Bump ZB.MOM.WW.HistorianGateway.Client + Contracts 1.0.0 -> 1.1.0 (historiangw#135,
release 6365f34). GatewayErrorReasons now reads Client 1.1.0's typed
HistorianGatewayException.StatusCode / ErrorReason / ErrorDomain (constants from
HistorianGatewayErrorReasons) instead of parsing grpc-status-details-bin itself; the
direct Grpc.StatusProto pin and reference are dropped (the client brings it). The
published client maps every RpcException to a HistorianGatewayException, so the
trailer fallback is not needed. Behaviour unchanged: FailedPrecondition +
AGGREGATE_NOT_SUPPORTED_FOR_TAG (domain historian_gateway.v1) ->
BadAggregateNotSupported, everything else keeps its handling.
Adds GatewayErrorReasonsTests (typed-property-only exceptions, so they fail against
the old trailer implementation); wire tests and docs/Historian.md updated.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
LocalDb 0.3.8 ends open sync streams on ApplicationStopping and refuses
new ones Unavailable while stopping (lmxopcua#906, library side). The
host-side ShutdownStreamCancellationInterceptor stays: it also covers
the mesh telemetry/command streams.
GracefulStopWithOpenSyncStreamTests' positive control started passing
the stop in ~950 ms under 0.3.8, because the library alone now ends
the stream. The control registers LocalDbSyncService without the host
lifetime (the 0.3.7 behaviour), so it still reproduces the 8 s drain.
Release build 0 warnings. Host.Tests 288/288, Host.IntegrationTests
350 passed / 2 skipped, Runtime.Tests 1063 passed / 3 skipped,
Core.AlarmHistorian.Tests 53/53.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Two defects on the crash-failover path, found by the T13 live gate on an isolated docker pair:
1. When auto-down removed the unreachable Primary (~15 s after the survivor promoted), the
snapshot's Primary left the unreachable set, so (3') failed and the survivor demoted to
Standby (BadOutOfService, ServiceLevel 50) for ~15 s, until its own singleton published
after the hand-over retries. A Primary that is Down, or that this node saw removed, now
counts as gone (WarmRoleAuthority.SnapshotPrimaryGone). A member that is merely
Leaving/Exiting, or that this node never saw, is not.
2. The verdict read Cluster.State / SelfMember (Akka's ClusterReadView, a separate subscriber
to the same events), which can lag the event being handled. Live, the survivor stayed
Standby 4.3 s after its own UnreachableMember event (promotion waited for the next health
tick). The Warm verdict now uses a membership view built from this actor's own
member/reachability subscription, falling back to the read view only before the first event.
Tests: WarmRoleAuthorityTests.A_snapshot_Primary_that_auto_down_removed_is_still_gone_and_the_survivor_stays_Active,
OpcUaPublishActorWarmTests.The_crash_survivor_promotes_on_its_own_unreachable_event_and_stays_Active_through_the_removal
(synthetic events the read view never sees). Mutations: read-view-only verdict and the removed
arm switched off each fail the actor test. Runtime.Tests 1058 passed, 3 skipped.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
- T3 WarmSingletonHandoverTests: real 2-node cluster, singleton under ClusterSingletonManager on both nodes; the old
incarnation's held-back publish (older revision, higher sequence) reaches a real Warm OpcUaPublishActor after the
handover and never demotes the new Primary. Pin: a removed node cannot rejoin from its old ActorSystem; a new one
rejoins younger (higher up-number).
- T6 DataEncoding: Binary/XML encoded reads of a structured tag projected on the Standby; scalar encoding error kept;
a DefaultXml item is projected, then promoted through its own encoding (TypeId i=888).
- T7 item deleted between queue and publish; ClientHandle reused by i=2267 on a payload recycled through the SDK 2.0.1
pool (precondition asserted); WarmStandbyCloneMatrixTests over DataChange+DiagnosticInfos/EventNotificationList/
StatusChange, clone/cached immutability, encode round-trip, real-pool stale marker.
- T8 ACL-stood-down item receives nothing from demotion or promotion; restored grant reaches it again.
- T10 per-counter MeterListener tests (by instrument instance): warm_transition, warm_role gauge, snapshot_rejected
(publish actor both reasons + DriverHostActor's ordering gate, first actor test of it), projected_notifications,
suppressed_alarm_events. Process-wide state tests run in non-parallel collections.
- Every test mutation-checked (26 mutations killed); no product bug found. Plan status updated.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
- Wire: an event reported while Active but deferred (#838) is delivered after demotion; the promotion refresh
withholds an ACL-denied condition (positive control alongside); ConditionRefresh2 and model-change events on the
Standby; a native Acknowledge is refused and never routed; Warm validates and advertises the EFFECTIVE
ApplicationUri from an ApplicationConfigPath XML load.
- docs/Redundancy.md: Warm section, the Unset/None i=11314 behaviour (orphan readable by NodeId under Unset,
deleted under None), instruments; OpcUaServer.md, Configuration.md, security.md, cluster-topology rule.
- docker-dev/docker-compose.warm.yml for the T13 gate (central pair, Mode=Warm).
