b815446940 |
refactor(drivers): delete GetMemoryFootprint / FlushOptionalCachesAsync (#525)
Both `IDriver` members had no production call site. Their only consumer was `MemoryTracking`, deleted with the driver-tier recycle machinery in #522, and `GetMemoryFootprint`'s doc-comment claimed "polled every 30s by Core" — which had not been true since v3, even before #522 removed the poller. Owner decision on #525 was (a) delete rather than (b) build the process-wide watchdog that would consume them. The driver-side implementations are in git history and were mostly reusable; what was always missing is the trigger, and a member nobody calls is how the misleading doc-comment survived this long. Removed from `IDriver`, all 12 driver implementations, and every test stub — plus the support code that existed only to feed them, which is the part a member-only deletion would have left behind as dead weight: - MTConnect's three per-entry byte-weight constants, its cached `ProbeModelDataItemCount`, and `CountDataItems` — a full device-tree walk run on every cache fill to populate a number with no remaining reader. - OpcUaClient's `_discoveredNodeCount` field and the discovery-pass write to it. - MQTT's `ApproxBytesPerAuthoredTag`. Two behavioural notes, neither a change in what the software does: - `AbCipTemplateCache` now has no production reset path. Its only caller was AB CIP's flush, which itself had no caller — so nothing changes except how visible the fact is. Recorded on the type, along with the correction that its comment's claim about a device `ReinitializeAsync` also flushing it was never true. A UDT redefined on a live controller keeps its stale shape until the driver instance is rebuilt. - MTConnect's `/probe` cache is still dropped, by `InvalidateProbeModel()` on an Agent restart. That is now `internal` rather than `private` so the tests which used the flush purely to empty the cache drive the real path instead — they now cover a case that actually occurs in production. Several unrelated doc comments cited `FlushOptionalCachesAsync` as the canonical CAS example and are repointed to it. Tests: the ones that existed only to assert on the removed members are deleted (3 OpcUaClient, 3 Galaxy, 2 MQTT, 1 MTConnect, 1 AbCip). Worth noting one was vacuous — `FlushOptionalCachesAsync_resets_footprint_counter` asserted a footprint of 0 before the flush and 0 after with no discovery in between, so it would have passed against a flush that did nothing at all. Full suite green except 7 failures verified identical on master before and after (4 AbLegacy integration with the compose profile down, 3 Host.IntegrationTests), checked by name rather than assumed. Docs corrected where they described this as live: `DriverLifecycle.md` (which carried the #525 placeholder), `drivers/AbCip.md`, `drivers/AbLegacy.md`, and `v2/driver-stability.md` — whose "polls this every 30 s" + per-driver `DriverConfig` memory budget were never built as written and are now banner-ed as design intent rather than description. Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo |
||
|
|
2d20aeb779 |
fix(opcua,drivers): carry driver status sub-codes to clients (#519) + health-write ordering (#517)
#519 — a driver's OPC UA status code now reaches a client with its sub-code intact. DriverInstanceActor projected the driver's uint onto a 3-state Good/Uncertain/Bad enum and OtOpcUaNodeManager re-expanded Bad to a bare 0x80000000, so BadNoCommunication, BadTypeMismatch and BadNotSupported were indistinguishable on the wire and every driver's status constants (incl. the 16 #497 had just corrected) were diagnostic in logs only. Resolved by option (b): the raw uint rides AttributeValuePublished -> AttributeValueUpdate -> IOpcUaAddressSpaceSink.WriteValue, OpcUaQuality is deleted, and severity classification is a helper (OpcUaStatus.IsGood/IsUncertain/IsBad). The surface was wider than the issue costed (41 files, not "the sink and 3 implementations"): OpcUaQuality had non-driver producers with no uint to carry. Each got its natural code — BadInternalError for a failed virtual-tag script, BadNoCommunication for driver comms loss — and ScriptedAlarmHostActor's