that CalculationDriverFactoryExtensions.JsonOptions
(spawn) and CalculationDriver.ReinitJsonOptions (in-place ApplyDelta) both
set, so a config blob the real deploy path tolerates could fail Test-Connect
as "invalid JSON" even though deploying it would succeed. Aligned the three
option sets. Also adds CalculationDriverProbeTests.cs, which previously did
not exist at all for this driver type's Test-Connect surface.

Part of code-reviews/Driver.Calculation/findings.md (-003, -004).
2026-08-10 06:59:29 -04:00
Joseph Doherty a836e0d983 fix(calculation): dead logger cast + warm-up evaluated before change-gate (review)
Code review of Driver.Calculation found two real defects, both TDD-fixed:

- CalculationDriver's ctor tried to reuse its ILogger<CalculationDriver> as the
  evaluator's ILogger<CalculationEvaluator> via an `is` check that can never
  succeed (unrelated closed generics), so CalculationEvaluator always ran with
  a NullLogger regardless of what the driver was constructed with. Fixed by
  having CalculationEvaluator accept the non-generic ILogger instead.

- EvaluateTag called the evaluator BEFORE checking whether every declared
  dependency had arrived, so a multi-dependency change-triggered calc tag
  evaluated its script against a partial snapshot on every warm-up tick.
  VirtualTagContext.GetTag returns a Bad snapshot (.Value == null) for a
  missing dep, so the idiomatic `(double)ctx.GetTag("x").Value` cast throws
  NullReferenceException — caught and logged as a spurious "script threw"
  script-log Warning on ordinary deploy/restart warm-up, for the standard
  multi-input calc-tag shape. Fixed by gating evaluation itself on
  "all deps arrived", not just the publish.

See code-reviews/Driver.Calculation/findings.md for full detail (5 findings:
001-004 Resolved, 005 Open/cross-module).
2026-08-10 06:59:23 -04:00
Joseph Doherty 2b4b3fcbbf fix(mqtt): session-rebind subscriptions, re-init teardown, timeout clamp
Findings from the per-module review of Driver.Mqtt at b990adae
(code-reviews/Driver.Mqtt/findings.md records all ten; these are the fixed
ones).

Driver.Mqtt-001 (High) — MqttSubscriptionManager._subscribedTopics is a claim
about the broker session it established filters on, and AttachTo never cleared
it, but the manager OUTLIVES a session rebuild (AdoptOptions keeps it whenever
the ingest identity is unchanged). After a driver-host reconnect
(ShutdownAsync + InitializeAsync, the #527 watchdog's retry) or a
ReinitializeAsync that only changed the endpoint/credentials, the host's
re-subscribe resolved an empty pending set, sent no SUBSCRIBE at all, and left
the driver Connected/Healthy on a session carrying ZERO subscriptions — no
error, no Bad status, values frozen until the new session happened to drop.
AttachTo now forgets them, mirroring SparkplugIngestor.AttachTo's reset.

Driver.Mqtt-002 (High) — InitializeCoreAsync published _connection and
_primaryHost over whatever the driver already held, so a second initialize
stranded a connected, self-supervising broker session (plus a second Sparkplug
primary-host claim) that no later dispose could reach. Reachable without any
teardown of ours via DriverInstanceActor.AdoptConfigDuringInit. Now tears down
first, under the gate both callers already hold.

Driver.Mqtt-003 (Medium) — connectTimeoutSeconds is [Range]-annotated but
unvalidated on the runtime path; 0 makes every deadline fire immediately and a
negative value throws ArgumentOutOfRangeException out of ShutdownAsync and
DisposeAsync. Normalized once, at the seam every options instance passes.

Also: ShutdownAsync keeps the live last-message instant (-004), three usings
left behind by #512 removed (-005), stale remarks corrected (-009, -010), and
docs/drivers/Mqtt.md now distinguishes the two kinds of reconnect.

Tests 708 -> 713. All three regression tests were confirmed to fail against
the un-fixed code, with two controls that pass in either state.
2026-08-10 06:59:18 -04:00
Joseph Doherty 69ad376f0d review(Driver.Sql): findings + fix the missing default-schema fallback, the rowSelector doc, and a dead package ref
Driver.Sql-001 (Medium): SqlCatalogLoader.ReadDefaultSchemaAsync documented a
fallback to the sole visible schema when the server reports no default schema and
did not implement it, so a login with no DEFAULT_SCHEMA (or a Postgres search_path
that resolves to nothing) rejected EVERY unqualified authored table at the catalog
gate — a whole-driver BadNodeIdUnknown outage against a healthy database. Fixed;
SqlCatalogDefaultSchemaTests written red first, with a control proving the
ambiguous multi-schema case still refuses to guess.

Driver.Sql-003 (Medium): docs/drivers/Sql.md spelled the WideRow row selector at
the top level, but the parser reads those keys only inside a nested rowSelector —
a tag authored from the doc is refused and reads BadNodeIdUnknown (the #552 class,
via the documentation). Also removed the documented-but-nonexistent pollIntervalMs
per-tag field.

Driver.Sql-007 (Low): dropped the unused Microsoft.Data.SqlClient PackageReference
left behind by the .Dialect extraction (#526).

Open: 002 (no IN-list chunking vs the 2100/1000 provider bind caps), 004, 005, 006,
008, 009, 010.
2026-08-10 06:58:08 -04:00
Joseph Doherty 55b12dc217 fix(historian-gateway): map alarm severity numerically; dispose provisioner's gRPC channel
Driver.Historian.Gateway-001 (High): AlarmEventMapper wrote the alarm's
Severity wire property as the .NET enum name (e.g. "High"), but
EventMapper's read side int.TryParse()s that same property and silently
falls back to the minimum severity on any unparseable value - so every
alarm event's severity round-tripped through this module's own mappers
collapsed to 1 (Low), contradicting AlarmHistorianEvent.Severity's own
documented contract ("mapped to Historian's numeric priority"). Now
mapped through a numeric priority mirroring the existing
NativeAlarmProjector.MapSeverity convention (200/500/700/900).