- Plan: implementation status and the test gaps left for T13/follow-up.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
A planned stop of the Primary took ~30 s on QA: WebApplication stops the web
server before Akka.Hosting's service, and Kestrel's graceful drain waited the
whole ShutdownTimeout for the peer's open LocalDb sync stream (the library's
LocalDbSyncService only observes the call token, which fires at the END of the
drain). Only then did CoordinatedShutdown run, so the stopping node held the
Primary role and the peer sat at ServiceLevel 240 for the whole window.
- GracefulClusterLeaveService (IHostedLifecycleService): StoppingAsync runs
before any hosted service's StopAsync; it raises ApplicationStopping, then
runs and awaits CoordinatedShutdown with ClrExitReason (not Cluster.Leave,
whose ClusterLeavingReason makes Akka.Hosting set ExitCode -1). The cluster
is left while Kestrel is still up.
- ShutdownStreamCancellationInterceptor (innermost on the shared gRPC
pipeline): every streaming call gets a context whose token is linked with
ApplicationStopping; streams arriving once stopping are refused Unavailable.
Host-side mitigation until LocalDb 0.3.8 is published and pinned
(scadaproj 3ddb083, scadaproj#57); it also covers the mesh streams.
Test GracefulStopWithOpenSyncStreamTests (real WebApplication + Kestrel h2c +
MapZbLocalDbSync + single-node Akka cluster + real peer initiator, 8 s drain
budget): stop 895 ms, cluster left at 892 ms, drain began at 894 ms. Positive
control without the fix: stop 8863 ms, cluster left at 8841 ms after the drain
began at 0 ms. Mutations: no CoordinatedShutdown in StoppingAsync -> order
assertion fails (drain at 1 ms, removed at 893 ms); interceptor passes the
original context -> stop 8006 ms, fails.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
The #815 warn-only compatibility window is over. A running Galaxy driver
(InitializeAsync, every gateway ReopenAsync, the ack fallback password) and a
running OpcUaClient driver (session open) now refuse an out-of-namespace
credential reference with the same CredentialReferenceException that save,
deploy (CredentialReferenceOutOfScope), Test Connect and browse already raise,
before any store / environment / file read and before any endpoint is dialled.
The one existing scope check (CredentialReferences.Parse/ResolveAsync) is now
the only path; nothing new was added.
Removed:
- LegacyCredentialReferenceTracker (Core.Abstractions), its rate-limited WARN
and the credential-compat:<field> diagnostics entry.
- The per-driver Legacy* resolve methods and every `legacy` parameter
(GalaxySecretRef, GalaxyAckCredentialResolver, OpcUaUserIdentityFactory,
OpcUaUserCertificatePaths, OpcUaClientSecretResolution).
- IDriverDiagnostics on GalaxyDriver / OpcUaClientDriver (it only carried the
tracker's entries).
- The tracker also kept a pre-#836 absolute UserCertificatePath loading on a
running OpcUaClient driver; that is refused now too.
Preflight / banner decision: KEPT, as a hard error. The Running source
(driver-health credential-compat entries) and CredentialReferenceBannerModel
are gone with the tracker, but the ConfigDb scan still tells an operator
something no other surface does: a Deployed finding is now a driver that is
not connecting, a Draft finding is a deploy the gate will refuse - named
before anyone deploys, e.g. after restoring an old ConfigDb backup or
importing a pre-#815 config. It also carries the #835 cross-instance and
#836/#850 path checks. CredentialReferencePreflightService now logs one Error
per finding (was Warning) with no warn-only wording, and the /raw banner is
alert-danger.
DEV and QA ConfigDbs hold no Galaxy/OpcUaClient driver (checked 2026-11-13);
no production install exists.
Tests: GalaxyDriverLegacyCredentialTests replaced by
GalaxyDriverCredentialScopeTests; new OpcUaClientDriverCredentialScopeTests;
tracker tests in OpcUaClientSecretResolutionTests /
OpcUaClientUserCertificatePathTests deleted; AdminUI preflight tests drop the
Running/banner-model cases and assert Error level. Against the old code the
new refusal tests fail (Galaxy 5/6, OpcUaClient 4/5; the two positive controls
pass on both).
docs/security.md: the migration table now says running drivers refuse; the
warn-only section is replaced by "The compatibility window is over".
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Root cause: DeploymentDriftProbe (a singleton shared by every circuit) cached its verdict until
the ConfigEdit audit watermark (MAX(EditedAtUtc), COUNT(*)) moved, assuming every configuration
write appends a ConfigEdit row. Only deployments and driver restart/reconnect do; the AdminUI
editors (RawTreeService, UnsTreeService, ScriptEdit, cluster/node/ACL pages) write the config
tables directly. So after a draft change the page kept showing the cached "In sync" until
something unrelated moved the watermark.
- DeploymentDriftProbe: the watermark cache is gone; every verdict comes from a composition that
started after the caller asked. Compositions stay serialised behind the gate, and callers queued
behind one share a verdict only when that composition started after they arrived (start
sequence number) for the same sealed hash, so sharing is exact, never stale.
- Deployments page: the drift check runs in OnAfterRenderAsync (interactive render only, so a
visit costs one composition, not two with prerender); the first render shows a neutral
"Checking for changes..." chip, never a verdict; a failed check shows "Drift check failed" and
logs a warning instead of crashing the page. A deploy re-runs the check.
- Tests: probe tests for an un-audited draft change (real ConfigComposer over InMemory), fresh
composition per call, and queued callers not reusing an older composition; bUnit page tests that
a second page load after a direct draft change shows "Configuration drift" and that the first
render shows "Checking" until the comparison answers. All fail against the previous code.
DeploymentDriftProbeSqlServerTests is removed: it pinned the SQL translation of the watermark
query, which no longer exists.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Closing a tab with the script editor open ended the circuit; MonacoEditor.DisposeAsync then
called MonacoBlazor.dispose through SafeInvokeAsync, which caught only JSDisconnectedException,
so the TaskCanceledException from the torn-down circuit escaped and was logged at [ERR].
DisposeAsync now treats JSDisconnectedException, OperationCanceledException (incl.
TaskCanceledException) and ObjectDisposedException as the expected gone-circuit outcome and logs
them at Debug; a real JSException from a live page is still logged (Warning); the
DotNetObjectReference is released in a finally. MonacoEditor is the only component in the repo
that uses JS interop, so there is nothing else to align.
bUnit tests: dispose throwing each of the three gone-circuit exceptions neither escapes nor logs
above Debug (with a positive control that the failing call ran), and a JSException still warns.
They fail against the previous DisposeAsync.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
A node declared numeric whose AVEVA tag is discrete (or string) is not refused up front by #897, so its native
TimeAverage / Total still reach AVEVA, which refuses them. A HistorianGateway at or after historiangw#135
(a220ec0) answers that FailedPrecondition with a google.rpc.ErrorInfo (reason AGGREGATE_NOT_SUPPORTED_FOR_TAG,
domain historian_gateway.v1) in grpc-status-details-bin. The Gateway backend's native processed read now maps
exactly that to HistoryAggregateNotSupportedException (BadAggregateNotSupported for the node) without recording
a health failure or treating it as transport. Any other FailedPrecondition and every Internal (an older gateway's
answer for the same case) keep today's handling.
Detection lives in one place, GatewayErrorReasons. The HistorianGateway.Client pin stays 1.0.0 (1.1.0 is not on
the feed): 1.0.0 keeps the gateway's RpcException, trailers included, as the InnerException of the
HistorianGatewayException it throws, so the reason is read with Grpc.StatusProto 2.76.0 (added via central
package management; nuget.org; same version as Grpc.Core.Api; depends on Google.Api.CommonProtos 2.16.0, which
accepts Google.Protobuf 3.34.1). With Client 1.1.0, ReasonOf becomes
`(ex as HistorianGatewayException)?.ErrorReason` and the StatusProto reference can go.
Tests:
- GatewayAggregateNotSupportedWireTests: in-process gRPC gateway sending the real status + ErrorInfo shape
(copied from historiangw HistorianRpcFaults.ToRpcException), read through the PUBLISHED Client 1.0.0 via the
production adapter: TimeAverage / Total -> HistoryAggregateNotSupportedException, 0 health failures; controls
(Internal; FailedPrecondition without ErrorInfo; other reason; other domain; the reason on Internal) are
rethrown, not IOException, and counted; positive control served.
- DiscreteTagTimeWeightedWireTests: over a real SDK session, a Double / Int32 node on the discrete tag ->
BadAggregateNotSupported with 0 failures; the older gateway's Internal answer keeps its status and counts.
- AvevaGatewayAggregateRefusalLiveGateTests: opt-in read-only live gate (OTOPCUA_AVEVA_GATE_900=true).
Mutations (catch removed; status ignored; domain ignored; reason ignored; inner-exception walk removed) each
fail at least one test. Release build 0 warnings; Historian.Gateway.Tests 601/607 (6 skipped), OpcUaServer
IntegrationTests 323/361 (38 skipped).
Live, read-only: private HistorianGateway container from a220ec0 (API-key auth disabled, live writes off,
removed after) against wonder-sql-vd03: Double and Int32 nodes on SysPulse, TimeAverage and Total ->
BadAggregateNotSupported, health failures unchanged (0); SysTimeSec TimeAverage Good (2 rows); SysPulse Average
served. Gateway traffic was ReadAggregate / ReadRaw / GetTagMetadata only.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
#899 — EnsureTags is an upsert, so binding a node to an existing AVEVA tag via
historianTagname re-typed/re-described it on every add and host start.
- TagConfig `historianReadOnly: true` (TagConfigIntent -> RawTagPlan.HistorianReadOnly):
HistoryRead from an existing historian tag that OtOpcUa never provisions and never
records into (AddressSpaceApplier.IsOwnedHistorizedValue gates both the EnsureTags
hook and the recorder feed). Node-inert: surgical, not mirrored on UNS refs, in the
RawTagPlan equality/hash. A non-bool value is the deploy error HistorianReadOnlyInvalid.
AdminUI: CSV column HistorianReadOnly (strict), TagHistorizeConfig reads via the
runtime parse.
- ServerHistorian:ProvisionTags = CreateOrUpdate (default, unchanged) | CreateOnly
(Gateway only: TagExistsAsync first, existing tags left alone, failed lookup not
sent) | Off. Unknown value / CreateOnly on a SQL backend fail host start.
- Default for an explicit historianTagname stays OWNED: overrides pin owned history
across renames, a read-only default would silently stop provisioning + recording.
