I1: Task.WhenAll waits for the slowest device, so concurrency alone still let a device
that accepts TCP and then stalls cost (its tag count x call timeout) per batch. After the
first timeout, transport failure or comms-class status on a device, its remaining tags in
the batch now fail BadCommunicationError immediately, the same as the coalescer's
FailMembers, which now also stops after a failed range. FIXED: tags are still served
from the cache. A malformed address is BadNodeIdUnknown and does not count as a link
failure. Test: a 10-tag stalled device beside a healthy one completes in under 3 call
timeouts with the healthy value Good. The P9 test now also asserts per-client read
counts and that two reads overlapped across devices.
Minors:
- 1: a superseded init releases its table only if it was never published (flag).
- 2: a fixed-tree refusal credits LastSuccessfulRead; a value-path refusal after a comms
fault restores Healthy.
- 5: alarm/fixed/refusal health is reset inside the publish lock, after the generation
check.
- 6: FocasFixedTreeHealthTests wait on served-failure/refusal counters, not wall-clock.
- 8: data-path health writes (reads, coalescer, writes, poll errors, refusals) carry the
generation they started under and are dropped once a lifecycle call has moved on. Each
write is a check-and-set under the lifecycle lock.
Also adds a unit case where 20 vendor records with type 0 and empty messages stay vendor.
Refs #740
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The fixed-tree loop swallowed every failure at Debug and never touched health, so a
driver serving only FIXED: tags (Identity/Axes/Program/Status, the typical FOCAS shape)
read Healthy on /hosts with every node Bad and the #527 watchdog could never fire.
The fixed tree is now a third health path beside the value and alarm paths, combined in
GetHealth (worst state, latest LastSuccessfulRead):
- an answered bootstrap / axis pass clears the device's failure and advances
LastSuccessfulRead;
- a transport failure degrades the driver once the device has been silent past the
same staleness budget that turns its values Bad (from its last answer, or from loop
start when it never answered), with LastSuccessfulRead frozen;
- a CNC refusal (non-OK rc) is not a comms loss: it clears the failure and credits nothing.
Refs #740