Commit Graph

6 Commits

Author SHA1 Message Date
Joseph Doherty
d2f3a243cd Phase 6.1 Stream A.3 — wrap all 4 HistoryRead dispatch paths through CapabilityInvoker
Per Stream A.3 coverage goal, every IHistoryProvider method on the server
dispatch surface routes through the invoker with DriverCapability.HistoryRead:
- HistoryReadRaw  (line 487)
- HistoryReadProcessed  (line 551)
- HistoryReadAtTime  (line 608)
- HistoryReadEvents  (line 665)

Each gets timeout + per-(driver, host) circuit breaker + the default Tier
retry policy (Tier A default: 2 retries at 30s timeout). Inner driver
GetAwaiter().GetResult() pattern preserved because the OPC UA stack's
HistoryRead hook is sync-returning-void — see CustomNodeManager2.

With Read, Write, and HistoryRead wrapped, Stream A's invoker-coverage
compliance check passes for the dispatch surfaces that live in
DriverNodeManager. Subscribe / AlarmSubscribe / AlarmAcknowledge sit behind
push-based subscription plumbing (driver → OPC UA event layer) rather than
server-pull dispatch, so they're wrapped in the driver-to-server glue rather
than in DriverNodeManager — deferred to the follow-up PR that wires the
remaining capability surfaces per the final Roslyn-analyzer-enforced coverage
map.

Full solution dotnet test: 948 passing. Pre-existing Client.CLI Subscribe
flake unchanged.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 07:32:10 -04:00
Joseph Doherty
29bcaf277b Phase 6.1 Stream A.3 complete — wire CapabilityInvoker into DriverNodeManager dispatch end-to-end
Every OnReadValue / OnWriteValue now routes through the process-singleton
DriverResiliencePipelineBuilder's CapabilityInvoker. Read / Write dispatch
paths gain timeout + per-capability retry + per-(driver, host) circuit breaker
+ bulkhead without touching the individual driver implementations.

Wiring:
- OpcUaApplicationHost: new optional DriverResiliencePipelineBuilder ctor
  parameter (default null → instance-owned builder). Keeps the 3 test call
  sites that construct OpcUaApplicationHost directly unchanged.
- OtOpcUaServer: requires the builder in its ctor; constructs one
  CapabilityInvoker per driver at CreateMasterNodeManager time with default
  Tier A DriverResilienceOptions. TODO: Stream B.1 will wire real per-driver-
  type tiers via DriverTypeRegistry; Phase 6.1 follow-up will read the
  DriverInstance.ResilienceConfig JSON column for per-instance overrides.
- DriverNodeManager: takes a CapabilityInvoker in its ctor. OnReadValue wraps
  the driver's ReadAsync through ExecuteAsync(DriverCapability.Read, hostName,
  ...); OnWriteValue wraps WriteAsync through ExecuteWriteAsync(hostName,
  isIdempotent, ...) where isIdempotent comes from the new
  _writeIdempotentByFullRef map populated at Variable() registration from
  DriverAttributeInfo.WriteIdempotent.

HostName defaults to driver.DriverInstanceId for now — a single-host pipeline
per driver. Multi-host drivers (Modbus with N PLCs) will expose their own per-
call host resolution in a follow-up so failing PLCs can trip per-PLC breakers
without poisoning siblings (decision #144).

Test fixup:
- FlakeyDriverIntegrationTests.Read_SurfacesSuccess_AfterTransientFailures:
  bumped TimeoutSeconds=2 → 30. 10 retries at exponential backoff with jitter
  can exceed 2s under parallel-test-run CPU pressure; the test asserts retry
  behavior, not timeout budget, so the longer slack keeps it deterministic.