Driver.Historian.Gateway-002 (Low): GatewayTagProvisioner never disposed
its IHistorianGatewayClient, unlike its GatewayHistorianDataSource /
GatewayAlarmHistorianWriter siblings. Now implements IAsyncDisposable so
the DI-owned singleton's gRPC channel closes gracefully at shutdown.

Both TDD: new/corrected tests confirmed RED against the pre-fix code.
2026-08-10 06:53:41 -04:00
Joseph Doherty 3118213772 fix(mqtt-browser): reject a wildcard rebirth scope before any NCMD leaves
SparkplugRebirthScope (the AdminUI's typed input) rejects '+'/'#' and its own
remarks say it is 'advisory, not the gate' because MqttBrowseSession
.ResolveRebirthTargets 'refuses an unusable one BEFORE any message leaves'. That
claim was false: the bare {group}/{edgeNode} branch — honoured on purpose, since a
node that has not birthed is the prime rebirth target — gated on IsUsableLabel,
which checks length and control characters only. A scope of 'Plant1/#' therefore
published spBv1.0/Plant1/NCMD/# , a PUBLISH the MQTT spec forbids and a conformant
broker answers by closing the browse connection; '+' would have fanned one
operator click across every matching edge node.

The check is a separate IsUsableRebirthSegment rather than a tightening of
IsUsableLabel: that helper also judges Sparkplug METRIC names, which are arbitrary
publisher-chosen UTF-8 and never part of a topic, so tightening it there would drop
legitimate metrics from the tree. Cases 1 and 2 cannot reach this shape — their ids
come off SparkplugTopic.TryParse, which already rejects both characters.

Driver.Mqtt.Tests 724 (was 708).
2026-08-10 06:51:59 -04:00
Joseph Doherty 6c63bf8fab fix(mtconnect): back off a /sample re-baseline that resolved nothing; scope Test Connect to the configured device
Driver.MTConnect-001 (Medium): StreamVerdict.Reopen reset the reconnect ladder
unconditionally. The InvalidDataException catch that routes an Agent OUT_OF_RANGE
to a /current re-baseline also catches an unparseable chunk and an over-sized
multipart part - neither of which a re-baseline can resolve - so the pump reopened
and failed with no delay at any point: two HTTP requests and one Warning per
iteration, forever. The Reopen arm now uses the same discriminator the transient
arm does (did THIS connection deliver a chunk?), so a buffer roll behind a working
stream still reopens instantly while a re-baseline that resolved nothing advances
BackoffFor.

Driver.MTConnect-002 (Medium): MTConnectDriverProbe requested {AgentUri}/probe
while MTConnectAgentClient requests {AgentUri}/{DeviceName}/probe, so a mistyped or
since-renamed deviceName showed GREEN on Test Connect and then Faulted the driver
at InitializeAsync (an unknown device path answers MTConnectError under HTTP 200).
The probe's minimal DTO now reads deviceName - the rule is 'which keys compose the
URL', not 'which keys are cheap to read'.

Driver.MTConnect-008 (Low): corrected two stale claims that a since-changed
RawBrowseCommitMapper invalidated (see Driver.MTConnect-003, which remains open and
belongs in AdminUI), and made DiscoverAsync log the options snapshot it
deliberately read once instead of the field.

Tests: 538 pass (534 base + 4 new, each red before its fix); AdminUI.Tests 1466 pass.
2026-08-10 06:51:39 -04:00
Joseph Doherty 6eace4bbba fix(mqtt-contracts): refuse unpublishable write destinations and advise on them at deploy
A wildcard writeTopic was published verbatim. MQTT-3.3.2-2 forbids a wildcard in a
PUBLISH topic and a conformant broker answers a protocol violation by closing the
connection — which for this driver is the one connection every subscription lives
on, so a single write to a mis-authored tag took the whole driver dark. The
Sparkplug side had the same hole plus a worse one: the binding tuple IS the
NCMD/DCMD topic, so a '/' in groupId/edgeNodeId/deviceId silently addressed a
different edge node than the tag names.

MqttWriteEncoder now refuses both as NoWriteDestination (-> BadNotWritable); the
read path is untouched. metricName is exempt on purpose — it rides in the payload
and Sparkplug's own canonical names use '/'.

MqttTagDefinitionFactory.Inspect gained the matching ADVISORIES (never rejections
— the mappers accept these blobs, and the gate must never be stricter than the
runtime). Both rules were already hard errors in the AdminUI's typed editor, but
that is one authoring path of several: the raw-JSON textarea, CSV import and the
API all reach the deploy gate directly, so the authoring surface was stricter than
the gate — the drift class the #549-#559 arc exists to close.

Shared shape rules single-sourced in the new internal MqttAddressRules.

Driver.Mqtt.Tests 724 (was 708); AdminUI.Tests 1466; ControlPlane.Tests 261.
2026-08-10 06:51:39 -04:00
Joseph Doherty 621a9e5dc2 fix(mqtt): runtime mappers no longer refuse leading-whitespace TagConfig — JsonDocument.Parse + ValueKind is the single framing authority (#559)
FromTagConfig and FromSparkplugTagConfig each carried a framing pre-check
(`tagConfig[0] != '{'`) evaluated on the UNTRIMMED string, so a TagConfig blob
with leading whitespace was refused by MQTT alone and the tag read
BadNodeIdUnknown forever — while the other six structural-parse drivers
(Modbus, S7, AbCip, AbLegacy, TwinCAT, FOCAS) hand the identical blob to
JsonDocument.Parse, which skips leading whitespace per the JSON spec.

