Task 14/15/16: each picker body keeps its manual builder and appends a DriverOperator-gated
browse affordance (mirrors OpcUaClientAddressPickerBody) — Browse/Refresh/Close, DriverBrowseTree
over the universal DiscoveryDriverBrowser session, leaf-only commit (OnNodeSelected fires for
folders too), snapshot-at-open label, fire-and-forget close on dispose. _canBrowse evaluated once
in OnInitializedAsync (CanBrowse constructs a throwaway driver). FOCAS commits the leaf FullName
directly (the group/id builder can't reconstruct it). Editors pass DriverType + GetConfigJson
through. Razor-live-verified at Task 18.
Adds <summary>/<param>/<returns>/<inheritdoc> where missing and removes
project bookkeeping IDs (task/tracking refs) from shipped code comments,
so the docs read cleanly and CommentChecker is quiet except for known
false positives (PLC/protocol terms, event/IEqualityComparer inheritdoc).
Doc/comment-only; no logic changed; solution builds clean.
The HistorianGateway driver is now the sole historian read/write+alarm backend, so the
Wonderware sidecar projects are dead code. Removes the 5 Wonderware projects (driver,
.Client, .Client.Contracts, + their 2 test projects) from the solution and tree, and fully
retires the vestigial 'Historian.Wonderware' driver type (UI/probe-only; it had no driver
factory): the Host probe registration, the AdminUI driver-config surface (driver page,
tag-config editor/model/validator entry, address picker/builder, driver-type catalog +
dropdown + edit-router entries), and their tests. Prunes the now-unused Wonderware
connection fields (Host/Port/UseTls/ServerCertThumbprint/SharedSecret) from
AlarmHistorianOptions (keeping Enabled + the SQLite store-and-forward knobs) and refreshes
the stale XML docs that named Wonderware as the production backend.
Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
Audit (task #134) found the same Razor literal-binding bug class as the UNS
Filter fix (14b4692): a string-typed component parameter assigned without a
leading @ is a LITERAL, not an expression. Confirmed against the generated
.g.cs (literal "_error" vs TypeCheck<String>(_error)).
- DriverFormShell Error="_error" -> "@_error" on all 9 driver edit pages:
Error received the constant "_error", so the error banner rendered
permanently and the real failure message was never shown.
- DriverBrowseTree SelectedNodeId="_tagName"/"_nodeId" -> "@..." in the
Galaxy and OpcUaClient address pickers: the tree's selected-node highlight
compared against a literal that never matched a real node.
Build clean; generated code now binds all 11 as TypeCheck<String>(field);
AdminUI.Tests 216/216 green.
The driver/factory/seed use 'GalaxyMxGateway' (legacy 'Galaxy' was retired),
but the AdminUI editor router, GalaxyDriverPage, address picker, identity
dropdown, the Galaxy browser/probe, and DraftValidator still keyed on 'Galaxy'.
Result: the seeded GalaxyMxGateway driver couldn't be edited ('no editor
registered'), UI-created Galaxy drivers wrote a type with no factory, and a
SystemPlatform-bound GalaxyMxGateway driver failed publish validation.
Align all stragglers to GalaxyMxGateway (+ failing-test-first DraftValidator
coverage). ShouldStub's 'Galaxy' legacy safety-net left intact.
- DriverTagPicker shell: modal chrome + per-driver picker body
rendered as ChildContent.
- 9 picker bodies (Modbus/AbCip/AbLegacy/S7/TwinCat/FOCAS/
OpcUaClient/Galaxy/Historian.Wonderware). 5 have computed
builder logic + unit tests; 4 are free-text passthroughs
(live browse for OPC UA + Galaxy is a documented follow-up).
- Each typed driver page gets a "Pick address" button that opens
the modal with the matching body. Picked address surfaces in
the modal footer for manual copy — no JS interop in v1.