Commit Graph

4 Commits

Author SHA1 Message Date
Joseph Doherty
41a6b66943 Apply code style formatting and restore partial modifiers on Avalonia views
Linter/formatter pass across the full codebase. Restores required partial
keyword on AXAML code-behind classes that the formatter incorrectly removed.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-03-31 07:58:13 -04:00
Joseph Doherty
4833765606 Expand XML docs across bridge and test code 2026-03-25 11:45:12 -04:00
Joseph Doherty
09ed15bdda Fix second-pass review findings: subscription leak on rebuild, metrics accuracy, and MxAccess startup recovery
- Preserve and replay subscription ref counts across address space rebuilds to prevent MXAccess subscription leaks
- Mark read timeouts and write failures as unsuccessful in PerformanceMetrics for accurate health reporting
- Add deferred MxAccess reconnect path when initial connection fails at startup
- Update code review document with verified completions and new findings
- Add covering tests for all fixes

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-03-25 09:41:12 -04:00
Joseph Doherty
a7576ffb38 Implement LmxOpcUa server — all 6 phases complete
Full OPC UA server on .NET Framework 4.8 (x86) exposing AVEVA System
Platform Galaxy tags via MXAccess. Mirrors Galaxy object hierarchy as
OPC UA address space, translating contained-name browse paths to
tag-name runtime references.

Components implemented:
- Configuration: AppConfiguration with 4 sections, validator
- Domain: ConnectionState, Quality, Vtq, MxDataTypeMapper, error codes
- MxAccess: StaComThread, MxAccessClient (partial classes), MxProxyAdapter
  using strongly-typed ArchestrA.MxAccess COM interop
- Galaxy Repository: SQL queries (hierarchy, attributes, change detection),
  ChangeDetectionService with auto-rebuild on deploy
- OPC UA Server: LmxNodeManager (CustomNodeManager2), LmxOpcUaServer,
  OpcUaServerHost with programmatic config, SecurityPolicy None
- Status Dashboard: HTTP server with HTML/JSON/health endpoints
- Integration: Full 14-step startup, graceful shutdown, component wiring

175 tests (174 unit + 1 integration), all passing.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-03-25 05:55:27 -04:00