The clause is dropped (the blank guard stays). JsonDocument.Parse plus the
root-ValueKind check now decide framing, exactly as for the six siblings: an
array/number/string root fails ValueKind, non-JSON is a JsonException. The gate
was a validator, not a discriminator — no caller (MqttSubscriptionManager,
SparkplugIngestor, MqttTagConfigModel, Inspect) used the first byte to pick a
format — so verdicts are identical for every input except whitespace-padded
JSON objects, which now get their content's verdict.

Inspect needs no logic change (it has trimmed since #556 and hands the RAW
reference to the mappers), but its comments claimed the padded-blob refusal was
production-reachable; rewritten. That shape was also MQTT's only vehicle for the
catch-all backstop, which is now unreachable-today like FOCAS's — so its test is
replaced by the same count-relation pin, and the backstop code stays as
defence-in-depth.

Tests: both mappers pinned by padded-vs-unpadded DEFINITION equality (a record,
so field-wise), padded non-object/malformed negative controls, an Inspect
verdict+inspection parity theory over the accepted AND rejected corpus with an
anti-vacuity control, and a padded MQTT corpus entry in the AdminUI
authoring/runtime parity suite.
2026-08-10 03:36:46 -04:00
Joseph Doherty be15ed160a merge: #556 + #557(Mqtt) — Inspect pre-filters trim before framing; rejection vs advisory classified structurally (backstop gates on rejections only); Mqtt union verdict kept with a mode-dependency advisory 2026-08-10 03:08:08 -04:00
Joseph Doherty f5475868f7 fix(inspect): trim before the framing check; stop advisories swallowing the backstop (#556); pin the MQTT payloadFormat mode contract (#557 item 2)
#556 item 1 — leading whitespace defeated every Inspect's pre-filter. Seven
factories (Modbus/S7/AbCip/AbLegacy/TwinCAT/FOCAS/Mqtt) tested
`reference[0] != '{'`, so a padded blob returned EMPTY and a tag the driver
refuses deployed clean. The check now trims first, matching the idiom
Sql/Calculation/MTConnect/OpcUaClient already used. The raw reference is still
what is handed to the mapper — the driver reads the stored blob, not a trimmed
copy — so the gate keeps mirroring the runtime rather than becoming lenient.
Both directions are pinned: a padded blob the mapper accepts still draws
nothing, and one that is not object-framed AFTER trimming still draws nothing
(it is not an equipment-tag TagConfig at all).

Six of the seven mappers hand the blob to a whitespace-tolerant
JsonDocument.Parse, so their verdict is unchanged by padding. MQTT is the
exception: both its readers carry the same framing gate, so a padded blob is
genuinely refused — which is why the untrimmed pre-filter was a real defect
there and not a cosmetic mismatch.

#556 item 2 — FOCAS and MQTT appended advisories unconditionally and then gated
the catch-all rejection message on `warnings.Count == 0`, so an advisory (which
fires on ACCEPTED blobs too, and says nothing about a refusal) silently
swallowed the only message naming a refusal nothing else can. The two classes
now accumulate in SEPARATE lists and the backstop gates on the rejection count
alone — structural, not string matching. MQTT's swallow was reachable in
production (a padded blob its readers refuse while every describe branch finds
the parsed document well-formed); FOCAS's backstop is currently unreachable by
audit, so its guard is protective.

#557 item 2 — decided and pinned: KEEP the union verdict. Evidence:
FromSparkplugTagConfig hard-codes PayloadFormat=Json and never consults the key;
only MqttSubscriptionManager (the Plain ingest path) decodes by it; and
MqttTagConfigModel.ToJson deliberately omits the key entirely in Sparkplug mode
(#513). So a Sparkplug driver genuinely serves the tag and rejecting it would be
stricter than the runtime. The cost — served behaviour depends on the driver's
MqttMode, which no tag row records — is paid by an ADVISORY naming the key and
the mode dependency, not by changing the verdict, so both gates keep agreeing.
The same invalid value on a blob the union REFUSES stays a rejection; the class
is decided by the accept gate, never by the key.

Falsified: reverting Modbus's trim reddens the padded-rejection theory;
neutering MQTT's backstop guard to the pre-#556 shape reddens the
advisory-plus-unnameable-rejection test; disabling the #557 advisory reddens the
contract pin; and for FOCAS, removing a describe branch alone stays green (the
backstop covers it) while additionally neutering the guard goes red.
2026-08-10 03:07:18 -04:00
Joseph Doherty 93a058287c merge: #557 (OpcUaClient half) — editor reads the legacy PascalCase NodeId at the reader's presence-shadows precedence and drops it on save; #554 stale exemption removed with the anti-vacuity guard as control 2026-08-10 03:02:12 -04:00
Joseph Doherty be5899bc7d fix(adminui): OpcUaClient editor reads the legacy PascalCase NodeId at the reader's precedence (#557 item 1)
`OpcUaClientTagDefinitionFactory.TryReadNodeId` still honours a legacy PascalCase
`NodeId` when the v3 camelCase `nodeId` is wholly absent, but
`OpcUaClientTagConfigModel` read only `nodeId` — so a legacy blob was SERVED by
the driver yet opened with an empty reference field and could not be saved
untouched. Authoring stricter than the reader, which #554 names as never
legitimate: the editor was blocking config the runtime honours.

Fixed with the #550 pattern (read both spellings, normalise on save), NOT by
retiring the spelling from the reader — that would break every legacy blob the
driver currently serves at the next deploy, a data-plane regression traded for
an editor asymmetry.