pair of mutually-inverse uint<->enum mappers is deleted, having round-tripped a code the engine already held. AddressSpaceApplier's removal writes deliberately keep the generic Bad: not losing a code the driver had is this issue; inventing one for the deploy path is a separate call. Behaviour change: WriteAlarmQuality fires its Part 9 event on a status-code change rather than a severity-bucket change. While the annotation was 3-state those were the same predicate; now a move between two Bad reasons changes what a subscriber reads. New SDK-free named constants live on Commons.OpcUa.OpcUaStatus, and StatusCodeParityTests is widened to cover them — that guard is reflection-driven, so it can only see a named constant, never an inline literal. #517 — the symptom is real but the issue named the wrong path and its fix was unsafe. ShutdownAsync cannot race: DriverInstanceActor calls it from PostStop, after the mailbox drains. (Core/Hosting/DriverHost, the one class with a concurrent GetHealth, has no production call site.) InitializeAsync can: it runs on a fire-and-forget Task.Run, and MTConnectDriver writes Healthy then starts loops that can throw into a catch which disposes the client before writing Faulted. Moving the write earlier, as suggested, inverts the terminal state — teardown drains in-flight loops that write health as they unwind, so a late loop could leave Healthy at rest with every connection closed. The fix is a bracket (conservative before, terminal after), applied to MTConnect's init-failure path only; shutdown keeps its single trailing write, and the rule plus the reachability table are documented on IDriver.ShutdownAsync. CalculationDriver.GetHealth returned a hard-coded Healthy that consulted nothing — Healthy before initialize, after shutdown and after dispose. Now derived from _running. Its test, named Health_is_always_Connected, asserted the defect and is replaced. Every new guard was falsified by breaking the production code and watching it go red. The two sub-code tests each assert two different Bad codes, since a single-code assertion could pass against a hard-coded constant under the old projection. Pre-existing failures, verified unchanged on a stashed tree and not chased: 4 in Driver.AbLegacy.IntegrationTests (slc500/micrologix/plc5 fixtures not up) and 3 in Host.IntegrationTests. Closes #517 Closes #519 Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo |
||
|
|
cbb882293b |
refactor(drivers): delete the inert driver-tier recycle machinery (#522)
The tier system was documented, operator-authorable, and inert. Deleted rather than activated,
because its premise is gone rather than merely unused.
"Tier C" meant a driver running out-of-process behind an IDriverSupervisor that could restart its
Host without tearing down the OPC UA session. No such process exists anywhere: Galaxy reaches
MXAccess over gRPC to the external mxaccessgw sidecar (PR 7.2 retired the in-process
Galaxy.Host/Proxy/Shared projects) and FOCAS has run in-process since its managed wire client
landed 2026-04-24. Consistently, IDriverSupervisor had ZERO implementations and there was nothing
for one to implement against.
The issue understated the inertness. It says the Tier-C-only protections never engaged, implying
the Tier A/B parts did. They did not: nothing constructs MemoryTracking, MemoryRecycle or
ScheduledRecycleScheduler outside their own unit tests, so the whole Core/Stability recycle layer
was dead — meaning option (a), "pass real tiers", was never a flag flip. It would have meant
writing the wiring that never existed AND arming it.
Deleted: MemoryTracking, MemoryRecycle, ScheduledRecycleScheduler, IDriverSupervisor, the
vestigial DriverTypeRegistry (referenced only by its own tests), and the RecycleIntervalSeconds
knob — which the AdminUI let an operator author and the parser validated while it configured
nothing.
DriverTier itself SURVIVES and is load-bearing: DriverResilienceOptions.GetTierDefaults supplies
the real per-capability timeout/retry/breaker policies via DriverFactoryRegistry.GetTier and
DriverCapabilityInvokerFactory. Only the isolation-and-recycle layer above it is gone.
