Commit Graph

2 Commits

Author SHA1 Message Date
Joseph Doherty f5475868f7 fix(inspect): trim before the framing check; stop advisories swallowing the backstop (#556); pin the MQTT payloadFormat mode contract (#557 item 2)
#556 item 1 — leading whitespace defeated every Inspect's pre-filter. Seven
factories (Modbus/S7/AbCip/AbLegacy/TwinCAT/FOCAS/Mqtt) tested
`reference[0] != '{'`, so a padded blob returned EMPTY and a tag the driver
refuses deployed clean. The check now trims first, matching the idiom
Sql/Calculation/MTConnect/OpcUaClient already used. The raw reference is still
what is handed to the mapper — the driver reads the stored blob, not a trimmed
copy — so the gate keeps mirroring the runtime rather than becoming lenient.
Both directions are pinned: a padded blob the mapper accepts still draws
nothing, and one that is not object-framed AFTER trimming still draws nothing
(it is not an equipment-tag TagConfig at all).

Six of the seven mappers hand the blob to a whitespace-tolerant
JsonDocument.Parse, so their verdict is unchanged by padding. MQTT is the
exception: both its readers carry the same framing gate, so a padded blob is
genuinely refused — which is why the untrimmed pre-filter was a real defect
there and not a cosmetic mismatch.

#556 item 2 — FOCAS and MQTT appended advisories unconditionally and then gated
the catch-all rejection message on `warnings.Count == 0`, so an advisory (which
fires on ACCEPTED blobs too, and says nothing about a refusal) silently
swallowed the only message naming a refusal nothing else can. The two classes
now accumulate in SEPARATE lists and the backstop gates on the rejection count
alone — structural, not string matching. MQTT's swallow was reachable in
production (a padded blob its readers refuse while every describe branch finds
the parsed document well-formed); FOCAS's backstop is currently unreachable by
audit, so its guard is protective.

#557 item 2 — decided and pinned: KEEP the union verdict. Evidence:
FromSparkplugTagConfig hard-codes PayloadFormat=Json and never consults the key;
only MqttSubscriptionManager (the Plain ingest path) decodes by it; and
MqttTagConfigModel.ToJson deliberately omits the key entirely in Sparkplug mode
(#513). So a Sparkplug driver genuinely serves the tag and rejecting it would be
stricter than the runtime. The cost — served behaviour depends on the driver's
MqttMode, which no tag row records — is paid by an ADVISORY naming the key and
the mode dependency, not by changing the verdict, so both gates keep agreeing.
The same invalid value on a blob the union REFUSES stays a rejection; the class
is decided by the accept gate, never by the key.

Falsified: reverting Modbus's trim reddens the padded-rejection theory;
neutering MQTT's backstop guard to the pre-#556 shape reddens the
advisory-plus-unnameable-rejection test; disabling the #557 advisory reddens the
contract pin; and for FOCAS, removing a describe branch alone stays green (the
backstop covers it) while additionally neutering the guard goes red.
2026-08-10 03:07:18 -04:00
Joseph Doherty 05b424788f fix(tagconfig): close the four #551 residuals — accept-gate-first Inspect, three authoring rules, CSV/service gate, doc sweep
Gitea #551.

1. CSV import ran no driver-typed config gate. Its typed columns were always
   strictly parsed, but the free-form TagConfigJson column reached the database
   unread, so a CSV could author a tag the driver rejects — one that deploys
   green and reads BadNodeIdUnknown forever. RawTagCsvMapper.Parse now names the
   offending row in the staged review grid, and RawTreeService enforces the same
   gate on CreateTag/UpdateTag/ImportTags: a form cannot be the guarantee (the
   API and any future caller reach none of them, and this repo has no bUnit).
   A rejected import row is an ERROR — the batch inserts nothing and the row is
   named — never a skip.

   Note the brief's premise that manual entry rides ImportTagsAsync is wrong:
   RawManualTagEntryModal commits row-by-row via CreateTagAsync, which is why
   the gate had to land on all three write paths.

2/3. The seven pre-#549 Inspect methods ran a hand-list of DescribeInvalidEnum
   checks, so every rejection cause not on the list was invisible. They are now
   ACCEPT-GATE-FIRST (the MTConnect/Sql/OpcUaClient/Calculation shape): ask the
   driver's own reader for the verdict, then explain the refusal, with a
   catch-all so "the parse rejects but Inspect said nothing" is unreachable.
   That closes S7's absent dataType, AbCip members[], Modbus stringByteOrder and
   the type-dependent guards, plus causes the issue did not name (absent
   region/address/tagPath/symbolPath/topic, TwinCAT Structure, MQTT's Sparkplug
   tuple). FOCAS and MQTT keep advisories about ACCEPTED blobs, so they
   diagnose rather than return empty.

   Authoring half: ModbusTagConfigModel gains stringByteOrder;
   AbCipTagConfigModel asks the new AbCipTagDefinitionFactory.DescribeInvalidMember;
   S7TagConfigModel captures whether the SOURCE blob declared dataType and asks
   S7TagDefinitionFactory.DataTypeKey/DeclaresDataType. One authority per rule.

4. Doc sweep: the six factory Inspect summaries, EquipmentTagConfigInspector's
   class remarks and AdminOperationsActor's comment all claimed invalid enums are
   "silently defaulted by the lenient runtime" — false since R2-11 Phase C made
   the runtime reads strict. They describe rejections now.
2026-08-10 00:08:06 -04:00