The precedence is PRESENCE-shadows, not first-non-blank. The reader's
`TryGetProperty("nodeId", out n) || TryGetProperty("NodeId", out n)`
short-circuits on the mere PRESENCE of the camelCase key and then checks
string-and-non-blank ONCE, so a blank / non-string / JSON-null `nodeId` beside a
valid legacy `NodeId` is a REJECTED blob, not a fallback. Copying MTConnect's
`FirstNonBlank` walk here would have made authoring WEAKER than the reader —
the same defect in mirror image.

- `NodeIdKeys` drives both halves, so the read and the drop cannot drift.
- `ToJson` writes `nodeId` and drops `NodeId`; the TagModal history-merge keys
  (`isHistorized` / `historianTagname`) are disjoint and untouched.
- `Validate`'s required-reference fast path is now precedence-aware by
  construction, so it agrees with the #554 parse consult across the whole
  rejection surface.
- The `TagConfigNonEnumParityTests` exemption for OpcUaClient is REMOVED — its
  anti-vacuity guard `Every_deliberately_stricter_entry_is_still_exactly_that`
  went red on the fix, which is this change's falsification control. The legacy
  shapes moved into the corpus, where both fleet theories now cover them.

Tests: a nine-row precedence theory driving the authoring verdict against the
READER's verdict per shape, on the original blob AND on the `ToJson()` output;
no-retype (legacy loads showing its reference, saves canonical, same node id
before and after); no-drift (output never carries `NodeId`). Each half was
reverted in isolation to confirm it reddens tests of its own: read-only-revert
=> 6 red incl. the fleet parity theory; drop-only-revert => 4 red.

Suites: AdminUI.Tests 1459/1459, ControlPlane.Tests 261/261,
Driver.OpcUaClient.Tests 143/143, Driver.OpcUaClient.Browser.Tests 10/10.
2026-08-10 03:01:41 -04:00
Joseph Doherty 17130d9c82 test(parity): consolidate the browse-commit guard onto one list; key browsers off DriverTypeNames (#558)
Two guards enumerated the same RawBrowseCommitMapper.BuildTagConfig seam against
two hand-authored lists, which can only drift. The older one's list was also
misnamed: DriverDispatchMapParityTests.NonBrowsableDriverTypes really meant
"types that produce the generic key" — AbLegacy is genuinely non-browsable yet
correctly absent from it, because it has a typed branch.

Retire the older fact. RawBrowseCommitMapperParityTests.GenericKeyExemptions is
now the single hand-authored list for this seam: named for what it holds, one
written reason per entry, and checked against a DI-derived browsable set rather
than a second list. The one assertion the retired fact made that nothing here
covered — set EQUALITY, i.e. an exemption must still DESCRIBE the mapper — moves
across as Every_generic_key_exemption_still_commits_to_the_generic_key. Without
it, a driver that gained a typed branch would keep a silently inert exemption.

Item 2: OpcUaClientDriverBrowser and GalaxyDriverBrowser returned string
literals ("OpcUaClient", "GalaxyMxGateway") where Sql/Mqtt use DriverTypeNames.
The values matched, and nothing guarded that. Repoint both at the constants —
DriverTypeNames.Galaxy carries the identical value — and add
Every_registered_browser_is_keyed_by_a_declared_driver_type_name over the same
AddAdminUI() read-back. Compared ORDINALLY: BrowserSessionService indexes on the
exact persisted string, and case-only drift (TwinCat/TwinCAT) is what
DriverTypeNames exists to end. Browser projects are out of reach of
DriverTypeNamesGuardTests, which pins the driver FACTORIES' names.

Falsified, four ways, each red naming the offender and green on revert:
  - #555 re-run: disabling the Sql branch reddens the two enumeration facts
    ("...no dedicated BuildTagConfig branch...: Sql"), the same catch the
    retired fact made.
  - giving Modbus a typed branch reddens ONLY the new stale-exemption fact,
    proving it is not redundant with the four that were already there.
  - SqlDriverBrowser.DriverType => "SQL" and Galaxy => "GalaxyMXGateway" each
    redden the new browser-key guard by name — case-only typos, which an
    OrdinalIgnoreCase compare would have waved through.
2026-08-10 02:56:05 -04:00
Joseph Doherty 7498d39e5b fix(sql): browse-commit states a topByTimestamp row selector (#552)
`RawBrowseCommitMapper.BuildSqlTagConfig` emitted a WideRow blob carrying only
table + columnName. A wide-row tag must also say WHICH row it reads, so both
`SqlEquipmentTagParser` (the runtime authority) and `SqlTagConfigModel.Validate`
(the authoring gate) refused it — a browse-committed Sql tag was never readable,
first silently as BadNodeIdUnknown and, since #551 put the gate on the import,
loudly at commit.

`SqlBrowseSession` now states a fourth address field: the table's preferred
date/time-typed column, computed from the columns its attributes call ALREADY
read (no extra catalog round-trip). Candidacy is decided by
`ISqlDialect.MapColumnType` reporting `DriverDataType.DateTime` — never by column
name, which would order a wide-row read by a string column that merely looks like
a timestamp. Multiple candidates tie-break on FIRST IN CATALOG ORDER (every
dialect's column SQL orders by ordinal position), so the pick is stable across
calls and servers; it is a visible, editable default the typed editor round-trips.

No candidate (a table with no date/time column) is an operator-actionable refusal,
not an invented selector: the only remaining selector is a whereColumn/whereValue
pair whose value is data, not schema, so `DescribeUncommittableLeaf` refuses that
leaf by name, names the table, and points at the tag editor.

The session and the mapper now agree via `SqlBrowseAddressFields` constants rather
than two independently spelled string literals — a disagreement there is silent,
and is exactly the shape this defect had.

`RawTagConfigGateTests`' Sql leg flips from "records the gap" to "browse-commit
output passes the gate", with the no-candidate case pinned as its own test.
2026-08-10 01:20:12 -04:00
Joseph Doherty 333ea48805 merge: #551 — TagConfig gate residuals: accept-gate-first Inspects (7 factories), service-enforced authoring validation (create/update/import), S7 absent-dataType + AbCip members + Modbus stringByteOrder, strict-runtime doc sweep 2026-08-10 00:20:33 -04:00
Joseph Doherty 05b424788f fix(tagconfig): close the four #551 residuals — accept-gate-first Inspect, three authoring rules, CSV/service gate, doc sweep
Gitea #551.

1. CSV import ran no driver-typed config gate. Its typed columns were always
   strictly parsed, but the free-form TagConfigJson column reached the database
   unread, so a CSV could author a tag the driver rejects — one that deploys
   green and reads BadNodeIdUnknown forever. RawTagCsvMapper.Parse now names the
   offending row in the staged review grid, and RawTreeService enforces the same
   gate on CreateTag/UpdateTag/ImportTags: a form cannot be the guarantee (the
   API and any future caller reach none of them, and this repo has no bUnit).
   A rejected import row is an ERROR — the batch inserts nothing and the row is
   named — never a skip.

   Note the brief's premise that manual entry rides ImportTagsAsync is wrong:
   RawManualTagEntryModal commits row-by-row via CreateTagAsync, which is why
   the gate had to land on all three write paths.

2/3. The seven pre-#549 Inspect methods ran a hand-list of DescribeInvalidEnum
   checks, so every rejection cause not on the list was invisible. They are now
   ACCEPT-GATE-FIRST (the MTConnect/Sql/OpcUaClient/Calculation shape): ask the
   driver's own reader for the verdict, then explain the refusal, with a
   catch-all so "the parse rejects but Inspect said nothing" is unreachable.
   That closes S7's absent dataType, AbCip members[], Modbus stringByteOrder and
   the type-dependent guards, plus causes the issue did not name (absent
   region/address/tagPath/symbolPath/topic, TwinCAT Structure, MQTT's Sparkplug
   tuple). FOCAS and MQTT keep advisories about ACCEPTED blobs, so they
   diagnose rather than return empty.

   Authoring half: ModbusTagConfigModel gains stringByteOrder;
   AbCipTagConfigModel asks the new AbCipTagDefinitionFactory.DescribeInvalidMember;
   S7TagConfigModel captures whether the SOURCE blob declared dataType and asks
   S7TagDefinitionFactory.DataTypeKey/DeclaresDataType. One authority per rule.

4. Doc sweep: the six factory Inspect summaries, EquipmentTagConfigInspector's
   class remarks and AdminOperationsActor's comment all claimed invalid enums are
   "silently defaulted by the lenient runtime" — false since R2-11 Phase C made
   the runtime reads strict. They describe rejections now.
2026-08-10 00:08:06 -04:00
Joseph Doherty 8971861b7c fix(adminui): MTConnect editor must read driverDataType at the runtime's precedence and drop the alias on save (#550)
MTConnectTagDefinitionFactory.TryFromTagConfig resolves the coercion type as
FirstNonBlank(blob.DriverDataType, blob.DataType) — driverDataType OUT-RANKS
dataType — while MTConnectTagConfigModel read and wrote dataType alone. That
broke in both directions at once:

  * a blob carrying "driverDataType": "Strng" was accepted at authoring while
    the runtime rejected the tag (the residual slice of #549), and
  * a VALID driverDataType silently overrode whatever type the editor displayed
    and saved, so the editor showed a lie and a save RETYPED the tag.

Both halves land together, mirroring the existing IdKeys pattern:

  * FromJson reads DataTypeKeys = [driverDataType, dataType] in the runtime's
    precedence, with the runtime's own per-key semantics — absent/JSON-null and
    present-but-blank fall through, a non-string token stops the walk (the
    runtime deserialise throws JsonException on it and rejects the whole tag),
    and the raw TOKEN is captured so Validate() judges what the driver judges.
  * ToJson drops every non-canonical DataTypeKeys entry and writes dataType as
    the enum NAME, so the alias can never out-rank the key the editor writes on
    the next load.
  * Validate() now names the offending spelling rather than always saying
    "dataType".

Doing only one half silently retypes existing tags on their next save; the
falsification runs recorded in the PR confirm each half-fix reddens a distinct
test.
2026-08-09 23:44:14 -04:00
Joseph Doherty 3a70a4e6ea merge: #549 — authoring never accepts a TagConfig enum the runtime rejects (6 models, one shared authority) 2026-08-09 22:15:46 -04:00
Joseph Doherty a3c0ec037f fix(adminui): authoring must not accept a TagConfig enum the runtime rejects (#549)
MTConnectTagConfigModel read `dataType` with TagConfigJson.GetEnum, which falls
back to String on ANY unrecognised value. A misspelled name ("Strng") from a
hand-authored blob, a CSV import or the API was therefore accepted at authoring
and silently rewritten, while the driver's strict parse rejected it and the tag
died with BadNodeIdUnknown. Found by the G-7 parity tests' falsifiability
control, which had to use the digits-only shape to have a case that failed.

The rule is not restated in the AdminUI. MTConnectTagDefinitionFactory exposes
its parse as `IsAcceptedDataTypeName`, documented as the one authority the
driver, the deploy gate and the authoring model all consult; the model's
Validate() asks it about the raw value the blob carries. The old digits-only
message is NOT retained as a special case: the runtime draws no distinction
between a bare number and a typo — one predicate, one Inspect warning — so a
second message here would be a second statement of a rule this model does not
own. The raw value is captured as the JSON TOKEN, because the runtime
deserialises the key into a `string?` DTO field and an unquoted number throws
there too.

