Joseph Doherty f02067d295 test: retry OPC UA host start on a port bind race (TOCTOU in AllocateFreePort)
The tests probe a free port (bind 0, release) and start the SDK server later; under a
highly parallel run another test can take the port in between and the SDK fails with
'Failed to establish tcp listener sockets for Ipv4 and IPv6.'. OpcUaHostStart.StartAsync
builds a fresh host + server on a fresh port per attempt (up to 5) when the failure is a
bind failure; all 45 start sites in OpcUaServer.Tests, OpcUaServer.IntegrationTests and
Runtime.Tests use it. Per-attempt GUID ApplicationUris are hoisted out of the host factory
because a changed URI against a reused PKI store fails with 'Cannot access private key'.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 22:30:55 -04:00
Joseph Doherty 2d20aeb779 fix(opcua,drivers): carry driver status sub-codes to clients (#519) + health-write ordering (#517)
#519 — a driver's OPC UA status code now reaches a client with its sub-code intact.
DriverInstanceActor projected the driver's uint onto a 3-state Good/Uncertain/Bad enum
and OtOpcUaNodeManager re-expanded Bad to a bare 0x80000000, so BadNoCommunication,
BadTypeMismatch and BadNotSupported were indistinguishable on the wire and every
driver's status constants (incl. the 16 #497 had just corrected) were diagnostic in
logs only. Resolved by option (b): the raw uint rides AttributeValuePublished ->
AttributeValueUpdate -> IOpcUaAddressSpaceSink.WriteValue, OpcUaQuality is deleted, and
severity classification is a helper (OpcUaStatus.IsGood/IsUncertain/IsBad).

The surface was wider than the issue costed (41 files, not "the sink and 3
implementations"): OpcUaQuality had non-driver producers with no uint to carry.
Each got its natural code — BadInternalError for a failed virtual-tag script,
BadNoCommunication for driver comms loss — and ScriptedAlarmHostActor's pair of
mutually-inverse uint<->enum mappers is deleted, having round-tripped a code the
engine already held. AddressSpaceApplier's removal writes deliberately keep the
generic Bad: not losing a code the driver had is this issue; inventing one for the
deploy path is a separate call.

Behaviour change: WriteAlarmQuality fires its Part 9 event on a status-code change
rather than a severity-bucket change. While the annotation was 3-state those were the
same predicate; now a move between two Bad reasons changes what a subscriber reads.

New SDK-free named constants live on Commons.OpcUa.OpcUaStatus, and
StatusCodeParityTests is widened to cover them — that guard is reflection-driven, so
it can only see a named constant, never an inline literal.

#517 — the symptom is real but the issue named the wrong path and its fix was unsafe.
ShutdownAsync cannot race: DriverInstanceActor calls it from PostStop, after the
mailbox drains. (Core/Hosting/DriverHost, the one class with a concurrent GetHealth,
has no production call site.) InitializeAsync can: it runs on a fire-and-forget
Task.Run, and MTConnectDriver writes Healthy then starts loops that can throw into a
catch which disposes the client before writing Faulted.

Moving the write earlier, as suggested, inverts the terminal state — teardown drains
in-flight loops that write health as they unwind, so a late loop could leave Healthy at
rest with every connection closed. The fix is a bracket (conservative before, terminal
after), applied to MTConnect's init-failure path only; shutdown keeps its single
trailing write, and the rule plus the reachability table are documented on
IDriver.ShutdownAsync.

CalculationDriver.GetHealth returned a hard-coded Healthy that consulted nothing —
Healthy before initialize, after shutdown and after dispose. Now derived from _running.
Its test, named Health_is_always_Connected, asserted the defect and is replaced.

Every new guard was falsified by breaking the production code and watching it go red.
The two sub-code tests each assert two different Bad codes, since a single-code
assertion could pass against a hard-coded constant under the old projection.

Pre-existing failures, verified unchanged on a stashed tree and not chased: 4 in
Driver.AbLegacy.IntegrationTests (slc500/micrologix/plc5 fixtures not up) and 3 in
Host.IntegrationTests.

Closes #517
Closes #519

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-31 05:25:27 -04:00
Joseph Doherty db751d12a5 feat(alarms): condition Quality tracks source connectivity (#477)
v2-ci / build (pull_request) Successful in 4m49s
v2-ci / unit-tests (pull_request) Failing after 3h11m25s
Part 9 ConditionType.Quality was never assigned; default(StatusCode)==Good
so every native + scripted condition reported Good unconditionally — a
comms-lost device still showed a healthy, inactive, Good condition (a
wrong-VALUE bug, distinct from the null-value #473/#475). Clients (and HMIs
bucketing on IsGood) could not tell "genuinely inactive" from "lost contact".

Layer 1 — make Quality a real, plumbed field:
- AlarmConditionSnapshot gains OpcUaQuality Quality (default Good).
- MaterialiseAlarmCondition sets it (native BadWaitingForInitialData, scripted Good).
- WriteAlarmCondition projects snapshot.Quality; the delta-gate gains a Quality
  member so a quality-bucket change fires a Part 9 event.

