TimeAverage / Total on a Boolean node over the Gateway backend (AVEVA discrete tag, live
SysPulse) went to the gateway since native TimeAverage/Total became default-on (#694). AVEVA
refuses both modes at StartQuery; the gateway reports that only as Internal /
HistorianServerOperationException (the same answer as a historian storage fault), so the
node answered BadHistoryOperationUnsupported and the read counted as a backend failure.
HistoryRead-Processed now checks the node's scalar DataType before calling any backend and
answers BadAggregateNotSupported (Part 11 6.5.4: "If the Aggregate is not valid for the Node
then the StatusCode shall be Bad_AggregateNotSupported"). Nothing is sent, nothing is counted.
- Shared, every backend: HistoryAggregateDataTypes (Core.Abstractions) applies Part 13
5.4.2.3 Table 50: the numeric-only aggregates (Average, TimeAverage(2), Total(2), Min/Max,
ActualTime, Range, Delta, DeltaBounds, Interpolative, stddev/variance) on a String or
DateTime node are refused. Client-visible: the SQL backends used to answer every interval
BadAggregateInvalidInputs.
- Per backend: IHistorianDataSource.SupportsAggregateFor(aggregate, TypeCode?) (default true;
every production backend declares it, guard-tested). Gateway: false for native
TimeAverage/Total on a Boolean node. SqlServer/QuestDb: true, since they serve Boolean as
0/1 (stepped), so Boolean stays served there, as do the Gateway's raw-evaluated aggregates.
The residual case (a node declared numeric whose AVEVA tag is discrete) cannot be told apart
from a historian fault on the wire and still counts; that needs the gateway to surface
AVEVA's native error code as a deterministic status.
Tests: HistoryAggregateDataTypesTests, guard test, node-manager String/DateTime and per-type
refusals, Gateway capability matrix, DiscreteTagTimeWeightedWireTests (production Gateway
backend over an AVEVA-shaped fake: unsent, 0 health failures, positive controls). Each
mutation (no check, no shared rule, no backend hint, Gateway hint true, shared rule always
true, SQL inheriting the default) fails at least one. Live gate re-run read-only against
AVEVA 2023 R2 via a private HistorianGateway fa9cf31 container: SysPulse TimeAverage on the
wire = BadAggregateNotSupported, health failures unchanged; #801 gate 244 cases pass.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
#694 item 3 — historiangw#27 is fixed and now live-verified through OtOpcUa:
- ServerHistorian:Gateway:EnableNativeTimeWeighted defaults to true (false is
the kill switch for a gateway older than 9f711c1). TimeAverage / Total are
served and advertised again (12 aggregates).
- The gateway sends the interval as max(1, round(ms)) and AVEVA clips its last
interval at the request end (live). NativeAggregatePlan therefore sends a
multi-interval grid only for whole-ms intervals; a fractional interval is read
one interval per request (at most 1,000, else BadTooManyOperations), and every
one-interval request goes out rounded UP to whole ms so AVEVA answers one
clipped row. Live, a 3.0004 s clipped interval sent at its own width lost its
last 0.4 ms (Total 123 vs 123.0172).
#746 — HistorianGateway Contracts/Client 1.0.0 surface:
- Alarm history: GatewayAlarmHistorianWriter sends SendEvents batches of <=200.
A failed per-event result is re-sent alone via SendEvent (classified as
before); a refused batch (InvalidArgument etc.) goes event by event so a
poison event dead-letters alone; a systemic fault retries the rest without
sending more; Unimplemented (older gateway) falls back to SendEvent for good.
IHistorianGatewayClient.SendEventsAsync defaults to Unimplemented.
- Events reads: a capped page sends cap + 1 as ReadEventsRequest.max_events, so
the gateway completes the stream instead of the client cancelling it. An
ambiguous capped answer (foreign rows filtered out of the server's cut) or a
refused cap is re-read uncapped with the existing EventDrainBudget drain.
Tests: GatewayServerCappedEventsTests, GatewayAlarmWriterBatchTests,
GatewayNativeWholeMillisecondGridTests (gateway-faithful rounding fake), gate
tests flipped to the new default; every new test mutation-checked (each
mutation of the production change fails at least one). Live harness
AvevaGatewayHistorianFollowupsLiveGateTests (read-only) for #694/#700/#746.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
AVEVA's native TimeAverage / Total are answered with Good-status wrong values
while the gateway sends the interval in the wrong unit (historiangw#27): one
whole-span value on the earliest interval, the rest absent. Nothing on the
wire marks the answer as degraded.
Both are now refused BadAggregateNotSupported (unsent, not counted as a
backend failure, not advertised in AggregateFunctions) unless
ServerHistorian:Gateway:EnableNativeTimeWeighted is true. The default
Gateway set is the ten raw-evaluated aggregates
(GatewayHistorianDataSource.RawEvaluatedAggregates); ServedAggregates stays
the 12 the backend can serve with the flag on. The native-path tests opt in.
Also documents the ServerHistorian:Gateway sub-section (EventDrainBudget from
the previous commit) and the events drain in docs/Historian.md.
Rebased from the unpushed remed/lane-H2 branch (originally authored 2026-10-22
in session_01Ub9hGmYLQvn9XETzw7CMsT) onto current master.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV