Commit Graph

5 Commits

Author SHA1 Message Date
Joseph Doherty 482bafdfac feat(focas): CNC alarms reach Part 9 conditions via ALARM: tags (#647)
An ALARM: address (*, <Type>, <Type>/<n>, <Type>/<lo>-<hi>, T<code>, OTHER) on a raw tag that
also carries the cross-driver alarm object is ONE condition with ConditionId == RawPath and a
Kind (Raise / Retrigger / Clear), so DriverHostActor.ForwardNativeAlarm routes it and
NativeAlarmProjector activates it. Fixes all seven triage defects:

1. SubscribeAlarmsAsync treated the host's RawPaths as device hosts -> nothing polled.
2. Decorated "{host}#{Type}:{Number}" ConditionId -> every event dropped.
3. No Kind -> projector kept prior state.
4. WireFocasClient.ReadAlarmsAsync answered [] on failure -> mass clear + un-acked re-raise.
   It now throws; a failed device read keeps every condition's state.
5. Acks lost on reconnect -> told-record dedup (MTConnect #626 pattern) held for the driver's
   lifetime; same-set re-subscribe / re-init re-raise nothing; changed set prunes leavers only.
6. Subscribe threw while AlarmProjection.Enabled=false -> the tag is the opt-in; flag is a no-op.
7. Alarm tags could not be authored -> ALARM: grammar (FocasAlarmSelector, Contracts) backs the
   editor, the address picker, the deploy-time inspector and driver init.

Severity: authored alarm.severity -> exact OpcUaSeverity; else the 16i-era type bucket. The type
table stays the only one (moved to Contracts, documented 16i-era; 30i codes not invented; raw
T<code> selector + raw code in every message). Read-only: ack is server-side. Also clears the
value table on a re-initialise (#630 gap that let a removed/moved tag keep reading).

E2E: Runtime.Tests FocasNativeAlarmEndToEndTests drives the real driver through the real
DriverHostActor and asserts the condition goes Active then inactive.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:46:48 -04:00
Joseph Doherty b61fe38823 fix(focas): browse-committed fixed-tree tags are readable (Gitea #540)
Authoring FOCAS tags through /raw -> Browse device... produced tags the driver
could never read. Every committed tag read BadNodeIdUnknown forever, and the
failure was silent end to end: the AdminUI accepted it, the deploy gate sealed
green, and the driver reported Healthy with 0 errors while ignoring the tags.
Net effect: the whole fixed-tree surface could not be published through any v3
authoring path. Found cutting wonder-app-vd03 over to v3 against a real Makino
Pro 5 / Fanuc 30i, where 0 of 20 committed tags read while two hand-authored
MACRO: tags on the same device read Good.

A captured browse leaf's id IS its DriverAttributeInfo.FullName, and the fixed
tree emitted "{deviceHost}/{path}" there -- an internal cache key, not an
address. Both authoring paths wrote it verbatim into TagConfig.address, and
FocasAddress.TryParse accepts no such form, so the driver skipped the tags at
init.

Fixed at the emitter rather than by stripping the host at commit, which fixes
the browse-commit flow and the manual picker's tree-select together and leaves
one canonical address form:

- FocasAddress gains a fourth kind, FIXED:<path>, and moves to Contracts so the
  AdminUI and ControlPlane can parse without referencing the runtime driver
  (#526). A FIXED: read is served from the fixed-tree snapshot the poll loop
  already maintains -- no area read, no connection. Writes refuse: nothing in
  that tree is a writable location on the CNC.
- The address carries no device. A tag's device comes from its Device row, and
  a second routing channel for one fact is what created this defect.
- An authored FIXED: tag arms the fixed-tree poll loop by itself. Enabled
  defaults false and the browser force-enables it only for a browse, so the
  operator would otherwise browse, commit, deploy, and land on a driver whose
  loop never starts -- every tag Bad with a correct address.
- Fixed-tree values are now dated from the last answered poll and go
  BadCommunicationError once it is stale (8 cadences, floored at 30s). The poll
  loop swallows a failed tick by design, so a dead CNC would otherwise serve its
  last snapshot as Good indefinitely -- harmless while nothing could bind to the
  tree, not harmless now.

Guardrails, so this class cannot recur silently:

- FocasTagConfigModel.Validate() runs the real parser instead of a non-empty
  check, and FocasTagDefinitionFactory.Inspect() warns at the deploy gate, which
  covers CSV/API config that never touches the modal.
- The manual picker offered axis/spindle/program/status "parameter groups" --
  none of which is a FOCAS addressing space -- and its own default value,
  axis:5, was unusable. It now composes PMC / PARAM: / MACRO: through
  FocasAddress, so what it emits is parseable by construction.

Tests assert addresses ROUND-TRIP through the parser rather than matching an
expected string: the previous FocasAddressBuilderTests pinned "axis:5" exactly,
which is how a green suite coexisted with a picker nobody could use. Verified
red-first against the old emitter. FOCAS 308, AdminUI 1095, ControlPlane 169,
Core 581 -- all pass, 0 warnings.

The remaining half of #540 -- a driver reporting Healthy/0 errors while
skipping tags at init -- is fleet-wide (eight drivers do this) and is filed
separately rather than patched per-driver.
2026-08-05 17:32:18 -04:00
Joseph Doherty 0b4b2e4cfd refactor(historian-gateway): retire Wonderware historian projects (gateway is sole backend)
The HistorianGateway driver is now the sole historian read/write+alarm backend, so the
Wonderware sidecar projects are dead code. Removes the 5 Wonderware projects (driver,
.Client, .Client.Contracts, + their 2 test projects) from the solution and tree, and fully
retires the vestigial 'Historian.Wonderware' driver type (UI/probe-only; it had no driver
factory): the Host probe registration, the AdminUI driver-config surface (driver page,
tag-config editor/model/validator entry, address picker/builder, driver-type catalog +
dropdown + edit-router entries), and their tests. Prunes the now-unused Wonderware
connection fields (Host/Port/UseTls/ServerCertThumbprint/SharedSecret) from
AlarmHistorianOptions (keeping Enabled + the SQLite store-and-forward knobs) and refreshes
the stale XML docs that named Wonderware as the production backend.

Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
2026-06-26 19:25:21 -04:00
Joseph Doherty 3c908f1df0 review(AdminUI): fix null-TagConfig crash, CTS leak, unencoded historian tag
Review at HEAD 7286d320. AdminUI-002: IsValidJson null/blank -> friendly error (was
ArgumentNullException). AdminUI-003: DriverStatusPanel Reconnect/Restart dispose CTS (build-
verified, live /run deferred). AdminUI-005: HistorianWonderware picker URL-encodes tag name.
AdminUI-008: Format round-trip test. 001 (script-page authz) + 004 (hub [Authorize]) left
Open as cross-cutting w/ Host/Security.
2026-06-19 10:52:23 -04:00
Joseph Doherty 063005fefa feat(adminui): DriverTagPicker modal + 9 static address builders
- DriverTagPicker shell: modal chrome + per-driver picker body
  rendered as ChildContent.
- 9 picker bodies (Modbus/AbCip/AbLegacy/S7/TwinCat/FOCAS/
  OpcUaClient/Galaxy/Historian.Wonderware). 5 have computed
  builder logic + unit tests; 4 are free-text passthroughs
  (live browse for OPC UA + Galaxy is a documented follow-up).
- Each typed driver page gets a "Pick address" button that opens
  the modal with the matching body. Picked address surfaces in
  the modal footer for manual copy — no JS interop in v1.
2026-05-28 11:21:33 -04:00