#898 — the hook parsed Tag.DataType (an OPC UA name) as DriverDataType, so historized
Float/Double/Byte/SByte tags were never provisioned. New shared
HistorianDataTypeNames.TryResolve: Float->Float32, Double->Float64, Byte/SByte->Int16
(lossless, provisioned as Int2); unmapped names logged at Information. Gateway now skips
Int64/UInt64 (HistorianGateway cannot create Int8/UInt8: lossless-cast-or-reject).
UPGRADE: the first host start after this provisions (upserts) every existing historized
Float/Double/Byte/SByte tag. Mark foreign-tag bindings historianReadOnly, or set
ServerHistorian:ProvisionTags=CreateOnly/Off, before upgrading (docs/Historian.md).
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
TimeAverage / Total on a Boolean node over the Gateway backend (AVEVA discrete tag, live
SysPulse) went to the gateway since native TimeAverage/Total became default-on (#694). AVEVA
refuses both modes at StartQuery; the gateway reports that only as Internal /
HistorianServerOperationException (the same answer as a historian storage fault), so the
node answered BadHistoryOperationUnsupported and the read counted as a backend failure.
HistoryRead-Processed now checks the node's scalar DataType before calling any backend and
answers BadAggregateNotSupported (Part 11 6.5.4: "If the Aggregate is not valid for the Node
then the StatusCode shall be Bad_AggregateNotSupported"). Nothing is sent, nothing is counted.
- Shared, every backend: HistoryAggregateDataTypes (Core.Abstractions) applies Part 13
5.4.2.3 Table 50: the numeric-only aggregates (Average, TimeAverage(2), Total(2), Min/Max,
ActualTime, Range, Delta, DeltaBounds, Interpolative, stddev/variance) on a String or
DateTime node are refused. Client-visible: the SQL backends used to answer every interval
BadAggregateInvalidInputs.
- Per backend: IHistorianDataSource.SupportsAggregateFor(aggregate, TypeCode?) (default true;
every production backend declares it, guard-tested). Gateway: false for native
TimeAverage/Total on a Boolean node. SqlServer/QuestDb: true, since they serve Boolean as
0/1 (stepped), so Boolean stays served there, as do the Gateway's raw-evaluated aggregates.
The residual case (a node declared numeric whose AVEVA tag is discrete) cannot be told apart
from a historian fault on the wire and still counts; that needs the gateway to surface
AVEVA's native error code as a deterministic status.
Tests: HistoryAggregateDataTypesTests, guard test, node-manager String/DateTime and per-type
refusals, Gateway capability matrix, DiscreteTagTimeWeightedWireTests (production Gateway
backend over an AVEVA-shaped fake: unsent, 0 health failures, positive controls). Each
mutation (no check, no shared rule, no backend hint, Gateway hint true, shared rule always
true, SQL inheriting the default) fails at least one. Live gate re-run read-only against
AVEVA 2023 R2 via a private HistorianGateway fa9cf31 container: SysPulse TimeAverage on the
wire = BadAggregateNotSupported, health failures unchanged; #801 gate 244 cases pass.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
#694 item 3 — historiangw#27 is fixed and now live-verified through OtOpcUa:
- ServerHistorian:Gateway:EnableNativeTimeWeighted defaults to true (false is
the kill switch for a gateway older than 9f711c1). TimeAverage / Total are
served and advertised again (12 aggregates).
- The gateway sends the interval as max(1, round(ms)) and AVEVA clips its last
interval at the request end (live). NativeAggregatePlan therefore sends a
multi-interval grid only for whole-ms intervals; a fractional interval is read
one interval per request (at most 1,000, else BadTooManyOperations), and every
one-interval request goes out rounded UP to whole ms so AVEVA answers one
clipped row. Live, a 3.0004 s clipped interval sent at its own width lost its
last 0.4 ms (Total 123 vs 123.0172).
#746 — HistorianGateway Contracts/Client 1.0.0 surface:
- Alarm history: GatewayAlarmHistorianWriter sends SendEvents batches of <=200.
A failed per-event result is re-sent alone via SendEvent (classified as
before); a refused batch (InvalidArgument etc.) goes event by event so a
poison event dead-letters alone; a systemic fault retries the rest without
sending more; Unimplemented (older gateway) falls back to SendEvent for good.
IHistorianGatewayClient.SendEventsAsync defaults to Unimplemented.
- Events reads: a capped page sends cap + 1 as ReadEventsRequest.max_events, so
the gateway completes the stream instead of the client cancelling it. An
ambiguous capped answer (foreign rows filtered out of the server's cut) or a
refused cap is re-read uncapped with the existing EventDrainBudget drain.
Tests: GatewayServerCappedEventsTests, GatewayAlarmWriterBatchTests,
GatewayNativeWholeMillisecondGridTests (gateway-faithful rounding fake), gate
tests flipped to the new default; every new test mutation-checked (each
mutation of the production change fails at least one). Live harness
AvevaGatewayHistorianFollowupsLiveGateTests (read-only) for #694/#700/#746.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
A UnsTagReference to a raw tag that carries an "alarm" object produced a UNS
value Variable that read BadWaitingForInitialData forever (G6 live gate,
TestAlarm002Condition on testmachine-015). BuildUnsReferenceVariables now skips
those references; the equipment gets the alarm only as the raw condition wired
as an event notifier of its folder, which is unchanged (the reference still
feeds RawTagPlan.ReferencingEquipmentPaths).
