RedundancyStateActor derived the driver Primary from ClusterState.RoleLeader("driver").
Akka offers two different notions of a "first" member and they are not the same
one: role leader is the lowest-ADDRESSED Up member (host, then port), while
ClusterSingletonManager places singletons on the OLDEST — lowest up-number.
They agree on a freshly-formed cluster, which is why every existing test passed.
They diverge after any restart: the restarted node re-joins as the youngest while
keeping its address, so if it holds the lower address it becomes role leader while
the singletons stay put. The snapshot would then name a Primary that is not
hosting the work, and every Primary-gated surface follows it — inbound device
writes, native-alarm acks, the fleet-wide alerts emit, and the alarm-history
drain would all enable on the wrong node while the node actually running the
singletons stayed gated off.
BuildSnapshot now selects the oldest Up member carrying the driver role, matching
singleton placement. Leaving members are excluded: a node handing its singletons
over must not be named Primary.
NodeRedundancyState.IsRoleLeaderForDriver is renamed IsDriverPrimary, and
NodeHealthInputs.IsDriverRoleLeader likewise. Keeping the old names would have
left the wire contract asserting a derivation the code no longer uses — the same
drift that made this defect invisible.
Proven by a real two-node cluster rather than a mock. RedundancyPrimaryElectionTests
binds the first-joining node to the HIGHER port, so oldest and lowest-address name
different nodes, and includes a fixture assertion that the divergence actually
occurred — without it the real assertion could pass for the wrong reason. Positive
control: restoring the RoleLeader derivation turns exactly the two election tests
red while the fixture check stays green.
Runtime.Tests 440 passed, ControlPlane.Tests 82, Cluster.Tests 36.
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
Materialize each native alarm ONCE at the raw tag (ConditionId = RawPath, Raw
realm); wire the single condition as an SDK event notifier of each referencing
equipment's UNS folder so one ReportEvent fans to every root without
re-reporting per root (which would break Server-object dedup + Part 9 ack
correlation).
- New sink method WireAlarmNotifiers(alarmNodeId, alarmRealm,
notifierFolderNodeIds, notifierFolderRealm) on IOpcUaAddressSpaceSink,
forwarded through DeferredAddressSpaceSink + SdkAddressSpaceSink +
NullOpcUaAddressSpaceSink (the forwarding-trap guard); auto-covered by the
DeferredSinkForwardingReflectionTests realm + forwarding guards + a
hand-written forward test.
- OtOpcUaNodeManager: the normative AddNotifier(isInverse) pair + idempotent
EnsureFolderIsEventNotifier per equipment folder; tracked per condition in
_alarmNotifierWiring. Teardown symmetry: RemoveNotifier(bidirectional:true) on
RebuildAddressSpace, RemoveAlarmConditionNode, and RemoveEquipmentSubtree so no
inverse-notifier entry leaks across redeploys.
- AddressSpaceApplier.MaterialiseRawSubtree wires notifiers for each native alarm
tag, resolving its ReferencingEquipmentPaths (Area/Line/Equipment) to the
EquipmentId folder NodeIds via BuildEquipmentIdByFolderPath.
- AlarmTransitionEvent gains ReferencingEquipmentPaths (empty default); /alerts
renders the referencing-equipment list as display metadata.
- Un-skipped + rewrote the native-alarm dark tests
(DriverHostActorNativeAlarmTests x6, DriverHostActorNativeAlarmAckRoutingTests
x1) for the v3 raw-condition model; new NodeManagerMultiNotifierAlarmTests
proves multi-notifier wiring + teardown symmetry (no leaked duplicates after a
re-trip) + applier wiring test.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
Fix TESTS only (production already green) so the four in-scope test projects
compile + pass under the v3 dark address space:
- Core.Abstractions.Tests: drop AllowedNamespaceKinds/NamespaceKindCompatibility
from DriverTypeMetadata; rewrite EquipmentTagRefResolver tests to the single-func
RawPath-lookup contract (no parseRef/transient cache).
- Core.Tests: rewrite EquipmentNodeWalkerTests to EquipmentNamespaceContent(Areas,
Lines,Equipment,VirtualTags?,ScriptedAlarms?) — folders + VirtualTags +
ScriptedAlarms only; raw-tag variables dark (skipped Batch-4 placeholder). Drop
retired Equipment.DriverInstanceId.
- Runtime.Tests: rewrite golden corpus + TagConfigCorpusParityTests to the v3
RawPath/RawTagEntry round-trip (byte + TagConfigIntent parity; EquipmentTags dark).
Salvage VirtualTag + ScriptedAlarm artifact parity to the new Compose signature.
Retire the equipment-tag-materialization parity files (Array/Historize/Alias) and
the equipment-device-binding DeviceHost parity to documented skipped placeholders.
Skip 34 dark equipment-tag routing/value/alarm/write/discovery actor tests with a
shared DarkAddressSpaceReasons constant. Re-key cluster-scoped tests to v3 UNS
line->area attribution.
- ControlPlane.Tests: ConfigComposer round-trips re-keyed to RawFolder/Device (no
Namespaces); tag-config gate resolves driver via Device; deploy-gate collision test
re-keyed to UnsEffectiveNameCollision; drop retired BadCrossClusterNamespaceBinding
case.