ConfigurationBinder appends configured collection items to an existing list, so
the pre-filled [None, Sign, SignAndEncrypt] default made "drop None" a no-op:
every deployment that listed only the secure profiles still advertised an
unsigned/unencrypted None endpoint.
EnabledSecurityProfiles is now null by default; ResolveEnabledSecurityProfiles()
applies the unchanged three-profile default only when nothing is configured.
A set-but-empty list fails startup validation and BuildSecurityPolicies no
longer falls back to a None endpoint on empty input (it throws). Sweep of all
options classes found no other non-empty pre-filled collection default.
Tests: options binding (indexed, JSON, env forms, default, empty, bad name), a
booted-server wire test (no None endpoint, None connection refused with
BadSecurityPolicyRejected, secure connection works; default case is the control).
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Re-runs only the ScriptWorker step on windev (master da948e5f, SDK 2.0.1, 16 vCPUs): install as the OtOpcUaHost service,
repo Install-ScriptWorkerIsolation.ps1 applied/re-applied/uninstalled twice under pwsh 7 and Windows PowerShell 5.1,
restricted worker, pipe refuses the admin, runner Healthy, strict-peer/API-key matrix on, then cleanup. The harness drops
-PatchedIsolation, gains -PrepareFrom candidate and -ApplyHost, and suffixes the isolation evidence with -Label.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
The baseline is 83ed880e (SDK 1.5.378.182). The candidate is the #880 change (on da948e5f), run twice.
Fixed: every SDK 2 client (Shared, OpcUaClient driver, CLI) logs in to the SDK 1.5
server with a 65-char key. A wrong 65-char key gets BadIdentityTokenRejected. In the
control, the SDK default handler is refused by 1.5 with BadIdentityTokenInvalid and
admitted by SDK 2.
Mutation (the factory reverted to the SDK default handler): the SDK 2 Shared connect,
the driver connect and all three CLI calls fail against 1.5 with
BadIdentityTokenInvalid, and the wrong-key case gets Invalid instead of Rejected. This
is #880 reproduced.
In both runs the UNS cases fail against the master server for every client SDK. That
is a fixture gap since #808 and is tracked as #888.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
The cross-version matrix (#782) used a 55-char 'otua_matrix_' key, which stayed under
SDK 2's 64-byte RsaEncryptedSecret threshold and hid #880. It now uses the
ApiKeySecret.Generate shape (65 chars, random per run, never recorded). Every Shared
leg adds production-length-API-key-wrong-secret-reaches-key-check, which must get
BadIdentityTokenRejected rather than a format failure. SDK 2 clients also add
sdk2-default-RsaEncryptedSecret-control, the negative control: the SDK's default
handler must be refused with BadIdentityTokenInvalid by a 1.x server and admitted
by an SDK 2 server. The runner passes the server SDK version from ready.json.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
SDK 2.0.1's UserNameIdentityTokenHandler encrypts a password longer than 64 bytes
(a private RsaEncryptedSecretPasswordThreshold, no setting) as an RsaEncryptedSecret
with EncryptionAlgorithm=null. SDK 1.5.378 (.106 and .182) decrypts only the legacy
format under RSA policies; its SecurityPolicies.Decrypt answers a null algorithm with
BadIdentityTokenInvalid ("Unexpected encryption algorithm") before any key check.
Every production API key is 65 chars, so no SDK 2 OtOpcUa client could use one
against QA (b8b4c18f), a rollback target or an older third-party server.
LegacyRsaUserNameIdentityTokenHandler (Driver.OpcUaClient.Session, plugged in through
the public UserIdentity(IUserIdentityTokenHandler) ctor) always uses the legacy
format, RSA-OAEP(len|password|serverNonce) under the server certificate, under an RSA
policy. That is what SDK 2 sends for passwords of 64 bytes or less and what SDK 1.5
clients always send. The legacy format has no size limit (the plaintext is
length-framed over as many RSA blocks as it needs), and an SDK 2 server reads both
formats. Policy None, the ECC policies and a missing certificate go to the SDK
handler unchanged.
OpcUaUserIdentityFactory.UserName is now the one UserName identity the driver, the
AdminUI browse and Client.Shared (CLI/UI) present. Client.Shared references .Session
for it.
Tests: handler unit tests (all three RSA policies, the 1.5-required algorithm URI,
SDK 2 server-side decrypt, the session Copy() keeps the type, None unchanged, and an
SDK control pinning the 64/65-byte switch); a Client.Shared identity test; and an
SDK2<->SDK2 integration test where a 65-char key is admitted in both formats and a
wrong 65-char key reaches the key check (BadIdentityTokenRejected). The #800 Windows
gate's SDK 2 CLI 65-char case now gates against the 1.5 server too.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Adds scripts/validation/opcua-windows-service/: a phased PowerShell gate (Invoke-ServiceGate.ps1)
that installs the known-good build as the real OtOpcUaHost service via Install-Services.ps1, seeds
LocalDb through the production cache API (Seeder, built against the baseline tree), upgrades in
place with config/PKI/LocalDb carried with their ACLs, starts/stops through the SCM, runs a strict
SDK 2 probe matrix (Sign + SignAndEncrypt, valid/wrong/unknown/disabled/anonymous keys, untrusted
client and server), exercises the ScriptWorker isolation, rolls back and cleans up.
windev 2026-11-12 (efb9197a -> 438484fd -> efb9197a): app cert CEF9D91F... reused byte-for-byte
with identical PKI SDDL on every start, all gating checks pass, 0 secrets in logs. Findings filed:
#879 (None endpoint cannot be dropped), #880 (SDK 2 client 65-char key vs SDK 1.5 server:
rollback/QA risk), #883 (Install-ScriptWorkerIsolation.ps1 fails on pwsh 7 and 5.1; runtime
isolation proven with the patch in the evidence directory).
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Console helper that mints and revokes OPC UA API keys through the same IApiKeyAdminService the AdminUI
/apikeys page calls, edits NodeAcl grants in the rig ConfigDb, and holds one OPC UA session open per node
(Client.Shared) with a subscription plus a read/write every 3 s, so a revocation, expiry or grant removal
can be observed landing on an ALREADY-OPEN session on both pair nodes next to a non-revoked control key.
Credentials go to a 0600 file and are never printed. LOCAL docker-dev only.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
AvevaGatewayHistoryLiveGateTests boots the server in-process, wires the production
Gateway backend (HistorianBackendRegistry -> GatewayHistorianDataSource) to a real
HistorianGateway and drives HistoryRead over a real SDK session: raw (all, paged,
reverse, bounds), modified, the ten served aggregates and seven refused ones, AtTime,
events (all, 1-event pages, reverse), a missing tag, HistoryServerCapabilities and
node metadata, and a HistoryUpdate that must be refused (sandbox-bound node only).
Every wire answer is compared with the backend's direct answer; the run is dumped as
JSON for cross-SDK and SQL comparison. Skips unless HISTGW_GATEWAY_ENDPOINT and
HISTGW_GATEWAY_APIKEY are set; read-only by construction.
scripts/validation/aveva-history-801: run/compare instructions, the SDK 1.5.378
baseline port patch (API spelling only), and the diff / SQL / aggregate / histgw-cli
comparison scripts.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Probe 'failover <primary> <backup> <mode> <dir>' drives ScadaBridge's own DataConnectionActor
(production primary/backup machine, real DataConnectionFactory, default DataConnectionOptions,
FailoverRetryCount 3) against two servers; run.py loses the primary (SIGKILL or SIGSTOP) once the
probe reports a steady primary, and the probe requires Bad quality on loss, "Connected to backup",
the backup's own value, a fresh ConditionRefresh replaying the native condition, and a write via the
backup. rig-failover.sh runs the same probe against the local docker-dev central pair.
Matrix legs gain a UNS subscription case and a Server-object alarm subscription on the reconnected
session whose ConditionRefresh must replay the active condition (11 cases). run.py gains --versions,
--suites, --failover-modes and --failover-loss.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Probe 'prepare' provisions the consumer identity via OpcUaApplicationIdentity.EnsureApplicationCertificateAsync
and exports the public DER; runner installs it in the server trusted store before start. Adds Sign
(OPCUA_MATRIX_SERVER_SECURITY=sign), untrusted-client / untrusted-server fail-closed controls per secure
mode, and OPCUA_MATRIX_ACL=off. Autoaccept stays false everywhere.
Scripted condition NodeIds are opaque ScriptedAlarmIds, so splitting them as a
topology path could never match an Equipment grant: a narrow equipment grant was
denied while a Cluster grant passed.
- OtOpcUaNodeManager binds each LIVE scripted condition instance to the
EquipmentId it was materialised under (only when it hangs under that folder);
dropped on remove / drop-recreate / equipment-subtree removal / rebuild; a
same-id re-materialise under another equipment re-parents and re-binds.
- DataPlaneAuthoritySnapshot carries EquipmentScopePaths (EquipmentId ->
[uns, Area, Line, Equipment]) decoded from the artifact by the same
AclScopePathResolver call that plants Equipment grants.
- DataPlaneAuthorizer.AuthorizeScriptedCondition re-reads key, grant and
generation per call (uncached) and evaluates at the owner path; unbound,
replaced or unplaceable owners deny under every grant. No id-split or
realm-root fallback.
- Native conditions (RawPath) and the ACL-off role gate are unchanged.
NodeIds and AlarmCommand.AlarmId are unchanged.
Sdk2OpaqueScriptedScopeBaselineTests deliberately flipped: it pinned the denial
and now pins owner-grant allow / sibling deny / cluster allow. Follow-up #808