Part 1 — rewire the three DriverType dispatch maps from hand-authored string
literals to the canonical DriverTypeNames constants (single source of truth):
- TagConfigEditorMap, TagConfigValidator (AdminUI)
- EquipmentTagConfigInspector (ControlPlane)
This FIXES the live drift ("TwinCat"->TwinCAT, "Focas"->FOCAS). The maps are
OrdinalIgnoreCase so behavior is identical; the value is no future drift.
Calculation is not added to the inspector (no CalculationTagDefinitionFactory.Inspect).
Added TagConfigDriverTypeNameGuardTests pinning the maps to the constants.
Part 2 — retire the routed /clusters/{id}/drivers driver-authoring flow (/raw
Waves A-C now cover driver/device/tag authoring end-to-end):
- Deleted DriverTypePicker, DriverEditRouter, the 8 *DriverPage shells, and the
ClusterDrivers list page.
- Removed the "Drivers" tab from ClusterNav. Routes /clusters/{id}/drivers* now
simply do not exist -> clean 404.
- The Forms/DeviceForms bodies, shared driver sections, and address pickers used
by the /raw modals are untouched.
Part 3 — updated PageAuthorizationGuardTests census: removed the 10 deleted
ConfigEditor pages + ClusterDrivers, updated group-count comments (ConfigEditor
21->11, AuthenticatedRead 17->16). Removed the now-dead Clusters.Drivers usings
from the 4 *DriverPageFormSerializationTests + the guard test.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
Extract the 8 typed driver pages into embeddable <Driver>DriverForm bodies
(channel/protocol config) and add per-driver <Driver>DeviceForm bodies
(connection endpoint -> Device.DeviceConfig, v3 endpoint split). New
DriverConfigModal + DeviceModal dispatch by DriverType (DriverTypeNames) for
the /raw tree; Test-connect inside DeviceModal builds the merged Driver+Device
config transiently via DriverDeviceConfigMerger. Routed pages now host the
form bodies and keep working. Round-trip + enum-serialization guard tests for
the Modbus driver form + Modbus device model; retargeted the existing
page-form serialization tests + the _jsonOpts converter guard to the forms.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
Namespace entity + NamespaceKind retired; DriverInstance dropped NamespaceId;
Tag is raw-only (no EquipmentId/DriverInstanceId/FullName/FolderPath); driver
options replaced pre-declared Tags with RawTags. Stub the retired surfaces so
the AdminUI + Host build green; real Raw/UNS authoring arrives in v3 Batch 2/3.
- ClusterNamespaces/NamespaceEdit: bodies replaced with 'Namespaces retired' banner
- DriverIdentitySection: dropped Namespace dropdown + NamespaceId model field
- 8 driver pages: dropped Namespace binding; retired the pre-declared Tags editor
(replaced with a '/raw Batch 2' note); multi-device pages keep their Devices editor
- UnsTreeService: equipment-tag counts/list -> empty; Create/UpdateTag -> failure
result ('Tag authoring moved to the Raw tree (/raw) in v3 Batch 2'); Namespace/
driver-binding queries removed
- IScriptTagCatalog: project surviving Tag columns only (path from TagConfig FullName, else Name)
- OpcUaClientTagConfigEditor: rebind stale FullName -> model's NodeId
- ClusterDrivers: drop retired NamespaceId column
AdminUI + Host build 0/0. AdminUI.Tests / Host.IntegrationTests remain red (WP6).
AbCip/TwinCAT/FOCAS driver-config pages host the same *AddressPickerBody as the /uns TagModal but
did not pass GetConfigJson, so their universal Browse button would capture against an empty {} (no
device). Thread SerializeCurrentConfig through. DriverType is left to the picker-body default
(canonical registered type) rather than the page's DriverTypeKey const, whose TwinCAT/FOCAS values
("TwinCat"/"Focas") are non-canonical casing that could miss the factory TryCreate lookup.
