Commit Graph

5 Commits

Author SHA1 Message Date
Joseph Doherty 92ba120964 feat(mqtt): MqttDriverForm + MqttDeviceForm — the driver/device config forms P1 omitted
The P1 live gate had to insert MQTT driver config directly via SQL: DriverConfigModal and
DeviceModal both fell through to "No typed config form for driver type Mqtt" with no raw-JSON
fallback, so broker host/port/TLS/credentials were unauthorable from the AdminUI. Task 12 built
the *tag* editor; these are the driver + device surfaces.

MqttDriverForm authors the whole MqttDriverOptions connection surface (host/port/clientId,
TLS + CA pin, credentials, protocol version/clean-session/keep-alive, connect timeout, reconnect
backoffs, mode, maxPayloadBytes, and the Plain sub-object). The Sparkplug sub-object stays P2 —
a marked placeholder mirroring MqttTagConfigEditor's stub, with any existing sparkplug keys
preserved untouched.

The connection is authored on the DRIVER, not the device — unlike Modbus/S7/OpcUaClient and
contrary to what docs/drivers/Mqtt.md said. DriverDeviceConfigMerger merges a device's keys up
only when the driver has exactly ONE device, so a device-authored broker connection vanishes
silently the moment a second device is added. MqttDeviceForm is therefore informational (the
GalaxyDeviceForm shape) and round-trips DeviceConfig verbatim; it flags legacy connection keys
left on a device by a pre-form deployment, because those still win via merge-up.

Serialization goes through the ONE shared MqttJson.Options instance (Task 9's decision), never a
fifth per-form copy — pinned by an assertion that an ordinal-only reader CANNOT bind the emitted
blob, and by extending the fleet-wide DriverPageJsonConverterTests guard to resolve a form's
serializer from an explicit external-instance registry when it has no _jsonOpts field. Dropping
the converter from MqttJson.Options reddens 3 tests and leaves the symmetric round-trip green —
the Task 9 lesson, reproduced.

RawTags is stripped from the emitted blob (the deploy artifact owns it) and unknown top-level
keys survive a load->save. Validation mirrors the driver's own [Range] bounds inline, and
ToOptions() additionally clamps, so an ignored error still cannot persist a
connectTimeoutSeconds:0 driver-brick. A non-blank clientId raises the P1 live-gate warning
inline (fixed ids make redundant pair nodes evict each other while both report Healthy).

AdminUI 761/761 green (was 730), TWAE-clean; Driver.Mqtt 266/266 green.

Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 20:41:48 -04:00
Joseph Doherty 844f93f64f feat(adminui): B2-WP3 driver/device config modals + page-to-form refactor
Extract the 8 typed driver pages into embeddable <Driver>DriverForm bodies
(channel/protocol config) and add per-driver <Driver>DeviceForm bodies
(connection endpoint -> Device.DeviceConfig, v3 endpoint split). New
DriverConfigModal + DeviceModal dispatch by DriverType (DriverTypeNames) for
the /raw tree; Test-connect inside DeviceModal builds the merged Driver+Device
config transiently via DriverDeviceConfigMerger. Routed pages now host the
form bodies and keep working. Round-trip + enum-serialization guard tests for
the Modbus driver form + Modbus device model; retargeted the existing
page-form serialization tests + the _jsonOpts converter guard to the forms.

Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
2026-07-16 03:26:24 -04:00
Joseph Doherty 0b4b2e4cfd refactor(historian-gateway): retire Wonderware historian projects (gateway is sole backend)
The HistorianGateway driver is now the sole historian read/write+alarm backend, so the
Wonderware sidecar projects are dead code. Removes the 5 Wonderware projects (driver,
.Client, .Client.Contracts, + their 2 test projects) from the solution and tree, and fully
retires the vestigial 'Historian.Wonderware' driver type (UI/probe-only; it had no driver
factory): the Host probe registration, the AdminUI driver-config surface (driver page,
tag-config editor/model/validator entry, address picker/builder, driver-type catalog +
dropdown + edit-router entries), and their tests. Prunes the now-unused Wonderware
connection fields (Host/Port/UseTls/ServerCertThumbprint/SharedSecret) from
AlarmHistorianOptions (keeping Enabled + the SQLite store-and-forward knobs) and refreshes
the stale XML docs that named Wonderware as the production backend.

Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
2026-06-26 19:25:21 -04:00
Joseph Doherty a0dccbf8ee test(drivers): tighten driver-page converter guard + clarify S7 numeric case
Code-review follow-ups: the page-coverage test now asserts every *DriverPage
declares a _jsonOpts serializer (so a new page that serialises config a
different way fails the guard, not just converter removal); clarify that 40 ==
(int)S7CpuType.S71500 in the numeric-throws test.
2026-06-19 05:06:43 -04:00
Joseph Doherty 4b14feb373 fix(drivers): serialize driver-config enums as strings in AdminUI pages + probes
AdminUI driver-instance pages serialized enum config fields (S7 CpuType,
Modbus DataType/Region, AbCip PlcFamily, ...) as JSON *numbers* because each
page's _jsonOpts lacked a JsonStringEnumConverter. The driver factories,
however, deserialize into string-typed DTOs (+ lenient ParseEnum) and throw
when binding a JSON number to a string? — so an AdminUI-authored config
containing any enum field produced a blob the driver could not parse,
faulting the driver on deploy. Proven end-to-end for S7 and Modbus; latent
for AbCip/AbLegacy/TwinCAT/FOCAS/Galaxy/Historian. Only OpcUaClient was safe
(its factory + probe already carried the converter).

Add JsonStringEnumConverter to all 9 driver-instance pages' _jsonOpts and the
8 missing driver probes' _opts (factories unchanged — already string-via-
ParseEnum; strictly more permissive, also lets pages load hand-seeded
string-enum configs back into the form).

Also fix DriverProbeHandshakeE2eTests.AbCip_Green_AgainstSim to probe a real
sim tag (TestDINT) — the no-tags @raw_cpu_type fallback is rejected by the
ab_server sim with ErrorBadParam (a real ControlLogix returns ErrorNotFound,
which the probe treats as reachable; hardware-gated follow-up).

Tests: reflection guard over all driver pages' _jsonOpts (AdminUI.Tests);
factory round-trip + numeric-form-throws guards for S7 and Modbus.

Found by running the never-before-run FB-9/FB-10 live verifies.
2026-06-19 04:52:47 -04:00