Since #516 a DriverConfig change is stop + respawn, so DriverSpawnPlan.ToApplyDelta
was always empty and the in-place path had no producer. #663 and #664 were both
latent bugs in it. This deletes it:
- host: ApplyChildDelta, _pendingDelta, HandleApplyResult and HandleDeltaApplied
- plan: DriverSpawnPlan.ToApplyDelta
- actor: the ApplyDelta, ApplyResult and DeltaApplied messages, the Connected
reinit handler and the mid-connect AdoptConfigDuringInit
- tests: the actor tests that drove the seam
IDriver.ReinitializeAsync and each driver's implementation and unit tests stay.
Comments and docs that cited AdoptConfigDuringInit as the reason a driver must
release prior state at init now cite the IDriver contract and overlapping
retries, which still apply.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
A Connected ApplyDelta called ReinitializeAsync and kept the actor's data and
native-alarm handles, though every driver's reinit drops the driver-side
subscriptions behind them (#630). The reconcile only re-subscribes a missing
handle, so the driver went silent until a reconnect. Release both at the
driver before the reinit and re-subscribe both in a finally. Unreachable from
deploys since #516; pinned by a two-case test, each case failing against a
different wrong fix.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
- Reconcile retries of a failing alarm subscribe back off (skip 2^(n-1)-1
ticks, cap 7 => >= every 4 min at the 30 s tick) so a hanging subscribe
cannot hold the mailbox every tick; the stack is logged once per streak.
- The unreachable handler re-attach logs at Warning (it only fires on a
regression).
- OpcUaClient: a failed SubscribeAlarmsAsync detaches its notification
handler and bounds the session cleanup to 5 s under _gate;
OnEventNotification drops events from subscriptions not registered in
_alarmSubscriptions, so a stray that survives cleanup cannot deliver.
- The retry test also covers 3 failures (crosses the backoff); its tick
positive control documents its dependence on the stub's changing health.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
A data re-subscribe (every deploy's bulk SetDesiredSubscriptions push to a
kept driver) dropped the prior data subscription through the full
DetachSubscription, which also unhooked OnAlarmEvent and forgot the alarm
handle. On any deploy that did not respawn the driver, the alarm
subscription kept logging "established" while every event reached nobody
until a reconnect or respawn. The data path now uses DetachDataSubscription;
only a lost connection and PostStop detach both.
The #488 health-poll reconcile only looked at data, so an alarm subscribe
that failed on (re)connect gated the feed for the life of the connection.
ReconcileAlarmSubscription now re-attaches a missing handler and
re-subscribes a stale/missing alarm handle every tick.
OpcUaClient removes a half-built alarm subscription from its session when
SubscribeAlarmsAsync throws, so the new retries cannot accumulate.
Tests: actor-level data-resubscribe + reconcile-retry tests and an
end-to-end NativeAlarmFeedSurvivesDeployTests through DriverHostActor; all
three fail against the unfixed actor.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Both `IDriver` members had no production call site. Their only consumer was
`MemoryTracking`, deleted with the driver-tier recycle machinery in #522, and
`GetMemoryFootprint`'s doc-comment claimed "polled every 30s by Core" — which
had not been true since v3, even before #522 removed the poller.
Owner decision on #525 was (a) delete rather than (b) build the process-wide
watchdog that would consume them. The driver-side implementations are in git
history and were mostly reusable; what was always missing is the trigger, and a
member nobody calls is how the misleading doc-comment survived this long.
Removed from `IDriver`, all 12 driver implementations, and every test stub —
plus the support code that existed only to feed them, which is the part a
member-only deletion would have left behind as dead weight:
- MTConnect's three per-entry byte-weight constants, its cached
`ProbeModelDataItemCount`, and `CountDataItems` — a full device-tree walk run
on every cache fill to populate a number with no remaining reader.
- OpcUaClient's `_discoveredNodeCount` field and the discovery-pass write to it.
- MQTT's `ApproxBytesPerAuthoredTag`.
Two behavioural notes, neither a change in what the software does:
- `AbCipTemplateCache` now has no production reset path. Its only caller was
AB CIP's flush, which itself had no caller — so nothing changes except how
visible the fact is. Recorded on the type, along with the correction that its
comment's claim about a device `ReinitializeAsync` also flushing it was never
true. A UDT redefined on a live controller keeps its stale shape until the
driver instance is rebuilt.
- MTConnect's `/probe` cache is still dropped, by `InvalidateProbeModel()` on an
Agent restart. That is now `internal` rather than `private` so the tests which
used the flush purely to empty the cache drive the real path instead — they
now cover a case that actually occurs in production. Several unrelated doc
comments cited `FlushOptionalCachesAsync` as the canonical CAS example and are
repointed to it.