The HistorianGateway driver is now the sole historian read/write+alarm backend, so the
Wonderware sidecar projects are dead code. Removes the 5 Wonderware projects (driver,
.Client, .Client.Contracts, + their 2 test projects) from the solution and tree, and fully
retires the vestigial 'Historian.Wonderware' driver type (UI/probe-only; it had no driver
factory): the Host probe registration, the AdminUI driver-config surface (driver page,
tag-config editor/model/validator entry, address picker/builder, driver-type catalog +
dropdown + edit-router entries), and their tests. Prunes the now-unused Wonderware
connection fields (Host/Port/UseTls/ServerCertThumbprint/SharedSecret) from
AlarmHistorianOptions (keeping Enabled + the SQLite store-and-forward knobs) and refreshes
the stale XML docs that named Wonderware as the production backend.
Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
AdminUI driver-instance pages serialized enum config fields (S7 CpuType,
Modbus DataType/Region, AbCip PlcFamily, ...) as JSON *numbers* because each
page's _jsonOpts lacked a JsonStringEnumConverter. The driver factories,
however, deserialize into string-typed DTOs (+ lenient ParseEnum) and throw
when binding a JSON number to a string? — so an AdminUI-authored config
containing any enum field produced a blob the driver could not parse,
faulting the driver on deploy. Proven end-to-end for S7 and Modbus; latent
for AbCip/AbLegacy/TwinCAT/FOCAS/Galaxy/Historian. Only OpcUaClient was safe
(its factory + probe already carried the converter).
Add JsonStringEnumConverter to all 9 driver-instance pages' _jsonOpts and the
8 missing driver probes' _opts (factories unchanged — already string-via-
ParseEnum; strictly more permissive, also lets pages load hand-seeded
string-enum configs back into the form).
Also fix DriverProbeHandshakeE2eTests.AbCip_Green_AgainstSim to probe a real
sim tag (TestDINT) — the no-tags @raw_cpu_type fallback is rejected by the
ab_server sim with ErrorBadParam (a real ControlLogix returns ErrorNotFound,
which the probe treats as reachable; hardware-gated follow-up).
Tests: reflection guard over all driver pages' _jsonOpts (AdminUI.Tests);
factory round-trip + numeric-form-throws guards for S7 and Modbus.
Found by running the never-before-run FB-9/FB-10 live verifies.
Audit (task #134) found the same Razor literal-binding bug class as the UNS
Filter fix (14b4692): a string-typed component parameter assigned without a
leading @ is a LITERAL, not an expression. Confirmed against the generated
.g.cs (literal "_error" vs TypeCheck<String>(_error)).
- DriverFormShell Error="_error" -> "@_error" on all 9 driver edit pages:
Error received the constant "_error", so the error banner rendered
permanently and the real failure message was never shown.
- DriverBrowseTree SelectedNodeId="_tagName"/"_nodeId" -> "@..." in the
Galaxy and OpcUaClient address pickers: the tree's selected-node highlight
compared against a literal that never matched a real node.
Build clean; generated code now binds all 11 as TypeCheck<String>(field);
AdminUI.Tests 216/216 green.
Deletes the 10 Razor pages superseded by the global /uns tree (Tasks 12–16):
ClusterUns, UnsAreaEdit, UnsLineEdit, ClusterEquipment, EquipmentEdit,
ImportEquipment, ClusterTags, TagEdit, VirtualTags, VirtualTagEdit.
No dangling references found; build is clean.
Persist the canonical AuditOutcome and make structured audit rows visible.
- ConfigAuditLog gains a nullable Outcome column, stored as the AuditOutcome
enum member name (nvarchar(16), mirroring how AdminRole is persisted). The
AuditWriterActor flush now writes Outcome = evt.Outcome.ToString(). Nullable so
legacy rows and the bespoke stored-procedure path (no derived outcome) write
NULL.
- Migration 20260602135350_AddConfigAuditLogOutcome: additive nullable column,
no backfill. Up adds the column, Down drops it. Chains after
20260602112419_CanonicalizeAdminRoles; `dotnet ef migrations
has-pending-model-changes` is clean.
- ClusterAudit visibility fix: the page filtered solely on ClusterId, but the
structured AuditWriterActor path stamps NodeId (ClusterId null), so those rows
were invisible. Extracted ClusterAuditQuery.ForClusterAsync (shared by the page
and tests) which ORs in rows whose NodeId belongs to a node in the cluster —
membership resolved from ClusterNode (NodeId -> ClusterId). SP-path
ClusterId-stamped rows still match.
Tests: ControlPlane 45/45 (adds Outcome persistence + Denied-outcome asserts);
new Configuration ClusterAuditQueryTests 3/3 (both-paths visible, other-cluster
excluded, page-size cap); AdminUI 121/121. Configuration Unit suite is green on a
clean run (a pre-existing timing flake in ResilientConfigReaderTests, untouched
here, occasionally fails under parallel load and passes in isolation).
GalaxyDriverPage deserialized DriverConfig with case-sensitive camelCase opts, but the
persisted/seeded config is PascalCase (the runtime reads it case-insensitively). So all four
nested option records read as null -> FromRecord NRE (HTTP 500) on edit, and the form would
have shown defaults instead of the real config (risking a clobber on save). Fix: add
PropertyNameCaseInsensitive=true (matches the runtime) so real values load, plus null-coalesce
the nested records in FromRecord as defense-in-depth. Regression test asserts the seeded
PascalCase config loads its real values.
The driver/factory/seed use 'GalaxyMxGateway' (legacy 'Galaxy' was retired),
but the AdminUI editor router, GalaxyDriverPage, address picker, identity
dropdown, the Galaxy browser/probe, and DraftValidator still keyed on 'Galaxy'.
Result: the seeded GalaxyMxGateway driver couldn't be edited ('no editor
registered'), UI-created Galaxy drivers wrote a type with no factory, and a
SystemPlatform-bound GalaxyMxGateway driver failed publish validation.
Align all stragglers to GalaxyMxGateway (+ failing-test-first DraftValidator
coverage). ShouldStub's 'Galaxy' legacy safety-net left intact.
Capture the original ModbusTagDefinition as _source in ModbusTagRow and
rewrite ToDefinition() to use 'with {}', so StringByteOrder, ArrayCount,
Deadband, UnitId, and CoalesceProhibited survive a load→edit→save cycle.
- DriverTagPicker shell: modal chrome + per-driver picker body
rendered as ChildContent.
- 9 picker bodies (Modbus/AbCip/AbLegacy/S7/TwinCat/FOCAS/
OpcUaClient/Galaxy/Historian.Wonderware). 5 have computed
builder logic + unit tests; 4 are free-text passthroughs
(live browse for OPC UA + Galaxy is a documented follow-up).
- Each typed driver page gets a "Pick address" button that opens
the modal with the matching body. Picked address surfaces in
the modal footer for manual copy — no JS interop in v1.
- AdminProbeService routes TestDriverConnect through
IAdminOperationsClient with a 65s outer guard (actor side already
clamps to [1,60]).
- Added generic AskAsync<T> to IAdminOperationsClient interface and
AdminOperationsClient impl, delegating straight to the Akka proxy.
- DriverTestConnectButton renders the button + inline result chip,
auto-clears after 30s, disables during in-flight.
- Wired into all 9 typed driver pages directly under the
identity section. Sources timeout from the form's
ProbeTimeoutSeconds; sources config JSON from the form's
current Options (operator can test BEFORE saving).
Live panel subscribed to the /hubs/driverstatus SignalR feed —
renders state chip, last-success age, 5-min error count, last
error message. Auto-reconnect; dimmed when no push arrives for 30s.
Hidden for new instances (nothing deployed yet); shown read-only
on every edit-mode page. Reconnect/Restart buttons land in Phase 8.
- S7DriverPage.FormModel now preserves Tags through Form ↔ Options
translation (was hard-coding Tags = [] on every save, silently
destroying any tag list that operators had configured).
- Add FormModel_RoundTrip tests for OpcUaClient and Historian
mirror classes — both were translating Options ↔ form-model
entirely untested.
- Surface S7 Tags in the round-trip test so this regression
can't reach merge again.
All 9 driver types now have typed pages; DriverEditRouter dispatches
to them directly. Unknown DriverType strings (e.g. legacy rows) render
an explicit error notice instead of falling through to a generic
editor — the failure mode is now visible, not silent.
DriverEditRouter now dispatches every known DriverType to its typed
page. The legacy DriverEdit fallback remains in ResolveComponentType
for forward-compatibility with as-yet-unknown driver types but is no
longer reached for any current driver.
Removes both @page directives from DriverEdit.razor. The picker owns
/drivers/new; the router owns /drivers/{id} and dispatches via
DynamicComponent (currently falls back to DriverEdit for every driver
type — Phase 4 populates the type map one driver at a time).