Why condition-only and not "feed the mirror":
- The raw side has no value node for such a tag: AddressSpaceApplier
materialises an alarm tag as a condition OR a value variable, never both.
There is no raw value for the UNS mirror to mirror.
- DriverHostActor skips alarm tags when it builds the value fan-out and write
routing maps (`continue` before the UNS registration), and the driver leaves
them out of its value subscription ("subscribed to 5 refs" with 6 tags in
G6). Feeding the mirror would mean subscribing a value the design says the
tag does not have.
- Docs already state condition-only: ScriptedAlarms.md ("instead of a value
variable"), AlarmTracking.md ("only the condition, with no sibling value
variable"), the v3 design (native alarm = one condition at the raw tag,
surfaced at equipment via notifiers).
- The composer tests that asserted the mirror were incidental: f4f3e17e
(v3 B4-WP1) put the alarm on the fixture's Speed tag to test raw alarm
attachment, and later tests reused Speed for writable / historian / array
checks of the mirror. No commit or doc chose a value mirror for alarm tags.
- ScadaBridge does not read it: its OtOpcUa alarm path is event subscriptions
on the equipment/raw folders (v3 alarm B/C live gate), and a node that never
had a value cannot be a working binding. G6 itself authored the alarm's
Boolean as a separate value tag (TestAlarm002), which is the supported way to
read it.
Tests: the composer fixture moves the alarm onto its own HighTemp tag
(Speed is now a plain historized value tag), with a new test asserting no UNS
Variable for the alarm reference, with positive controls (the raw tag still
carries the equipment path; the value references still emit). New real-SDK
test Alarm_bearing_reference_surfaces_as_the_condition_only_against_real_SDK:
no Variable at the UNS path, the Speed mirror present, one condition, the
equipment folder wired as its notifier. Both new tests fail with the skip
removed. Docs: Uns.md, ScriptedAlarms.md, G6 evidence note.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Found on the docker-dev rig during the #761 Wave-4 gate run (2026-11-12): the documented
bodyless headless deploy (docker-dev/deploy.sh, README "Headless deploy") returned 404 on
both centrals, while the same POST with a JSON body was accepted.
Cause: the optional body was an inferred `DeployRequest?` parameter, which stamps
Accepts(application/json) metadata on the endpoint. For a request with no Content-Type the
routing AcceptsMatcherPolicy prefers endpoints that declare no consumes metadata, and on a
fused admin+driver host MapOtOpcUaMeshGrpcServices has mapped grpc-dotnet's
`{unimplementedService}/{unimplementedMethod}` catch-all, so the request was routed away
from the deploy handler and 404'd. The deploy API on its own does not reproduce it.
The handler now reads the optional body itself: no body (absent or zero-length) is the
headless form, a non-JSON body answers 415 and malformed JSON 400, as the framework's
binding did. New DeployApiBodylessPostTests compose the deploy API with the mesh gRPC
services and drive real HTTP; with the fix reverted the two bodyless cases fail with 404.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Pins ZB.MOM.WW.Telemetry(.Serilog) 0.1.0 -> 0.3.0. The OTel Resource now names the
node: site.id = its application Cluster id (the cluster-<ClusterId> role suffix,
omitted on a legacy node), node.role = its plain roles in canonical order
(admin / driver / admin,driver), service.version = the entry assembly's informational
version (the git SHA). Program passes its resolved EffectiveRoles. The whole
OtOpcUa:Telemetry section goes through the shared ApplyConfiguration, so SiteId /
NodeRole / ServiceVersion / ResourceAttributes:* are operator overrides, and
Exporter=Otlp now also sends the Serilog logs to the same collector.
ObservabilityResourceIdentityTests cover the mapping and the built container's
Resource. Host.Tests 288/288, Host.IntegrationTests 325/327 (2 skipped).
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
ZbTelemetryOptions.Meters/ActivitySources are strict allowlists. The host named only
ZB.MOM.WW.OtOpcUa and the LocalDb meter, so the in-process Galaxy driver's galaxy.* spans
and its event pump's galaxy.events.* counters (both on "ZB.MOM.WW.OtOpcUa.Driver.Galaxy")
were silently dropped from /metrics and OTLP. Found exercising OTLP end to end against a
collector (scadaproj#13).
- Galaxy driver: public GalaxyDriverTelemetryNames (MeterName / ActivitySourceName);
GalaxyTelemetry and EventPump reference it.
- Host: ObservabilityExtensions.ObservedMeters / ObservedActivitySources include it.
- Host.IntegrationTests: ObservabilityAllowlistTests assert on the listener side (span
sampled, instrument enabled) with an unregistered-name negative control; dropping the
Galaxy entries fails 3 of 8.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
The installer denied NT SERVICE\OtOpcUaScriptWorker only on -InstallRoot. On the wonder layout the node's keys and
secrets sit beside it (E:\ApiInstall\OtOpcUa\pki with the application certificate's private key, data\ with
secrets.db and LocalDb), inheriting BUILTIN\Users:RX. Users is a restricting SID of the worker token, so a worker
could read them.