Tests: the ones that existed only to assert on the removed members are deleted
(3 OpcUaClient, 3 Galaxy, 2 MQTT, 1 MTConnect, 1 AbCip). Worth noting one was
vacuous — `FlushOptionalCachesAsync_resets_footprint_counter` asserted a
footprint of 0 before the flush and 0 after with no discovery in between, so it
would have passed against a flush that did nothing at all.
Full suite green except 7 failures verified identical on master before and
after (4 AbLegacy integration with the compose profile down, 3
Host.IntegrationTests), checked by name rather than assumed.
Docs corrected where they described this as live: `DriverLifecycle.md` (which
carried the #525 placeholder), `drivers/AbCip.md`, `drivers/AbLegacy.md`, and
`v2/driver-stability.md` — whose "polls this every 30 s" + per-driver
`DriverConfig` memory budget were never built as written and are now banner-ed
as design intent rather than description.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
Part 9 ConditionType.Quality was never assigned; default(StatusCode)==Good
so every native + scripted condition reported Good unconditionally — a
comms-lost device still showed a healthy, inactive, Good condition (a
wrong-VALUE bug, distinct from the null-value #473/#475). Clients (and HMIs
bucketing on IsGood) could not tell "genuinely inactive" from "lost contact".
Layer 1 — make Quality a real, plumbed field:
- AlarmConditionSnapshot gains OpcUaQuality Quality (default Good).
- MaterialiseAlarmCondition sets it (native BadWaitingForInitialData, scripted Good).
- WriteAlarmCondition projects snapshot.Quality; the delta-gate gains a Quality
member so a quality-bucket change fires a Part 9 event.
Layer 2 — drive native quality from driver connectivity (a comms-lost driver
emits no alarm transitions, and an alarm-bearing raw tag has no value variable,
so quality can't come from either existing channel):
- DriverInstanceActor Tells parent ConnectivityChanged on Connected/Reconnecting.
- DriverHostActor fans it to every native condition the driver owns as
OpcUaPublishActor.AlarmQualityUpdate (Good on connect, Bad on disconnect).
- New dedicated IOpcUaAddressSpaceSink.WriteAlarmQuality sets ONLY Quality and
fires only on a bucket change — never touches Active/Acked/Retain (an active
alarm that loses comms stays active). Not a full-snapshot re-projection, so it
can't clobber severity/message and works for a never-fired condition.
Forwarded through DeferredAddressSpaceSink (F10b trap; auto-verified by the
reflection forwarding guard). Ungated by redundancy role; no /alerts row.
Scripted conditions stay Good; worst-of-input quality deferred to #478 (Layer 3).
Tests: node-level (materialise/project/no-clobber/unknown-node no-op),
NativeAlarmProjector, DriverInstanceActor connectivity emission, DriverHostActor
fan-out, OpcUaPublishActor routing, and the wire-level guard
(Condition_event_Quality_tracks_source_connectivity_on_the_wire) — RED-verified
against a simulated pre-fix always-Good server. Existing DriverInstanceActor
parent probes ignore the new ConnectivityChanged.
Docs: docs/AlarmTracking.md §"Condition source-data Quality (#477)";
design doc docs/plans/2026-07-17-alarm-condition-quality-477-design.md.
Phase B native alarms never fired end-to-end: GalaxyDriver suppresses OnAlarmEvent until
an alarm subscription exists (_alarmSubscriptions.Count > 0), but the runtime only attached
the OnAlarmEvent handler and never called SubscribeAlarmsAsync — so the central feed stayed
gated and no transition reached the Part 9 condition / /alerts. Unit tests passed because
they inject through the IAlarmSource seam directly; the deferred live /run surfaced it.
DriverHostActor computes per-driver alarm refs (alarm-bearing tags' FullNames) and hands them
via SetDesiredSubscriptions; DriverInstanceActor calls SubscribeAlarmsAsync for IAlarmSource
drivers on Connected entry and whenever alarm refs are pushed while Connected (the deploy path),
idempotent via a cached handle reset on detach so reconnect re-subscribes.
Add AllDeadLetters probe to Native_alarm_during_reconnect_is_dropped_not_forwarded so the
test genuinely guards the Reconnecting state's Receive<NativeAlarmRaised> drop handler —
removing that handler would now cause a dead-letter and fail the assertion (false-negative
gap closed). Reword the ScriptedAlarms.md severity-mapping note: "snaps on the first
transition" → "every transition maps … overriding the authored seed from the first
transition onward", clarifying that MapSeverity runs on every event, not just the first.