Deliberately NOT deleted:
- WedgeDetector came along in the same directory and is equally dead in production, but it is
tier-agnostic and is not recycle machinery — it only shares the folder. Restored rather than
swept up in a decision that was not about it.
- IDriver.GetMemoryFootprint() and FlushOptionalCachesAsync() lose their only consumer here.
Removing them touches all 12 drivers and every test stub, so they are documented as
consumerless and filed as #525 instead of buried in this diff.
Compatibility: a deployed ResilienceConfig blob still carrying "recycleIntervalSeconds" parses
cleanly (unknown keys are ignored — guarded by a new test, because a blob that suddenly failed to
parse would fall back to tier defaults and silently discard the operator's real overrides), and
the AdminUI's preserve-unknown-keys bag keeps the key rather than rewriting stored config on an
unrelated edit.
The 01/U-6 knob-inertness guard carried an explicit carve-out admitting RecycleIntervalSeconds was
dormant and out of scope; that carve-out is now gone, so the expected set is literally what the
test's name claims.
Note: Host.IntegrationTests has 2 failures (DriverProbeRegistrationTests.is_idempotent,
PrimaryGateFailoverTests) — verified pre-existing by reproducing both on clean master
|
||
|
|
2124f21ab6 |
docs(historian-gateway): document gateway backend, config keys, EnsureTags hook, known gates; retire Wonderware from docs
v2-ci / build (pull_request) Failing after 38s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (pull_request) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (pull_request) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (pull_request) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (pull_request) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (pull_request) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (pull_request) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (pull_request) Has been skipped
HistorianGateway is now the sole historian backend (read + alarm SendEvent + continuous WriteLiveValues). Document the final state and retire the Wonderware sidecar from the docs/config/labels: - CLAUDE.md: rewrite the Historian section — ServerHistorian / ContinuousHistorization / AlarmHistorian config keys, the IHistorianProvisioning EnsureTags hook, the GatewayAlarmHistorianWriter SendEvent path + ReadEvents dependency on gateway RuntimeDb:EventReadsEnabled=true, gateway-side prerequisites (RuntimeDb flags + historian:read/write/tags:write scopes), migration note, and two KNOWN-LIMITATION callouts (live-validation gate + empty historized-ref-set recorder follow-on). - appsettings.json: fix the stale ServerHistorian block (Host/Port/SharedSecret/ ServerCertThumbprint -> Endpoint/ApiKey/UseTls/AllowUntrustedServerCertificate/ CaCertificatePath/CallTimeout, keep MaxTieClusterOverfetch); add a disabled ContinuousHistorization block; prune the orphaned Wonderware keys from AlarmHistorian (keep the SQLite knobs). ApiKey env-supplied via ServerHistorian__ApiKey (commented; valid strict JSON via _comment keys). - README.md + docs (Historian.md, AlarmHistorian.md, Configuration.md, ServiceHosting.md, DriverLifecycle.md, drivers/README.md, Uns.md, VirtualTags.md, AlarmTracking.md, Client.UI.md, README.md, TestConnectProbes.md): retire the Wonderware historian backend from current-backend descriptions; fix the stale ServerHistorian/AlarmHistorian config tables (now gateway shape); convert drivers/Historian.Wonderware.md to a retired stub pointing at the gateway. - Source/UI labels (descriptive text only, no behavior change): OtOpcUaServerHostedService.cs, HistoryPaging.cs, OtOpcUaSdkServer.cs, HistorianAdapterActor.cs, VirtualTagModal.razor, ScriptedAlarmModal.razor, AlarmsHistorian.razor now name the HistorianGateway backend. Build clean (0 errors); AdminUI.Tests green (514 passed). Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii |
||
|
|
1be06502c7 |
fix(historian): correct AlarmHistorian config-key refs in docs + install (review)
v2-ci / build (push) Failing after 43s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
|
||
|
|
33912694fd | docs(audit): G1 completeness — driver-lifecycle + alarm-historian reference pages |