- Install-ScriptWorkerIsolation.ps1 -DenyPaths <dir>,...: each folder gets the same inherited deny as InstallRoot
(new SensitiveDirDeny steps). Refuses drive/share roots, script-worker\ and the PE cache; folders must exist;
a comma/semicolon string works for powershell -File.
- The deny is read AND write (0xD0157: ReadData, WriteData, AppendData, WriteEA, DeleteChild, WriteAttributes,
Delete, WRITE_DAC, WRITE_OWNER). Traverse/Execute, ReadAttributes, ReadControl and Synchronize stay so the
loader still reaches script-worker\. The write half stops a worker planting a cert in pki\trusted\certs where
a data drive lets Users create files in subfolders.
- The list is recorded under the anchor service's key (Parameters\DenyPaths, step DenyPathRecord): a re-run
removes the deny from folders dropped from the list, -Uninstall removes every recorded one without repeating
-DenyPaths. -WhatIf/-PlanOnly print every step.
- After an apply, WARN for each protected-DACL item under a denied folder that the inherited deny cannot reach;
without -DenyPaths, WARN for pki/data/logs/backup/config/secrets siblings of InstallRoot.
Tests:
- Dry-run harness 46 -> 86 assertions (QA layout plan, mask bits, refusals, stale removal, record-driven
rollback, host account never denied). Mutations (no sibling deny, deny->allow, mask back to ReadData, no
stale removal, rollback ignoring the record, script-worker not refused) each turn it red.
- Test-ScriptWorkerIsolation.Windows.ps1 (Windows PowerShell 5.1, windev): 34/34, incl. -DenyPaths apply,
11/11 unchanged re-apply, shorter-list re-apply, uninstall from the record, second uninstall unchanged.
- New InstallerLayoutIsolationTests (OTOPCUA_ISOLATION_INSTALLER_E2E=1, elevated Windows): a scratch wonder
layout under the real restricted worker token. Before install and after uninstall the token reads pki/data/
logs/backup/appsettings and plants a trust-list file; installed it can do neither, still reads script-worker\,
a real worker launched from the layout runs a script, and the host still reads everything. Mutating the
-DenyPaths denies to a no-op mask turns it red on pki\own\private\otopcua.pfx (reproduces #890).
QA vq03/vq04 are NOT re-applied; the command is in docs/deploy/qa-upgrade-b8b4c18f-to-fea7de0a.md.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Acceptance runs for #799 (owner scope 2026-11-12: Windows x64 + Linux) on current master.
Fixture: since #808 an UNS folder the authority snapshot does not place is denied under enforcement (fail
closed). The canonical soak creates its own "SoakEquipment" folder but never placed it, so on master the very
first cycle's UNS monitored item came back bad (retained failed Linux launch on b61f3e05, cycle 1). The rig
gains AdditionalFolderScopes (merged into FolderScopes by Enforce) and the soak places its folder there, as a
deployed generation does - the same fixture gap #888 fixed for the SDK matrix. No server authorization code,
cap, baseline or canonical operation changed; the soak test bodies are otherwise byte-identical to b18f9723.
Windows port (test/harness only, opt-in):
- DescriptorCountsAsync gains a Windows branch: total = every handle in the process handle table, PKI = disk
file/directory handles whose GetFinalPathNameByHandle path lies under a canonicalised PKI root; dedicated
thread under the same 5 s bound as the macOS lsof probe.
- Descriptor controls enabled on Windows (symlink alias; timeout control via cmd.exe + ping).
- LateSlopeRun.ValidateRequest accepts Linux ARM64 or Windows x64; duration/runtime/leak tracking unchanged.
- late-slope/analyze.py: expected architecture is a module constant (Linux default Arm64 unchanged).
- windows/: prepare.py (win-x64 self-contained 10.0.14 bundle + manifest), launch.ps1 (container.sh
equivalent: bundle re-verification, 2/2 controls first, PID/apphost/coreclr verification, external
sampler, 7440 s outer deadline), analyze.py (Linux row/window logic, X64), README with every adaptation.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
GalaxyAlarmPriority, the one table live Galaxy alarms (MxAccessSeverityMapper)
and AVEVA A&E history (EventMapper, #886) map the AVEVA priority through, ranked
a higher number as more severe. AVEVA ranks priority 1 as the most urgent, so a
priority-1 alarm read 250 and a priority-999 system event 1000.
It now uses AVEVA's default priority ranges, most urgent first:
AVEVA priority AVEVA severity bucket OPC UA Severity
1-250 1 Critical Critical 1000
251-500 2 High High 750
501-750 3 Medium Medium 500
751-999 4 Low Low 250
(history only) 0 not an alarm - 1
Out-of-range priorities clamp (<= 0 Critical, > 999 Low). Evidence, vd03
Runtime.dbo.Events read-only: priority 1/100 alarms carry AVEVA severity 1,
400/500 severity 2, 600/700 severity 3, and every priority-999 System.* /
User.* row severity 0 with IsAlarm 0.
- Live and history now use the same number. GalaxyDriver passes the table's
exact value as AlarmEventArgs.OpcUaSeverity. Before, it passed only the bucket,
which NativeAlarmProjector re-mapped through its generic 200/500/700/900
ladder, so live and history disagreed even before the direction fix.
- History: a row whose AVEVA severity is 0 (System.Start/Stop/Deploy,
User.Write...) is not an alarm and reads Severity 1, below every alarm band.
For alarms AVEVA's 1-4 severity is still never the value: the live feed
carries only the priority, so it cannot use it, and history must agree.
- Docs: docs/Historian.md gains "Galaxy alarm priority -> Severity
(lmxopcua#887)"; docs/AlarmTracking.md updated.
- Live re-run of the #801/#886 harness against vd03 HistorianGateway
ea9f21c (read-only, network-only): 224 of 233 cases identical to the #886
run, the 9 others differ only in Severity (priority-700 alarm rows 750 ->
500, 19 system/user events 1000 -> 1). Record: aveva-history-801.md
"#887 re-run", report aveva-gate-sdk2-887.json.gz.
Client-visible: every OPC UA client that ranks or filters Galaxy alarms by
Severity sees the order reversed (live and HistoryReadEvents). ScadaBridge has
no code that depends on the old values; its own mixed severity directions are
ScadaBridge#129.
Tests updated because they pinned the inverted table:
- Driver.Galaxy.Tests MxAccessSeverityMapperTests (rewritten: edges 1/250/251/
500/501/750/751/999, 0/-100/int.MinValue/1000/int.MaxValue clamps,
monotonic-decreasing sweep, equals GalaxyAlarmPriority for -2..1001)
- Driver.Galaxy.Tests GatewayGalaxyAlarmFeedTests (750 and 600 -> Medium)
- Driver.Historian.Gateway.Tests EventMapperTests (band table, priority 999
-> 250, 1 -> 1000; system events -> 1)
- OpcUaServer.IntegrationTests GalaxyEquipmentEventHistoryWireTests (700 ->
500, 100 -> 1000, System.Stop -> 1; the fake now stores AVEVA's real 0-4
severity)
New tests:
- Runtime.Tests NativeAlarmRestatementEndToEndTests
.Galaxy_live_condition_severity_is_the_AVEVA_priority_band (8 rows: the real
feed -> real GalaxyDriver -> host -> projector; the same rows EventMapperTests
pins on the history path)
- EventMapperTests.Aveva_severity_zero_marks_an_event_that_is_not_an_alarm
(5 rows, incl. the priority-999 alarm positive control)
- GalaxyDriverAlarmSourceTests: OpcUaSeverity passes through
Mutation check, 8 mutants, all killed: the pre-#887 inverted table; the
driver dropping OpcUaSeverity; no not-an-alarm rule; each of the three band
edges off by one; history ignoring priority; a missing AVEVA severity read
as 0.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
The SDK memoizes INodeManager3.ValidateEventRolePermissions per (item, event type,
SourceNode). #826 kept it fresh by reflecting into the private
MonitoredNode2.InvalidatePermissionCaches (plus a detach/re-attach fallback). Since #855
condition events never take that channel, and the search for #878 found nothing
production-raised that does except a condition's SDK method audits, which reach it only
with auditing on, SignAndEncrypt and a SecurityAdmin session (nothing grants that role).
Under enforcement the channel verdict is now a flat deny for items on our nodes, so no
cached verdict depends on a grant, and InvalidateFolderEventVerdicts, the reflection,
the fallback, its counter and the guard test are removed. Method audits still reach
Server-object items, decided per event.
Tests: FolderEventVerdictInvalidationTests -> FolderEventVerdictFreshnessTests; new
revoked-grant test (positive control: a still-granted session) and method-audit test
(SecurityAdmin mapped for the test; positive controls: Server-object item, flag off);
the plain-event test runs each mode on a fresh server. Mutation-checked.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
A notifier folder read one event source, its NodeId identifier (a RawPath or an EquipmentId). AVEVA stores a
Galaxy object's A&E history under the object's tag_name (Source_Object), so AVEVA's own alarm and event
history reached no production folder. Its lower-case property keys were also missed, so every row read
Severity 1 with no ConditionName.
Sources. A folder's event history now reads its own source plus the Galaxy object of every native condition
that fires on it live: those parented under it and those WireAlarmNotifiers wired to it. Live and history use
the same membership. The object comes from the condition's Galaxy alarm reference, its raw tag's attributeRef,
up to the first '.':
- The composer reads it with the driver's own parser (GalaxyAttributeRef, shared with GalaxyDriver), only for
a GalaxyMxGateway tag with an alarm (RawTagPlan.NativeAlarmReference, part of plan equality).
- The applier binds it after materialising the condition (IOpcUaAddressSpaceSink.BindNativeAlarmHistory,
forwarded by the deferred sink). A rebuild or the condition's removal forgets it.
Each object is read with the #882 rule: its own events and <Object>.<Attribute> rows, never a prefix sibling.
Fan-out. historiangw's ReadEvents filter is a single predicate, so there is one request per source; the wire
contract is unchanged. EventSourceFanOut merges the reads as one source:
- order is (time, source position, arrival), reversed for a reverse read; ties are never re-sorted by EventId,
so the boundary skip stays stable;
- duplicates by EventId are dropped and the merge is cut to the cap;
- a truncated source bounds the page at the time it stopped.
Paging, continuation points (bound to the whole source set), the walked-back reverse read and the tie-cluster
over-fetch are unchanged. A folder with one source is read exactly as before.