Full solution dotnet test: 948 passing. Pre-existing Client.CLI Subscribe
flake unchanged.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 07:28:28 -04:00
Joseph Doherty
52a29100b1 Phase 3 PR 38 — DriverNodeManager HistoryRead override (LMX #1 finish). Wires the OPC UA HistoryRead service through CustomNodeManager2's four protected per-kind hooks — HistoryReadRawModified / HistoryReadProcessed / HistoryReadAtTime / HistoryReadEvents — each dispatching to the driver's IHistoryProvider capability (PR 35 for ReadAtTime + ReadEvents on top of PR 19-era ReadRaw + ReadProcessed). Was the last missing piece of the end-to-end HistoryRead path: PR 10 + PR 11 shipped the Galaxy.Host IPC contracts, PR 35 surfaced them on IHistoryProvider + GalaxyProxyDriver, but no server-side handler bridged OPC UA HistoryRead service requests onto the capability interface. Now it does.
Per-kind override shape: each hook receives the pre-filtered nodesToProcess list (NodeHandles for nodes this manager claimed), iterates them, resolves handle.NodeId.Identifier to the driver-side full reference string, and dispatches to the right IHistoryProvider method. Write back into the outer results + errors slots at handle.Index (not the local loop counter — nodesToProcess is a filtered subset of nodesToRead, so indexing by the loop counter lands in the wrong slot for mixed-manager batches). WriteResult helper sets both results[i] AND errors[i]; this matters because MasterNodeManager merges them and leaving errors[i] at its default (BadHistoryOperationUnsupported) overrides a Good result with Unsupported on the wire — this was the subtle failure mode that masked a correctly-constructed HistoryData response during debugging. Failure-isolation per node: NotSupportedException from a driver that doesn't implement a particular HistoryProvider method translates to BadHistoryOperationUnsupported in that slot; generic exceptions log and surface BadInternalError; unresolvable NodeIds get BadNodeIdUnknown. The batch continues unconditionally.
Aggregate mapping: MapAggregate translates ObjectIds.AggregateFunction_Average / Minimum / Maximum / Total / Count to the driver's HistoryAggregateType enum. Null for anything else (e.g. TimeAverage, Interpolative) so the handler surfaces BadAggregateNotSupported at the batch level — per Part 13, one unsupported aggregate means the whole request fails since ReadProcessedDetails carries one aggregate list for all nodes. BuildHistoryData wraps driver DataValueSnapshots as Opc.Ua.HistoryData in an ExtensionObject; BuildHistoryEvent wraps HistoricalEvents as Opc.Ua.HistoryEvent with the canonical BaseEventType field list (EventId, SourceName, Message, Severity, Time, ReceiveTime — the order OPC UA clients that didn't customize the SelectClause expect). ToDataValue preserves null SourceTimestamp (Galaxy historian rows often carry only ServerTimestamp) — synthesizing a SourceTimestamp would lie about actual sample time.
Two address-space changes were required to make the stack dispatch reach the per-kind hooks at all: (1) historized variables get AccessLevels.HistoryRead added to their AccessLevel byte — the base's early-gate check on (variable.AccessLevel & HistoryRead != 0) was rejecting requests before our override ever ran; (2) the driver-root folder gets EventNotifiers.HistoryRead | SubscribeToEvents so HistoryReadEvents can target it (the conventional pattern for alarm-history browse against a driver-owned object). Document the 'set both bits' requirement inline since it's not obvious from the surface API.
OpcHistoryReadResult alias: Opc.Ua.HistoryReadResult (service-layer per-node result) collides with Core.Abstractions.HistoryReadResult (driver-side samples + continuation point) by type name; the alias 'using OpcHistoryReadResult = Opc.Ua.HistoryReadResult' keeps the override signatures unambiguous and the test project applies the mirror pattern for its stub driver impl.
Tests — DriverNodeManagerHistoryMappingTests (12 new Category=Unit cases): MapAggregate translates each supported aggregate NodeId via reflection-backed theory (guards against the stack renaming AggregateFunction_* constants); returns null for unsupported NodeIds (TimeAverage) and null input; BuildHistoryData wraps samples with correct DataValues + SourceTimestamp preservation; BuildHistoryEvent emits the 6-element BaseEventType field list in canonical order (regression guard for a future 'respect the client's SelectClauses' change); null SourceName / Message translate to empty-string Variants (nullable-Variant refactor trap); ToDataValue preserves StatusCode + both timestamps; ToDataValue leaves SourceTimestamp at default when the snapshot omits it. HistoryReadIntegrationTests (5 new Category=Integration): drives a real OPC UA client Session.HistoryRead against a fake HistoryDriver through the running server. Covers raw round-trip (verifies per-node DataValue ordering + values); processed with Average aggregate (captures the driver's received aggregate + interval, asserting MapAggregate routed correctly); unsupported aggregate (TimeAverage → BadAggregateNotSupported); at-time (forwards the per-timestamp list); events (BaseEventType field list shape, SelectClauses populated to satisfy the stack's filter validator). Server.Tests Unit: 55 pass / 0 fail (43 prior + 12 new mapping). Server.Tests Integration: 14 pass / 0 fail (9 prior + 5 new history). Full solution build clean, 0 errors.
lmx-followups.md #1 updated to 'DONE (PRs 35 + 38)' with two explicit deferred items: continuation-point plumbing (driver returns null today so pass-through is fine) and per-SelectClause evaluation in HistoryReadEvents (clients with custom field selections get the canonical BaseEventType layout today).

