A thin gateway over the admin-operations cluster singleton so CI/scripts can trigger a
deployment without the Blazor button. Forwards to the same IAdminOperationsClient.
StartDeploymentAsync; mounted on admin-role nodes. Auth is a fixed-time X-Api-Key check
against Security:DeployApiKey (orthogonal to the cookie-only web auth); AllowAnonymous so the
auth fallback doesn't 401 it, self-disabling (503) until the key is set. Outcome->status:
202/200/409/422. Unit tests for the key check + outcome mapping; HTTP E2E (real auth + real
deploy via the 2-node harness). Documented in docs/security.md.
Both bugs surfaced only on split-role deployments (the MAIN cluster's
admin-only nodes), where the AdminUI runs without the driver role.
- Test Connect returned "No probe registered" for every driver: the
IDriverProbe set was registered only under the driver role, but the
admin-operations singleton that consumes it is pinned to admin. Extract
AddOtOpcUaDriverProbes() (idempotent via TryAddEnumerable) and call it
in the hasAdmin path too.
- Live driver-status/alerts/script-log panels showed "SignalR error:
Connection refused": these Blazor Server components opened a HubConnection
to their own hub via the browser's public URL, which server-side code
can't reach behind Traefik (host :9200 -> container :9000). Read the
in-process source directly instead -- DriverStatus via
IDriverStatusSnapshotStore.SnapshotChanged, Alerts/ScriptLog via a new
IInProcessBroadcaster<T>. Fleet status was unaffected (reads DB/ActorSystem).
Adds unit tests for probe registration, the snapshot-store event, and the
broadcaster.
GalaxyDriverPage deserialized DriverConfig with case-sensitive camelCase opts, but the
persisted/seeded config is PascalCase (the runtime reads it case-insensitively). So all four
nested option records read as null -> FromRecord NRE (HTTP 500) on edit, and the form would
have shown defaults instead of the real config (risking a clobber on save). Fix: add
PropertyNameCaseInsensitive=true (matches the runtime) so real values load, plus null-coalesce
the nested records in FromRecord as defense-in-depth. Regression test asserts the seeded
PascalCase config loads its real values.
Capture the original ModbusTagDefinition as _source in ModbusTagRow and
rewrite ToDefinition() to use 'with {}', so StringByteOrder, ArrayCount,
Deadband, UnitId, and CoalesceProhibited survive a load→edit→save cycle.
- DriverTagPicker shell: modal chrome + per-driver picker body
rendered as ChildContent.
- 9 picker bodies (Modbus/AbCip/AbLegacy/S7/TwinCat/FOCAS/
OpcUaClient/Galaxy/Historian.Wonderware). 5 have computed
builder logic + unit tests; 4 are free-text passthroughs
(live browse for OPC UA + Galaxy is a documented follow-up).
- Each typed driver page gets a "Pick address" button that opens
the modal with the matching body. Picked address surfaces in
the modal footer for manual copy — no JS interop in v1.
- S7DriverPage.FormModel now preserves Tags through Form ↔ Options
translation (was hard-coding Tags = [] on every save, silently
destroying any tag list that operators had configured).
- Add FormModel_RoundTrip tests for OpcUaClient and Historian
mirror classes — both were translating Options ↔ form-model
entirely untested.
- Surface S7 Tags in the round-trip test so this regression
can't reach merge again.