ACL. Every source is read inside the folder's own HistoryRead, after AuthorizeHistoryRead (#826). A denied
folder reads nothing and fails closed.
Mapping (EventMapper, property names now case-insensitive):
- Severity: an AVEVA row's priority goes through GalaxyAlarmPriority, the table live Galaxy alarms use
(MxAccessSeverityMapper now delegates to it), so history matches live. Otherwise severity (OtOpcUa's own
rows, which AVEVA stores lower-cased), clamped. AVEVA's own 1-4 severity is ignored. The table ranks a
higher priority as more severe, which inverts AVEVA's convention: filed as #887.
- An AVEVA row whose source_conditionvariable names a native condition that fires on the folder takes that
condition's SourceNode and live ConditionName. Otherwise ConditionName is alarmname or the condition
variable's attribute.
- alarm_id/alarmid map to AlarmId.
Tests:
- GalaxyEquipmentEventHistoryWireTests (4, real SDK session, production Gateway backend, AVEVA-shaped fake
gateway): equipment EqA backed by objects Oven_007 + OvenDoor_07. Covers object and attribute events from
both objects, the prefix sibling excluded, cross-object and in-object ties, forward paging at 1-4 a page,
reverse whole and paged, SourceNode/ConditionName/Severity, the raw device folder, ACL deny with no backend
call plus a granted positive control, and a rebuild forgetting the bindings.
- EventSourceFanOutTests (8), EventMapper AVEVA cases (11), GalaxyAttributeRefTests (16), a composer test and
an applier ordering test.
- Mutation-checked, 17 mutants, all killed. Covered: parent-only membership, no scope, a case-sensitive
condition match, no condition rewrite, no truncation bound, EventId tie order, no sort, no cap, no stop at
the bound, unreversed source order, no dedupe, no '.' boundary, priority ignored, case-sensitive keys, no
applier bind, no deferred forward, and a composer that ignores the driver type. The forget-on-rematerialise
guard survives as belt-and-braces: the rebuild clear covers it.
- Live, read-only, no WinRM, vd03 HistorianGateway ea9f21c: equipment folder EQ-886-ZipsenLeft (objects
DevWinPlatform + Left_001). It read 0 events before and 92 now, equal to the unfiltered read's rows for both
objects. 1/7-event pages and reverse whole/5-event pages agree, and 73 rows resolve to their live condition.
diff_runs vs the #882 run: 221/226 identical. The 5 that differ are expected: DevWinPlatform Severity
1 -> 750/1000, and #881 capabilities.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
ConfigurationBinder appends configured collection items to an existing list, so
the pre-filled [None, Sign, SignAndEncrypt] default made "drop None" a no-op:
every deployment that listed only the secure profiles still advertised an
unsigned/unencrypted None endpoint.
EnabledSecurityProfiles is now null by default; ResolveEnabledSecurityProfiles()
applies the unchanged three-profile default only when nothing is configured.
A set-but-empty list fails startup validation and BuildSecurityPolicies no
longer falls back to a None endpoint on empty input (it throws). Sweep of all
options classes found no other non-empty pre-filled collection default.
Tests: options binding (indexed, JSON, env forms, default, empty, bad name), a
booted-server wire test (no None endpoint, None connection refused with
BadSecurityPolicyRejected, secure connection works; default case is the control).
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
SDK 2.0.1's UserNameIdentityTokenHandler encrypts a password longer than 64 bytes
(a private RsaEncryptedSecretPasswordThreshold, no setting) as an RsaEncryptedSecret
with EncryptionAlgorithm=null. SDK 1.5.378 (.106 and .182) decrypts only the legacy
format under RSA policies; its SecurityPolicies.Decrypt answers a null algorithm with
BadIdentityTokenInvalid ("Unexpected encryption algorithm") before any key check.
Every production API key is 65 chars, so no SDK 2 OtOpcUa client could use one
against QA (b8b4c18f), a rollback target or an older third-party server.
LegacyRsaUserNameIdentityTokenHandler (Driver.OpcUaClient.Session, plugged in through
the public UserIdentity(IUserIdentityTokenHandler) ctor) always uses the legacy
format, RSA-OAEP(len|password|serverNonce) under the server certificate, under an RSA
policy. That is what SDK 2 sends for passwords of 64 bytes or less and what SDK 1.5
clients always send. The legacy format has no size limit (the plaintext is
length-framed over as many RSA blocks as it needs), and an SDK 2 server reads both
formats. Policy None, the ECC policies and a missing certificate go to the SDK
handler unchanged.
OpcUaUserIdentityFactory.UserName is now the one UserName identity the driver, the
AdminUI browse and Client.Shared (CLI/UI) present. Client.Shared references .Session
for it.
Tests: handler unit tests (all three RSA policies, the 1.5-required algorithm URI,
SDK 2 server-side decrypt, the session Copy() keeps the type, None unchanged, and an
SDK control pinning the 64/65-byte switch); a Client.Shared identity test; and an
SDK2<->SDK2 integration test where a 65-char key is admitted in both formats and a
wrong 65-char key reaches the key check (BadIdentityTokenRejected). The #800 Windows
gate's SDK 2 CLI 65-char case now gates against the 1.5 server too.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi