Capture the original ModbusTagDefinition as _source in ModbusTagRow and
rewrite ToDefinition() to use 'with {}', so StringByteOrder, ArrayCount,
Deadband, UnitId, and CoalesceProhibited survive a load→edit→save cycle.
- DriverTagPicker shell: modal chrome + per-driver picker body
rendered as ChildContent.
- 9 picker bodies (Modbus/AbCip/AbLegacy/S7/TwinCat/FOCAS/
OpcUaClient/Galaxy/Historian.Wonderware). 5 have computed
builder logic + unit tests; 4 are free-text passthroughs
(live browse for OPC UA + Galaxy is a documented follow-up).
- Each typed driver page gets a "Pick address" button that opens
the modal with the matching body. Picked address surfaces in
the modal footer for manual copy — no JS interop in v1.
- AdminProbeService routes TestDriverConnect through
IAdminOperationsClient with a 65s outer guard (actor side already
clamps to [1,60]).
- Added generic AskAsync<T> to IAdminOperationsClient interface and
AdminOperationsClient impl, delegating straight to the Akka proxy.
- DriverTestConnectButton renders the button + inline result chip,
auto-clears after 30s, disables during in-flight.
- Wired into all 9 typed driver pages directly under the
identity section. Sources timeout from the form's
ProbeTimeoutSeconds; sources config JSON from the form's
current Options (operator can test BEFORE saving).
Live panel subscribed to the /hubs/driverstatus SignalR feed —
renders state chip, last-success age, 5-min error count, last
error message. Auto-reconnect; dimmed when no push arrives for 30s.
Hidden for new instances (nothing deployed yet); shown read-only
on every edit-mode page. Reconnect/Restart buttons land in Phase 8.