Layer 2 — drive native quality from driver connectivity (a comms-lost driver
emits no alarm transitions, and an alarm-bearing raw tag has no value variable,
so quality can't come from either existing channel):
- DriverInstanceActor Tells parent ConnectivityChanged on Connected/Reconnecting.
- DriverHostActor fans it to every native condition the driver owns as
  OpcUaPublishActor.AlarmQualityUpdate (Good on connect, Bad on disconnect).
- New dedicated IOpcUaAddressSpaceSink.WriteAlarmQuality sets ONLY Quality and
  fires only on a bucket change — never touches Active/Acked/Retain (an active
  alarm that loses comms stays active). Not a full-snapshot re-projection, so it
  can't clobber severity/message and works for a never-fired condition.
  Forwarded through DeferredAddressSpaceSink (F10b trap; auto-verified by the
  reflection forwarding guard). Ungated by redundancy role; no /alerts row.

Scripted conditions stay Good; worst-of-input quality deferred to #478 (Layer 3).

Tests: node-level (materialise/project/no-clobber/unknown-node no-op),
NativeAlarmProjector, DriverInstanceActor connectivity emission, DriverHostActor
fan-out, OpcUaPublishActor routing, and the wire-level guard
(Condition_event_Quality_tracks_source_connectivity_on_the_wire) — RED-verified
against a simulated pre-fix always-Good server. Existing DriverInstanceActor
parent probes ignore the new ConnectivityChanged.

Docs: docs/AlarmTracking.md §"Condition source-data Quality (#477)";
design doc docs/plans/2026-07-17-alarm-condition-quality-477-design.md.
2026-07-17 15:10:04 -04:00
Joseph Doherty e08b6b0e69 fix(alarms): populate ConditionClassId/ConditionClassName on conditions (#475)
MaterialiseAlarmCondition never assigned the mandatory Part 9 ConditionType
classification fields, so every condition event — native and scripted — shipped
ConditionClassId = NodeId.Null (i=0) and ConditionClassName = empty text. Same
mechanism as #473: Create() builds the mandatory children from the type's
embedded definition but leaves them unset, and nothing downstream synthesises
them (ReportEvent / InstanceStateSnapshot copy children verbatim). An HMI
bucketing alarms by condition class dropped every OtOpcUa alarm as unclassified.

Report BaseConditionClassType — Part 9's "no condition class modelled" value.
This is the honest report: we hold no classification at the materialise seam.
Deliberately NOT ProcessConditionClassType (the SDK sample's pick), which would
assert a classification we cannot back and would be actively wrong for a Galaxy
alarm whose upstream category is Safety/Diagnostics — trading a detectable null
for an undetectable lie. Real per-alarm classification needs the driver's
AlarmCategory carried to this deploy-time seam (it lives only on the runtime
AlarmEventArgs transition today) and is a separate feature.

Guards, both observed RED against the pre-fix server:
- NativeAlarmEventIdentityFieldDeliveryTests: wire-level, its own select clause
  (the #473 test's clause mirrors ScadaBridge's exactly and its indices are
  load-bearing, so it is left untouched). The class fields are declared on
  ConditionType, not BaseEventType, so they are selected against that type.
- NodeManagerAlarmSourceFieldsTests: node-level, native (Raw) + scripted (Uns).

Stacked on #473 (PR #474) — merge after it.
2026-07-17 00:49:43 -04:00
Joseph Doherty 7339a4af07 fix(alarms): populate EventType/SourceNode/SourceName on conditions (#473)
v2-ci / build (pull_request) Successful in 3m38s
v2-ci / unit-tests (pull_request) Failing after 9m38s
MaterialiseAlarmCondition never assigned the three mandatory BaseEventType
identity fields, so all three arrived null on every condition event — native
and scripted. The SDK does not synthesise them on this path: Create() builds
the children from the type definition but leaves them unset, the auto-filling
BaseEventState.Initialize overload is only used for transient events, and
ReportEvent / InstanceStateSnapshot copy children verbatim. A conforming
client could not attribute an alarm to its source.

  EventType  = the concrete materialised type (TypeDefinitionId)
  SourceNode = the condition's own NodeId (== ConditionId) — the condition IS
               the source; an alarm-bearing raw tag materialises only the
               condition, with no sibling value variable
  SourceName = the same identifying id string: RawPath (native) /
               ScriptedAlarmId (scripted)

SourceName carries the unique id rather than the leaf name: the leaf collides
across devices (HR200 on two PLCs) and is already carried by ConditionName, so
nothing is lost. Documented in docs/AlarmTracking.md, including that clients
must key on ConditionId and must not compose SourceName with ConditionName,
and that SourceName is NOT a live<->history join key (the alarm-history writer
stamps it with the EquipmentPath — a pre-existing divergence, now called out).

Tests: NativeAlarmEventIdentityFieldDeliveryTests is the wire-level guard —
a real client subscription using the standard [EventType, SourceNode,
SourceName, Time, Message, Severity] select clause, verified to fail against
the pre-fix server. NodeManagerAlarmSourceFieldsTests guards the node across
both realms, the base-type fallback, and the kind-swap re-materialise.

The HistoryRead events projection is a separate path (it projects historian
rows, not node fields) and is unaffected — its EventType => Variant.Null
assertions still hold.
2026-07-17 00:36:44 -04:00