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-18 17:50:23 -04:00
Joseph Doherty
6b04a85f86 Phase 3 PR 26 — server-layer write authorization gating by role. Per the user's ACL-at-server-layer directive (saved as feedback_acl_at_server_layer.md in memory), write authorization is enforced in DriverNodeManager.OnWriteValue and never delegated to the driver or to driver-specific auth (the v1 Galaxy-provided security path is explicitly not part of v2 — drivers report SecurityClassification as discovery metadata only). New WriteAuthzPolicy static class in Server/Security/ maps SecurityClassification → required role per the table documented in docs/Configuration.md: FreeAccess = no role required (anonymous sessions can write), Operate + SecuredWrite = WriteOperate, Tune = WriteTune, VerifiedWrite + Configure = WriteConfigure, ViewOnly = deny regardless of roles. Role matching is case-insensitive and role requirements do NOT cascade — a session with WriteConfigure can write Configure attributes but needs WriteOperate separately to write Operate attributes; this is deliberate so escalation is an explicit LDAP group assignment, not a hierarchy the policy silently grants. DriverNodeManager gains a _securityByFullRef Dictionary populated during Variable() registration (parallel to the existing _variablesByFullRef) so OnWriteValue can look up the classification in O(1) on the hot path. OnWriteValue casts the session's context.UserIdentity to the new IRoleBearer interface (implemented by OtOpcUaServer.RoleBasedIdentity from PR 19) — empty Roles collection when the session is anonymous; the same WriteAuthzPolicy.IsAllowed check then either short-circuits true (FreeAccess), false (ViewOnly), or walks the roles list looking for the required one. On deny, OnWriteValue logs 'Write denied for {FullRef}: classification=X userRoles=[...]' at Information level (readable trail for operator complaints) and returns BadUserAccessDenied without touching IWritable.WriteAsync — drivers never see a request we'd have refused. IRoleBearer kept as a minimal server-side interface rather than reusing some abstraction from Core.Abstractions because the concept is OPC-UA-session-scoped and doesn't generalize (the driver side has no notion of a user session). Tests — WriteAuthzPolicyTests (17 new cases): FreeAccess allows write with empty role set + arbitrary roles; ViewOnly denies write even with every role; Operate requires WriteOperate; role match is case-insensitive; Operate denies empty role set + wrong role; SecuredWrite shares Operate's requirement; Tune requires WriteTune; Tune denies WriteOperate-only (asserts roles don't cascade — this is the test that catches a future regression where someone 'helpfully' adds a role-escalation table); Configure requires WriteConfigure; VerifiedWrite shares Configure's requirement; multi-role session allowed when any role matches; unrelated roles denied; RequiredRole theory covering all 5 classified-and-mapped rows + null for FreeAccess/ViewOnly special cases. lmx-followups.md follow-up #2 marked DONE with a back-reference to this PR and the memory note. Full Server.Tests Unit suite: 38 pass / 0 fail (17 new WriteAuthz + 14 SecurityConfiguration from PR 19 + 2 NodeBootstrap + 5 others). Server.Tests Integration (Category=Integration) 2 pass — existing PR 17 anonymous-endpoint smoke tests stay green since the read path doesn't hit OnWriteValue.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-18 13:01:01 -04:00
Joseph Doherty
46834a43bd Phase 3 PR 17 — complete OPC UA server startup end-to-end + integration test. PR 16 shipped the materialization shape (DriverNodeManager / OtOpcUaServer) without the activation glue; this PR finishes the scope so an external OPC UA client can actually connect, browse, and read. New OpcUaServerOptions DTO bound from the OpcUaServer section of appsettings.json (EndpointUrl default opc.tcp://0.0.0.0:4840/OtOpcUa, ApplicationName, ApplicationUri, PkiStoreRoot default %ProgramData%\OtOpcUa\pki, AutoAcceptUntrustedClientCertificates default true for dev — production flips via config). OpcUaApplicationHost wraps Opc.Ua.Configuration.ApplicationInstance: BuildConfiguration constructs the ApplicationConfiguration programmatically (no external XML) with SecurityConfiguration pointing at <PkiStoreRoot>/own, /issuers, /trusted, /rejected directories — stack auto-creates the cert folders on first run and generates a self-signed application certificate via CheckApplicationInstanceCertificate, ServerConfiguration.BaseAddresses set to the endpoint URL + SecurityPolicies just None + UserTokenPolicies just Anonymous with PolicyId='Anonymous' + SecurityPolicyUri=None so the client's UserTokenPolicy lookup succeeds at OpenSession, TransportQuotas.OperationTimeout=15s + MinRequestThreadCount=5 / MaxRequestThreadCount=100 / MaxQueuedRequestCount=200, CertificateValidator auto-accepts untrusted when configured. StartAsync creates the OtOpcUaServer (passes DriverHost + ILoggerFactory so one DriverNodeManager is created per registered driver in CreateMasterNodeManager from PR 16), calls ApplicationInstance.Start(server) to bind the endpoint, then walks each DriverNodeManager and drives a fresh GenericDriverNodeManager.BuildAddressSpaceAsync against it so the driver's discovery streams into the address space that's already serving clients. Per-driver discovery is isolated per decision #12: a discovery exception marks the driver's subtree faulted but the server stays up serving the other drivers' subtrees. DriverHost.GetDriver(instanceId) public accessor added alongside the existing GetHealth so OtOpcUaServer can enumerate drivers during CreateMasterNodeManager. DriverNodeManager.Driver property made public so OpcUaApplicationHost can identify which driver each node manager wraps during the discovery loop. OpcUaServerService constructor takes OpcUaApplicationHost — ExecuteAsync sequence now: bootstrap.LoadCurrentGenerationAsync → applicationHost.StartAsync → infinite Task.Delay until stop. StopAsync disposes the application host (which stops the server via OtOpcUaServer.Stop) before disposing DriverHost. Program.cs binds OpcUaServerOptions from appsettings + registers OpcUaApplicationHost + OpcUaServerOptions as singletons. Integration test (OpcUaServerIntegrationTests, Category=Integration): IAsyncLifetime spins up the server on a random non-default port (48400+random for test isolation) with a per-test-run PKI store root (%temp%/otopcua-test-<guid>) + a FakeDriver registered in DriverHost that has ITagDiscovery + IReadable implementations — DiscoverAsync registers TestFolder>Var1, ReadAsync returns 42. Client_can_connect_and_browse_driver_subtree creates an in-process OPC UA client session via CoreClientUtils.SelectEndpoint (which talks to the running server's GetEndpoints and fetches the live EndpointDescription with the actual PolicyId), browses the fake driver's root, asserts TestFolder appears in the returned references. Client_can_read_a_driver_variable_through_the_node_manager constructs the variable NodeId using the namespace index the server registered (urn:OtOpcUa:fake), calls Session.ReadValue, asserts the DataValue.Value is 42 — the whole pipeline (client → server endpoint → DriverNodeManager.OnReadValue → FakeDriver.ReadAsync → back through the node manager → response to client) round-trips correctly. Dispose tears down the session, server, driver host, and PKI store directory. Full solution: 0 errors, 165 tests pass (8 Core unit + 14 Proxy unit + 24 Configuration unit + 6 Shared unit + 91 Galaxy.Host unit + 4 Server (2 unit NodeBootstrap + 2 new integration) + 18 Admin). End-to-end outcome: PR 14's GalaxyAlarmTracker alarm events now flow through PR 15's GenericDriverNodeManager event forwarder → PR 16's ConditionSink → OPC UA AlarmConditionState.ReportEvent → out to every OPC UA client subscribed to the alarm condition. The full alarm subsystem (driver-side subscription of the Galaxy 4-attribute quartet, Core-side routing by source node id, Server-side AlarmConditionState materialization with ReportEvent dispatch) is now complete and observable through any compliant OPC UA client. LDAP / security-profile wire-up (replacing the anonymous-only endpoint with BasicSignAndEncrypt + user identity mapping to NodePermissions role) is the next layer — it reuses the same ApplicationConfiguration plumbing this PR introduces but needs a deployment-policy source (central config DB) for the cert trust decisions.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-18 08:18:37 -04:00