The survey found the same asymmetry at six more editors, contrary to the
assumption that those runtimes silently default: R2-11 Phase C moved every
driver's TagConfig enum read to TagConfigJson.TryReadEnumStrict, which REJECTS
the tag on a present-but-invalid string, while the editors kept loading them
with a silent fallback. Modbus (region/dataType/byteOrder), S7, AbCip, AbLegacy,
TwinCAT and FOCAS now check their enums in Validate() through the runtime's own
TagConfigJson.DescribeInvalidEnumText — added alongside a public
ClassifyEnumText that TryReadEnum now delegates to, so the JSON-token door and
the string door reach one implementation. Mqtt and Sql already carried
equivalent strict checks and are untouched.

Care taken NOT to become stricter than the runtime: a present-but-non-string
token stays accepted for those six (TryReadEnum calls it absent), as does an
absent key, each pinned by a test.

Also adds a direct ProjectReference to Core.Abstractions from the AdminUI — the
save gate now leans on a type it was consuming only transitively.
2026-08-09 22:08:42 -04:00
Joseph Doherty b4f8cb8de7 refactor(opcuaclient): move NamespaceMap to a .Session leaf so Contracts is dependency-light
G-7 wired OpcUaClientTagDefinitionFactory.Inspect into the deploy-time TagConfig
gate, which gave ControlPlane a ProjectReference to
Driver.OpcUaClient.Contracts — and with it, transitively, the whole OPC UA client
stack (5 OPCFoundation packages) into every host that loads the control plane.

NamespaceMap was the only reason Contracts carried
OPCFoundation.NetStandard.Opc.Ua.Client: its entire public surface is
ISession/NamespaceTable/NodeId-typed. It moves to a new leaf project,
ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient.Session, referenced by the runtime .Driver
and by .Browser. Contracts is left with Core.Abstractions and NOTHING else —
the same shape as Calculation.Contracts.

The namespace stays ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient, so no consumer's
`using` changed. The .Session -> .Contracts direction is deliberate: the blob
read NamespaceMap needs is OpcUaClientTagDefinitionFactory.TryReadNodeId, the
one authority it shares with the deploy gate, and that must stay in the
dependency-light half.

Why a new project rather than folding NamespaceMap into the runtime .Driver and
having .Browser reference it (the Driver.Mqtt.Browser #512-style deliberate
exception): the AdminUI project-references .Browser and NOT .Driver, so that
shape would pull the OpcUaClient driver runtime — plus Core,
Opc.Ua.Configuration and Secrets.Abstractions — into the AdminUI's build/deploy
graph. That is exactly the violation #512 spent two extractions removing from
Mqtt.Browser; re-introducing it to save one csproj is a bad trade.

Guard: ContractsIsDependencyLightTests (Driver.OpcUaClient.Tests) asserts the
Contracts manifest names no Opc.Ua* assembly, plus a counterpart asserting
.Session does. An ABSENCE assertion is sound on the manifest where a presence
one is not — the compiler elides an unused reference, but it MUST emit one the
moment Opc.Ua-typed code is added. Falsified by temporarily re-adding the
package plus an Opc.Ua.NodeId-typed member: red on Opc.Ua.Types, green again on
removal.

Evidence — `dotnet list ControlPlane package --include-transitive | grep -i opc`:
  before: OPCFoundation.NetStandard.Opc.Ua.{Client,Configuration,Core,
          Security.Certificates,Types} 1.5.378.106
  after:  none (and 0 Opc.Ua*.dll in ControlPlane's output directory)
2026-08-09 21:56:29 -04:00
Joseph Doherty 0695f682c2 merge: G-7 closed — Contracts-side TagConfig Inspect for Sql/MTConnect/Calculation/OpcUaClient wired into the deploy gate 2026-08-09 21:16:16 -04:00
Joseph Doherty 2947a2b9e2 feat(drivers): Contracts-side TagConfig Inspect for Sql, MTConnect, Calculation and OpcUaClient
Deferment-register G-7: these four were validated by the AdminUI's TagConfigValidator at
authoring but by nothing at deploy, so config arriving by CSV import or API met no gate at
all. The deploy gate dispatches to a driver's *TagDefinitionFactory.Inspect in its Contracts
assembly, and none of the four had one.

Rather than mirror the AdminUI models (a mirror of an accept/reject boundary drifts silently,
with the gate describing a shape the driver no longer reads), each Inspect is built on the
driver's own runtime parse:

- Sql wraps the existing SqlEquipmentTagParser, which already lived in Sql.Contracts. The
  P3-deferred Query model stays refused; Inspect surfaces the refusal rather than weakening it.
- MTConnect's blob reader MOVED out of MTConnectDriver (it was private, with a private DTO)
  into MTConnectTagDefinitionFactory; the driver now calls it. Behaviour unchanged.
- OpcUaClient's nodeId read MOVED off NamespaceMap into OpcUaClientTagDefinitionFactory;
  NamespaceMap now calls it. Behaviour unchanged.
- Calculation gains a Contracts assembly it never had. Only the JSON reading moved there
  (CalculationTagDefinitionFactory.TryReadTagConfig); building a CalculationTagDefinition
  still needs EquipmentScriptPaths from Commons and stays in the driver, so the split is at
  the blob boundary. The new project is deliberately reference-free — a calc blob is strings,
  a bool and an int, with no Core.Abstractions type in it.

Each Inspect runs the parse FIRST and returns empty on success, so "never stricter than the
runtime" is structural rather than a promise: a warning is only reachable for a blob the
driver would have refused and then skipped silently. Calculation additionally reports two
present-but-silently-discarded fields (a non-boolean changeTriggered reads as true; a
non-positive-integer timerIntervalMs is dropped), and deliberately does NOT warn about a
trigger-less tag or a sub-50ms timer — the editor refuses both, the runtime honours both, and
the deploy gate follows the runtime.
2026-08-09 21:14:32 -04:00
Joseph Doherty 205cc4a4a3 feat(galaxy): per-code OPC UA mapping for the MxStatusDetail vocabulary
Follow-up to 20a816db: mxaccessgw published the full MxStatusDetail enum
(gateway.md @ 75c71ad, "MxStatus Detail Vocabulary", lifted from
Interop.aaMxDataConsumer.MxStatusDetail), confirming the live-captured codes
(1007 = MX_E_NotWriteable, 1008 = MX_E_WriteAccessDenied). FromCategory now
maps the write-relevant band per code before falling back to the category
bucket: 1004 -> BadOutOfRange, 1005 -> BadTypeMismatch, 1006 -> BadNotReadable,
1007 -> BadNotWritable, 1008/1012/1013/1016/1017 -> BadUserAccessDenied,
1010/1011 (initializing, transient) -> BadOutOfService. 8000
(MX_E_AutomationObjectSpecificError) deliberately stays category-level — the
object supplies its own semantics. Codes <= 0xFF are value-ambiguous with the
OPC DA quality-byte space and keep the quality path (still Bad-family).

Four new named constants, all validated by StatusCodeParityTests against the
pinned SDK. Live refusal smoke re-run green (read-only refusal now surfaces
BadNotWritable instead of generic Bad).
2026-08-09 20:16:29 -04:00
Joseph Doherty 20a816dbf4 feat(galaxy): consume the gateway's correlated write statuses; close archreview 06/S-1
The mxaccessgw OnWriteComplete correlation is live (server b948e69, worker
53f69cd — all four unary write kinds), so every write reply's statuses[0] now
carries the real COM commit outcome. Live-gating the cutover on windev found
and fixed three defects:

- StatusCodeMap.FromMxStatus truncated the correlated failure row's MxStatus
  detail code to a byte (1007 & 0xFF = 239 -> OPC DA Good band), mapping a
  REFUSED write to Good. New invariant: a row that is not IsSuccess() never
  maps Good — details > 0xFF (and contradictory Good-band substatuses) route
  by category (SECURITY_ERROR -> BadUserAccessDenied, named const covered by
  StatusCodeParityTests; COMMUNICATION/CONFIGURATION keep their codes).

- The borrow-from-subscription-registry write optimization could never commit:
  a subscription handle is plain-advised, and MXAccess refuses both the
  no-login write through it (SECURITY_ERROR detail 1008, live-captured) and
  the supervisory advise upgrade (E_INVALIDARG) — one advise per HANDLE, not
  per attribute. Removed: writer subscribedHandleSource ctor param + borrow
  branch, GalaxyDriver wiring, SubscriptionRegistry.TryResolveItemHandle +
  its forward index and test file. The writer always AddItems its own
  supervisory-advised handle, which commits fine while the same attribute is
  subscribed (live-proven; pinned by the new write-while-subscribed smoke).

- (gateway-side, fixed there) the correlation initially covered WriteSecured
  only, while the dominant no-login path emits plain Write.

Live gate, all legs PASSED against windev: happy write Good off a confirmed
status row with galaxy.writes.unconfirmed + advise_failed both FLAT; read-only
refusal surfaces Bad-family (the #5 node-revert input Galaxy could never
produce before); WriteCompletionWaitMilliseconds=0 control -> provisional Good
+ metered unconfirmed (override removed after, restoration re-verified). New
env-gated smokes: Live_correlated_write_statuses_confirm_commit_and_surface_refusal,
Live_write_to_subscribed_tag_commits_via_own_handle (replaces the borrow
smoke), GatewayGalaxyWriteMeterLiveTests (run filtered — meters are
process-wide).
2026-08-09 20:11:55 -04:00
Joseph Doherty 8b10d32728 fix(focas): disambiguate duplicate sibling axis/spindle names in the fixed tree (#548)
A CNC can report duplicate sibling names — the wonder Makino returns two
axes both called AA — which made the Axes/ subtree untrustworthy: the
browser offered two identical folders the commit gate had to refuse, and
the poll loop's name-keyed snapshot cache let the second axis silently
overwrite the first. Spindles and servo loads had the same collision in
their own keying, plus a resolve-to-first-match on the spindle read path.

Scheme: every member of a collision set gets a 1-based occurrence-ordinal
suffix in slot order (AA_1, AA_2); unique names stay bare. Chosen over the
alternatives deliberately:

- Names, not slot numbers, stay the primary identity — the segment map is
  re-derived from the live device each session, so a name-keyed path
  follows the physical axis across config changes, where a slot-qualified
  path would silently rebind on any axis-list shift and rename every axis
  on every machine for one pathological CNC.
- The WHOLE collision set is suffixed: bare AA ceases to exist when
  ambiguous, so a tag authored against it reads BadNodeIdUnknown rather
  than one arbitrary axis's data — the #534/#540 silent-wrongness class.
- Occurrence ordinal, not absolute slot: inserting/removing an unrelated
  axis never renames an existing duplicate pair. If the collision-set
  membership itself changes, segments change on the next browse and stale
  authored segments read Bad, never another axis's data.

One pure helper (FixedTreeNames.Disambiguate, collision-proof against
genuine names by suffix escalation) feeds FocasFixedTreeCache.AxisSegments
/ SpindleSegments, and the emitter, axis snapshot keys, servo-load keys
(cnc_rdsvmeter answers in slot order, so the k-th AA load belongs to the
k-th AA axis) and the spindle read resolution all consume those — they can
no longer disagree. The nameless-spindle S{n} fallback applies before
disambiguation so a fallback name colliding with a real one is handled
like any other duplicate.

Tests are red-first on the pre-fix driver (all five driver-level tests
fail on master's code): browse emits AA_1/AA_2 and no bare AA, each
duplicate reads its own position and servo load, duplicate spindles
resolve per slot, bare AA reads Bad. The wire half runs live against
focas-mock (duplicate names survive the managed wire parse and publish as
suffixed segments); the mock's dynamic store is name-keyed so the
distinct-values half stays with the offline tests. FOCAS 327/327,
integration 11/11, FOCAS.Cli 52, AdminUI 1113, ControlPlane 231.

Closes #548.

Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
2026-08-06 21:09:05 -04:00
Joseph Doherty 97a837c147 fix(abcip): controller browse honours the authored EtherNet/IP port (#539)
The two discovery-path libplctag tags (@tags symbol-list enumerator, @udt
template reader) still passed the bare Gateway host, so a browse against a
device authored on a non-default port silently browsed whatever answers on
44818 — #534's defect surviving in its discovery half. Both sites now consume
AbCipTagCreateParams.LibplctagGateway, with the Tag construction extracted
into internal static builders so the seam is unit-assertable (the #534 tests
pinned the property's composition but nothing pinned each site's consumption,
which is exactly how these two survived).

New guard: LibplctagGatewayConsumptionGuardTests scans both AB drivers'
sources and fails on any libplctag Tag built from the bare Gateway, so a
future call site cannot reintroduce the silent 44818 redirect.

Live-gated against the fixture host: browse of ab://10.100.0.35:44818
returns the nine-tag symbol table; browse of ab://10.100.0.35:44999 (nothing
listening — the issue's exact repro) now fails ErrorTimeout where it
previously returned the 44818 fixture's table.

Closes #539.

Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
2026-08-06 20:42:40 -04:00
Joseph Doherty dd900f970a fix(hosts): a driver that never built a tag table reports NO ANSWER, not zero skips
Found on the docker-dev live gate, not in tests. Two drivers that faulted
during initialise (rtu-gate, opcua1) each rendered "0 tags" on /hosts against
two authored tags apiece, because a ledger that had never committed returned
SkippedTagReport.Empty.

A zero report is a positive claim -- "this driver skipped nothing" -- and
making it on behalf of a driver that never got as far as looking is exactly
the quiet inaccuracy #541 exists to remove. GetSkippedTags() and
SkippedTagLedger.Snapshot() now return null until the first committed build,
so the column renders the same em-dash it already used for a driver that
cannot report at all. Both are 'no answer'; neither is 'nothing skipped'.

Knock-on: a FOCAS driver whose only init threw now reports null rather than a
zero report, which is strictly more honest than the assertion the test
originally made.
2026-08-05 20:16:31 -04:00
Joseph Doherty 39db75083d feat(drivers): every driver reports the authored tags it skipped (Gitea #541)
A driver builds its RawPath -> definition table at init and tolerates a
per-tag miss: an unmappable TagConfig, an unparseable address, a
capability-matrix rejection. That tolerance is right -- one bad tag must not
take down the other few thousand. What was missing is any statement of the
fact afterwards. A skip is not an error and happens before any read, so the
driver stays Healthy, errors/5 min stays 0, Last error stays empty, and Last
read advances live off the tags that did map. On the wonder Makino in #540
that reading held while focas-z-34184 ignored 20 of its 22 tags.

New optional capability ISkippedTagReporter, backed by a shared
SkippedTagLedger so the reset/commit/cap rules are one implementation rather
than one per driver. The report -- authored count, exact skipped count, and a
capped sample of RawPath + reason -- rides DriverHealthChanged to a new Tags
column on /hosts, over the Phase 5 telemetry stream. No table: a driver-only
node has no ConfigDb to write to, the lesson from #521.

The issue named eight drivers. It is twelve -- every driver in
DriverTypeNames.All has an authored-tag skip path. Calculation (no scriptId),
MTConnect (no readable DataItem id), Galaxy (no attributeRef) and OpcUaClient
(no nodeId) were unlisted, and OpcUaClient's was the quietest of the twelve:
NamespaceMap drops such an entry with a bare `continue` and not even a log
line. SkippedTagReporterFleetTests pins the invariant reflectively over every
IDriver in src/Drivers/, so a thirteenth cannot re-introduce the silence.

Sql drops a tag at TWO points and its report is the union of both: a blob
that does not map, AND an identifier the 8.1 catalog gate rejects against the
live catalog. The second is what schema drift produces -- a renamed column, a
dropped view -- months after a deployment sealed green, and reporting only
the first would have that driver claim "0 skipped" while polling half its
tags, which is worse than reporting nothing because the column would then be
actively reassuring.

Deliberately additive to driver state, never a change of it. Latching
non-Healthy for a config problem would satisfy both halves of the #527
comms-loss conjunction -- 90 s without a successful read AND non-Healthy --
and a driver whose tags were ALL skipped has no successful reads by
construction, so it would reconnect-loop forever against a healthy device.

Three details that are load-bearing rather than incidental:

- The skip digest is part of the publish fingerprint. A skipped tag leaves
  every other fingerprint component identical to a clean driver's, so without
  it PublishHealthSnapshot's dedup swallows exactly the publish carrying the
  signal -- the trap that already bit the rediscovery and host-status
  channels. The digest covers the sample, not just the counts: a redeploy
  that fixes one tag and breaks another leaves both counts unchanged.
- The count is exact; only the sample is capped, and the tooltip says so when
  it is showing fewer than it counted. A truncated list that looked complete
  would have an operator fix twenty tags and believe the job done.
- The ledger stages and commits, so an init that throws part-way leaves the
  previous report standing. A partial snapshot would read as "we now skip
  fewer tags", the opposite of the truth.

The proto field needs no companion presence flag, unlike host_statuses: a
singular message field carries real presence in proto3, and a has_ flag would
collide with protoc's generated HasSkippedTags.

Verified red-first three ways: dropping SkippedTagDigest from the fingerprint
fails the two dedup tests, removing the seam from one driver fails the fleet
guard, and dropping the catalog-gate leg fails the Sql union test. Full
solution builds with zero new warnings against 4e22f024.
2026-08-05 19:28:46 -04:00