Resolves the 12 reported build errors (7 CS0535 sink fakes + 5 CLI CS1587).
Runtime.Tests green (74). NOTE: OpcUaServer.Tests still has pre-existing CS7036
errors from the in-progress Galaxy-tag workstream (Phase7Plan/Phase7CompositionResult
new required params) — separate, test-only, not addressed here.
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public
members surfaced by commentchecker — resolves 5,847 of 5,869 issues
(99.6%) across three /fixdocs passes.
Phase7Composer now carries UnsAreaProjection + UnsLineProjection lists so
the applier can materialise the full UNS topology in the OPC UA address
space. New IOpcUaAddressSpaceSink.EnsureFolder(folderNodeId, parentNodeId,
displayName) seam (no-op default, recorded in tests, forwarded by
DeferredAddressSpaceSink, implemented by SdkAddressSpaceSink). The SDK-
side OtOpcUaNodeManager gains an EnsureFolder API that creates
FolderState nodes with proper parent linkage; RebuildAddressSpace now
clears folders too so re-applies don't accumulate stale topology.
Phase7Applier.MaterialiseHierarchy walks composition.UnsAreas →
composition.UnsLines → composition.EquipmentNodes, calling EnsureFolder
with the correct parent at each level. Idempotent — calling twice with
the same composition is a no-op. OpcUaPublishActor.HandleRebuild invokes
it after Phase7Applier.Apply so OPC UA clients browsing the server now
see Area/Line/Equipment as proper folders rather than flat tag ids.
DeploymentArtifact.ParseComposition reads UnsAreas + UnsLines from the
JSON snapshot the ControlPlane emits, populating the new fields when
present.
Phase7Composer.Compose now accepts UnsAreas + UnsLines; a 3-arg overload
preserves the old signature for legacy callers + existing tests. The
Phase7CompositionResult convenience ctor likewise keeps the planner
tests working without UNS data.
3 new hierarchy tests (pure unit + boot-verify against a real
OtOpcUaSdkServer); OpcUaServer suite is 48/48 green (was 45, +3),
Runtime 74/74 unchanged.
Closes#85.
Closes the loop between F10b (SDK NodeManager) and F14 (Phase7Plan +
Phase7Applier). DriverHostActor's successful apply now triggers a
RebuildAddressSpace on the publish actor, which loads the latest
deployment artifact + walks composer → planner → applier through the
sink. The OPC UA address space tracks the deployed composition.
DeploymentArtifact:
- New ParseComposition(blob) → Phase7CompositionResult that decodes
Equipment + DriverInstance + ScriptedAlarm arrays into the
projection records Phase7Planner consumes. Pascal-case property
names mirror ConfigComposer.SnapshotAndFlattenAsync's output.
- Each entity reader is tolerant: missing-id rows are dropped,
natural-key sort matches Phase7Composer's contract.
OpcUaPublishActor:
- New Props params: dbFactory + applier. When wired, RebuildAddressSpace
does:
1. LoadLatestArtifact (most recent Sealed Deployment.ArtifactBlob)
2. ParseComposition → Phase7CompositionResult
3. Phase7Planner.Compute(lastApplied, next) → Phase7Plan
4. Empty plan ⇒ no-op (deploy of unchanged composition is benign)
5. applier.Apply(plan) drives sink.RebuildAddressSpace +
WriteAlarmState for removed nodes
6. lastApplied = next so the next rebuild diffs forward
- Without dbFactory/applier wiring, falls back to raw
sink.RebuildAddressSpace — the dev/Mac path before #108 binds prod.
DriverHostActor:
- New Props param opcUaPublishActor (IActorRef?). After successful
ApplyAndAck (status Applied, ACK sent), tells the publish actor
RebuildAddressSpace with the same correlation id so the audit trail
threads through. Null publish actor ⇒ no trigger (admin-only nodes).
Tests: Runtime 63 -> 69 (+6):
- ParseComposition reads Equipment/Driver/Alarm sorted by natural key
- ParseComposition returns empty for empty blob
- Rebuild with dbFactory + sealed deployment artifact triggers exactly
one sink.Rebuild call (Equipment topology added)
- Rebuild with no artifact is idempotent no-op
- Second rebuild with same composition is empty-plan no-op
- Rebuild without dbFactory falls back to raw sink.Rebuild (legacy path)
All 6 v2 test suites green: 173 tests passing.
Closes#109. Engine-wiring data flow is now end-to-end through:
Deploy → DriverHostActor.ApplyAndAck → driver spawn + ACK +
RebuildAddressSpace → OpcUaPublishActor → Phase7Applier → SDK
NodeManager → subscribed OPC UA clients see the change.