Joseph Doherty
f53c39a598 Phase 3 PR 16 — concrete OPC UA server scaffolding with AlarmConditionState materialization. Introduces the OPCFoundation.NetStandard.Opc.Ua.Server package (v1.5.374.126, same version the v1 stack already uses) and two new server-side classes: DriverNodeManager : CustomNodeManager2 is the concrete realization of PR 15's IAddressSpaceBuilder contract — Folder() creates FolderState nodes under an Organizes hierarchy rooted at ObjectsFolder > DriverInstanceId; Variable() creates BaseDataVariableState with DataType mapped from DriverDataType (Boolean/Int32/Float/Double/String/DateTime) + ValueRank (Scalar or OneDimension) + AccessLevel CurrentReadOrWrite; AddProperty() creates PropertyState with HasProperty reference. Read hook wires OnReadValue per variable to route to IReadable.ReadAsync; Write hook wires OnWriteValue to route to IWritable.WriteAsync and surface per-tag StatusCode. MarkAsAlarmCondition() materializes an OPC UA AlarmConditionState child of the variable, seeded from AlarmConditionInfo (SourceName, InitialSeverity → UA severity via Low=250/Medium=500/High=700/Critical=900, InitialDescription), initial state Enabled + Acknowledged + Inactive + Retain=false. Returns an IAlarmConditionSink whose OnTransition updates alarm.Severity/Time/Message and switches state per AlarmType string ('Active' → SetActiveState(true) + SetAcknowledgedState(false) + Retain=true; 'Acknowledged' → SetAcknowledgedState(true); 'Inactive' → SetActiveState(false) + Retain=false if already Acked) then calls alarm.ReportEvent to emit the OPC UA event to subscribed clients. Galaxy's GalaxyAlarmTracker (PR 14) now lands at a concrete AlarmConditionState node instead of just raising an unobserved C# event. OtOpcUaServer : StandardServer wires one DriverNodeManager per DriverHost.GetDriver during CreateMasterNodeManager — anonymous endpoint, no security profile (minimum-viable; LDAP + security-profile wire-up is the next PR). DriverHost gains public GetDriver(instanceId) so the server can enumerate drivers at startup. NestedBuilder inner class in DriverNodeManager implements IAddressSpaceBuilder by temporarily retargeting the parent's _currentFolder during each call so Folder→Variable→AddProperty land under the correct subtree — not thread-safe if discovery ran concurrently, but GenericDriverNodeManager.BuildAddressSpaceAsync is sequential per driver so this is safe by construction. NuGet audit suppress for GHSA-h958-fxgg-g7w3 (moderate-severity in OPCFoundation.NetStandard.Opc.Ua.Core 1.5.374.126; v1 stack already accepts this risk on the same package version). PR 16 is scoped as scaffolding — the actual server startup (ApplicationInstance, certificate config, endpoint binding, session management wiring into OpcUaServerService.ExecuteAsync) is deferred to a follow-up PR because it needs ApplicationConfiguration XML + optional-cert-store logic that depends on per-deployment policy decisions. The materialization shape is complete: a subsequent PR adds 100 LOC to start the server and all the already-written IAddressSpaceBuilder + alarm-condition + read/write wire-up activates end-to-end. Full solution: 0 errors, 152 unit tests pass (no new tests this PR — DriverNodeManager unit testing needs an IServerInternal mock which is heavyweight; live-endpoint integration tests land alongside the server-startup PR).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-18 08:00:36 -04:00