Wave B of Batch 4 — the runtime binding seam for the dual namespace.
Applier (both realms, explicit realm at every sink call site):
- MaterialiseRawSubtree: Raw containers as folders + Raw tags as variables
keyed by RawPath (native-alarm tag → single Part 9 condition at the RawPath),
all in AddressSpaceRealm.Raw; historian tagname = override else RawPath.
- MaterialiseUnsReferences: each UNS reference Variable under its equipment
folder (Uns realm) + an Organizes UNS->Raw edge; inherits writable/array/
historian tagname from the backing raw tag (both NodeIds -> one tagname).
- FeedHistorizedRefs / ProvisionHistorizedTags now source RAW tags (mux ref
stays single, keyed by RawPath); ApplyPureRemove tears down raw tags + UNS
refs in place (raw-container removal falls back to rebuild).
DriverHostActor (dual-NodeId, single-source fan-out):
- _nodeIdByDriverRef value gains a realm (NodeRealmRef); rebuilt from
RawTags UNION UnsReferenceVariables so one (DriverInstanceId, RawPath) fans
to the raw NodeId AND every referencing UNS NodeId with identical
value/quality/timestamp. Write inverse map keyed by the bare id; the
ns-qualified NodeId the write hook passes is normalised (BareNodeId) so a
write to either NodeId resolves the same driver ref (-> RawPath write).
- Native raw alarm condition routing is realm-tagged (Raw); AttributeValueUpdate
+ AlarmStateUpdate carry the realm through to the sink.
Retire EquipmentNodeIds -> V3NodeIds.Uns (applier/VirtualTagHostActor) and
RawPaths.Combine (DiscoveredNodeMapper, discovered nodes are Raw now).
DeploymentArtifact.ParseComposition emits the Raw + UNS subtrees byte-parity
with the composer (reconstruct entities -> AddressSpaceComposer.Compose).
Sink surface: removed the transitional `= AddressSpaceRealm.Uns` defaults from
IOpcUaAddressSpaceSink / ISurgicalAddressSpaceSink / SdkAddressSpaceSink /
DeferredAddressSpaceSink / NullOpcUaAddressSpaceSink — every call site is now
explicit (realm reordered before the trailing optionals on EnsureVariable +
MaterialiseAlarmCondition). Node-manager convenience methods keep their
defaults (they are not the interface impl; Sdk delegates explicitly).
Tests: rewrote DriverHostActorLiveValueTests (fan-out drift, 1:N) +
DriverHostActorWriteRoutingTests (dual-NodeId raw/uns write routing) to the v3
raw+uns model; new AddressSpaceApplierRawUnsTests; migrated the EquipmentTags
provisioning/feed tests to RawTags; swept EquipmentNodeIds test callers.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
PR #423 shipped GatewayTagProvisioner + unit tests but never registered it in
DI nor passed it into the AddressSpaceApplier, so deploying historized tags used
the no-op NullHistorianProvisioning and never called the gateway's EnsureTags
(confirmed live on wonder-app-vd03: zero EnsureTags calls on a historized deploy).
Addresses HISTORIAN-GATEWAY-INTEGRATION-ISSUES.md.
Issue 1 (wire provisioner):
- Runtime: AddHistorianProvisioning extension (gated on ServerHistorian:Enabled,
mirrors AddServerHistorian) + NullHistorianProvisioning TryAdd default in
AddOtOpcUaRuntime; WithOtOpcUaRuntimeActors resolves IHistorianProvisioning and
passes it into the applier.
- Gateway driver: GatewayHistorian.CreateProvisioner factory (mirrors CreateDataSource).
- Host: Program.cs calls AddHistorianProvisioning after AddServerHistorian.
- Tests: AddHistorianProvisioningTests (config-gated registration + the
register->resolve->applier->EnsureTags chain).
Issue 2 (observability): AddressSpaceApplier logs the provisioning tally on every
successful dispatch (was gated behind Failed/Skipped > 0), including dispatched=N
so a dispatched=N/requested=0 line flags the dormant no-op. +2 tests.
Issue 3 (30s HistoryRead on unprovisioned tags): root coupling fixed by Issue 1;
documented the CallTimeout knob + coupling. Default left at 30s pending the
multi-data-point investigation the issue requests (lowering risks truncating
legitimate large reads).
Issue 4 (docs): docs/Historian.md gains a "Tag auto-provisioning (EnsureTags)"
section and CLAUDE.md a wiring/gating note (both stress ServerHistorian:Enabled).
Sibling scadaproj/CLAUDE.md carries no false claim -> unchanged.
Pre-existing Serilog observation: anchor CWD to AppContext.BaseDirectory before
AddZbSerilog so the relative file sink stops landing in C:\Windows\System32 under
the Windows-service CWD.
Builds 0-error; Runtime.Tests 355, OpcUaServer.Tests 329, Gateway.Tests 99 (+4
live-skipped) all green.