AdminUI driver-instance pages serialized enum config fields (S7 CpuType,
Modbus DataType/Region, AbCip PlcFamily, ...) as JSON *numbers* because each
page's _jsonOpts lacked a JsonStringEnumConverter. The driver factories,
however, deserialize into string-typed DTOs (+ lenient ParseEnum) and throw
when binding a JSON number to a string? — so an AdminUI-authored config
containing any enum field produced a blob the driver could not parse,
faulting the driver on deploy. Proven end-to-end for S7 and Modbus; latent
for AbCip/AbLegacy/TwinCAT/FOCAS/Galaxy/Historian. Only OpcUaClient was safe
(its factory + probe already carried the converter).
Add JsonStringEnumConverter to all 9 driver-instance pages' _jsonOpts and the
8 missing driver probes' _opts (factories unchanged — already string-via-
ParseEnum; strictly more permissive, also lets pages load hand-seeded
string-enum configs back into the form).
Also fix DriverProbeHandshakeE2eTests.AbCip_Green_AgainstSim to probe a real
sim tag (TestDINT) — the no-tags @raw_cpu_type fallback is rejected by the
ab_server sim with ErrorBadParam (a real ControlLogix returns ErrorNotFound,
which the probe treats as reachable; hardware-gated follow-up).
Tests: reflection guard over all driver pages' _jsonOpts (AdminUI.Tests);
factory round-trip + numeric-form-throws guards for S7 and Modbus.
Found by running the never-before-run FB-9/FB-10 live verifies.
Code-review nits: trim the seed name so the in-session dropdown label matches
the server-trimmed persisted name; add a null-selectedId test for
ResolveScriptLabel; and note in CreateNewScriptAsync that the ordering
invariant is proxied by the pure helper (AdminUI has no bUnit).
After inline "New script" creates an SC-… id, the entry is now added
to _scripts BEFORE _form.ScriptId is set so the <InputSelect> has a
matching <option> on first render and the displayed label is correct.
Extracts VirtualTagModalHelpers.ResolveScriptLabel as a testable pure
helper (5 new unit tests in VirtualTagScriptDropdownTests).
The OPC UA address-space build pipeline was named after a v2-roadmap
milestone number rather than its domain. Rename the family to describe
what it does (build/diff/apply the OPC UA address space):
Phase7Composer -> AddressSpaceComposer
Phase7CompositionResult -> AddressSpaceComposition
Phase7Planner -> AddressSpacePlanner
Phase7Plan -> AddressSpacePlan
Phase7Applier -> AddressSpaceApplier
Phase7ApplyOutcome -> AddressSpaceApplyOutcome
The 9 Phase7*Tests suites follow suit; Phase7ScriptingEntitiesTests ->
ScriptingEntitiesTests (it tests the scripting migration, not the
pipeline). Log-message prefixes move to the new class names.
Pure mechanical rename, no behavioral change. EF migration classes/IDs
(AddPhase7ScriptingTables, ExtendComputeGenerationDiffWithPhase7) are
immutable and left untouched, as are historical design docs.
Build clean; OpcUaServer 261/261, Runtime 272/272, ScriptingEntities
12/12 green.
Subscribe ConnectionStateChanged before reading IsConnected (subscribe-then-read
idiom, matches DriverStatusPanel) so no transition is missed. Add
OnConnectionStateChanged handler that marshals to the circuit sync context via
InvokeAsync. Dispose unsubscribes both events.
Reconnect-overlay: App.razor loads _framework/blazor.web.js and contains no
custom #components-reconnect-modal element; .NET 10 Blazor's default reconnect
overlay is active automatically — no custom markup needed.
No unit tests; live-verify follows.
Dispose the CancellationTokenSource in AcknowledgeAsync and ShelveAsync
(the TimeSpan overload holds an internal timer — leaked without using).
Add StateHasChanged() to ShowOpResult so the result chip renders even if
a future caller omits the finally-block re-render.
T21: add an AdminUI path for acknowledging/shelving alarms that routes
through the admin-pinned AdminOperationsActor cluster singleton, which
republishes onto the same 'alarm-commands' DPS topic the OPC UA method
path (T18) and the engine subscriber (T19) use. The broadcast + the
ScriptedAlarmHostActor ownership filter handle cross-node routing, so
the singleton needs no knowledge of which node owns the alarm.
- Commons: AcknowledgeAlarmCommand/ShelveAlarmCommand (+ result records)
and a shared AlarmCommandsTopic const; ScriptedAlarmHostActor now
re-exports that const (mirrors the DriverControlTopic pattern).
- AdminOperationsActor: two handlers map the control-plane messages to
AlarmCommand (Acknowledge / OneShotShelve / TimedShelve / Unshelve,
threading User/Comment/UnshelveAtUtc) and publish via the DPS mediator.
- IAdminOperationsClient + AdminOperationsClient: typed Acknowledge/Shelve
ask wrappers mirroring StartDeploymentAsync.
- Alerts.razor: per-row DriverOperator-gated Ack/Shelve/Unshelve controls;
operator name from AuthenticationState. Timed-shelve datetime UI deferred.
- 5 TestKit tests (mediator-probe subscribed to alarm-commands) verifying
each kind's mapping + reply; 56/56 ControlPlane tests green.
ScriptId is now system-generated on create (mirrors EquipmentId's EQ-{12 hex}
convention, never operator-supplied) and shown read-only when editing. Language
is always CSharp, so the single-option dropdown is removed entirely and set on
save.