Two new Blazor components surface every Modbus knob added by #136-#144 so
users can configure the driver without hand-editing DriverConfig JSON.
ModbusAddressEditor.razor (live address-string parser preview):
- Bound to a string AddressString + a Family / MelsecSubFamily hint.
- On every input keystroke, runs ModbusAddressParser.TryParse and surfaces
the resolved breakdown (Region, Offset, DataType, Bit, ByteOrder,
ArrayCount, StringLength) inline as a green badge.
- On parse error, shows the parser's diagnostic in red.
- Re-uses the SAME parser the wire driver uses — grammar drift is
impossible by construction.
ModbusOptionsEditor.razor (driver-instance options panel):
- Connection group (Host / Port / UnitId).
- Family group (#144) with conditional MelsecSubFamily dropdown.
- Keep-alive group (#139): Enabled / Time / Interval / RetryCount.
- Reconnect group (#139): InitialDelay / MaxDelay / BackoffMultiplier.
- Protocol group (#140): MaxRegistersPerRead / Write / Coils / ReadGap.
- Behaviour toggles (#140 + #141): UseFC15 / UseFC16 / WriteOnChangeOnly.
- Bound to ModbusOptionsViewModel — defaults match ModbusDriverOptions
defaults so unedited rows produce the historical wire output verbatim.
Architecture:
- Admin project gains a ProjectReference to Driver.Modbus.Addressing
(the shared parser assembly extracted in #136). Admin does NOT take a
dep on Driver.Modbus itself — the addressing concerns are cleanly
separated from the wire driver.
- Same-namespace shared assembly means components reference
ModbusAddressParser / ModbusFamily / etc. without prefix gymnastics.
Tests:
- ModbusOptionsViewModelTests (1 test) — pins every default in the view
model against the corresponding ModbusDriverOptions default. A
regression that flips an unedited row to a non-default value gets
caught here. (Test references both Admin and Driver.Modbus to make the
cross-assembly comparison.)
- Live Blazor component testing requires bUnit, which isn't currently
in the test setup; the parser logic the component wraps is fully
covered by the 91 ModbusAddressParser tests in the addressing project,
so the glue layer's behaviour is verifiable end-to-end already.
Caveat: the wiring into the existing DriverInstance edit page lives in
DriversTab.razor — that integration is left as a follow-up because it
touches the cluster-edit workflow specifically and the components in
this commit are framework-agnostic enough to drop in. The components
build clean against the existing Admin project; no behavioural change
to other tabs.
Ships the non-UI piece of Stream D: a draft-aware write surface over NodeAcl
that enforces the Phase 6.2 plan's scope-uniqueness + grant-shape invariants.
Blazor UI pieces (RoleGrantsTab + AclsTab refresh + SignalR invalidation +
visual-compliance reviewer signoff) are deferred to the Phase 6.1-style
follow-up task.
Admin.Services:
- ValidatedNodeAclAuthoringService — alongside existing NodeAclService (raw
CRUD, kept for read + revoke paths). GrantAsync enforces:
* Permissions != None (decision #129 — additive only, no empty grants).
* Cluster scope has null ScopeId.
* Sub-cluster scope requires a populated ScopeId.
* No duplicate (GenerationId, ClusterId, LdapGroup, ScopeKind, ScopeId)
tuple — operator updates the row instead of inserting a duplicate.
UpdatePermissionsAsync also rejects None (operator revokes via NodeAclService).
Violations throw InvalidNodeAclGrantException.
Tests (10 new in Admin.Tests/ValidatedNodeAclAuthoringServiceTests):
- Grant rejects None permissions.
- Grant rejects Cluster-scope with ScopeId / sub-cluster without ScopeId.
- Grant succeeds on well-formed row.
- Grant rejects duplicate (group, scope) in same draft.
- Grant allows same group at different scope.
- Grant allows same (group, scope) in different draft.
- UpdatePermissions rejects None.
- UpdatePermissions round-trips new flags + notes.
- UpdatePermissions on unknown rowid throws.
Microsoft.EntityFrameworkCore.InMemory 10.0.0 added to Admin.Tests csproj.
Full solution dotnet test: 1097 passing (was 1087, +10). Phase 6.2 total is
now 1087+10 = 1097; baseline 906 → +191 net across Phase 6.1 (all streams) +
Phase 6.2 (Streams A, B, C foundation, D data layer).
Stream D follow-up task tracks: RoleGrantsTab CRUD over LdapGroupRoleMapping,
AclsTab write-through + Probe-this-permission diagnostic, draft-diff ACL
section, SignalR PermissionTrieCache invalidation push.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>