Commit Graph

15 Commits

Author SHA1 Message Date
Joseph Doherty 8d3dc32148 feat(modbus): String + BitInRegister array decode + equipment-tag arrayLength
- DecodeRegisterArray: add String and BitInRegister cases replacing the
  default:throw; each element decoded by reusing DecodeRegister on its
  contiguous register slice → string[] / bool[]
- ModbusEquipmentTagParser.TryParse: read optional arrayLength key from
  TagConfig JSON and thread it into ModbusTagDefinition.ArrayCount
  (null when absent or zero, preserving scalar behaviour)
- ModbusArrayTests: 8 new tests covering the two decode cases and the
  equipment-tag parser/resolver path; 285/285 green
2026-06-16 21:51:55 -04:00
Joseph Doherty 8b4675b1a5 fix(adminui): canonicalize Modbus driver-type string on "Modbus" (was ModbusTcp) 2026-06-16 19:39:41 -04:00
Joseph Doherty 9b909002be feat(probe): Modbus Test-Connect does a real FC03 handshake
Replace the bare TCP-connect probe in ModbusDriverProbe with a two-phase
check: TCP connect via ModbusTcpTransport (keeps the same SocketException /
timeout / generic error paths and messages), then a one-shot FC03 Read
Holding Registers (qty 1 @ addr 0). A normal response → Ok=true "Modbus
FC03 OK"; a Modbus exception PDU → Ok=true "Modbus FC03 OK (device
returned exception PDU)"; any other failure after TCP succeeds → Ok=false
"Reachable at host:port but Modbus FC03 handshake failed: …".

Add ModbusDriverProbeTests (6 tests) covering invalid JSON, missing
host/port, closed port, TCP-accept-then-close, canned MBAP happy path,
and Modbus exception PDU path. All 277 Modbus tests green.
2026-06-16 06:36:48 -04:00
Joseph Doherty bd8fee610b fix(modbus): surface Int64/UInt64 node DataType (Driver.Modbus-007)
Make MapDataType internal, split the combined Int64/UInt64 arm to return
DriverDataType.Int64 and DriverDataType.UInt64 respectively, and remove
the now-stale Driver.Modbus-007 caveat doc block and inline comment.
Add a Theory covering both cases; full suite 271/271 green.
2026-06-16 05:23:47 -04:00
Joseph Doherty 232c557985 feat(modbus): resolve equipment-tag refs (read + write) via EquipmentTagRefResolver 2026-06-13 11:18:00 -04:00
Joseph Doherty 57355405a6 chore(security): drop dead audit suppressions; patch OpenTelemetry + Tmds.DBus CVEs
All five suppressed advisories are now resolved at baseline/resolved versions,
so every NuGetAuditSuppress is removed repo-wide:
- System.Security.Cryptography.Xml (GHSA-37gx-xxp4-5rgx / GHSA-w3x6-4m5h-cxqf)
  -> fixed by the .NET 10 baseline (10.0.6)
- OPCFoundation Opc.Ua.Core (GHSA-h958-fxgg-g7w3) -> fixed at resolved 1.5.378.106

Two were still live and are now patched via direct security pins:
- OpenTelemetry.Api 1.9.0 -> 1.15.3 (GHSA-g94r-2vxg-569j) pinned in Cluster;
  Runtime/ControlPlane/AdminUI + tests inherit via project reference
- Tmds.DBus.Protocol 0.20.0 -> 0.21.3 (GHSA-xrw6-gwf8-vvr9) pinned in Client.UI

Also correct the Historian sidecar runtime comments (x86 -> x64, matching the
csproj PlatformTarget). Solution audit: 0 vulnerable packages; full build clean.
2026-06-12 09:03:42 -04:00
Joseph Doherty 54f0dbddb9 fix(drivers): align probe DriverType strings with AdminUI keys
ModbusDriverProbe.DriverType was "Modbus" but the AdminUI's
ModbusDriverPage persists DriverInstance.DriverType = "ModbusTcp".
GalaxyDriverProbe used the runtime DriverTypeName constant
("GalaxyMxGateway") but the AdminUI saves "Galaxy". The probe DI
lookup is case-insensitive but not name-insensitive, so Test
Connect would fail to find a probe for these two drivers.
2026-05-28 10:55:15 -04:00
Joseph Doherty c19d124e89 feat(drivers): TCP-connect IDriverProbe for all 9 driver types
Cheap-and-fast probe: open TCP socket to the configured endpoint,
close immediately. Surfaces SocketError on failure, latency on
success, "timed out" on caller cancel. Sufficient for the AdminUI
Test Connect "can we reach the host?" question. Richer protocol-
level probes (OPC UA session open, FOCAS handshake, gRPC ping)
are a documented follow-up. Each probe registered as
AddSingleton<IDriverProbe, X> in DriverFactoryBootstrap so they
flow through DI into AdminOperationsActor.

Historian.Wonderware returns a clean "TCP probe not applicable"
result because it communicates over a Windows named pipe, not TCP.
Also adds OpcUaClient + Historian.Wonderware.Client project
references to Host.csproj (both were missing from the driver
ItemGroup).
2026-05-28 10:53:42 -04:00
Joseph Doherty 5058a56645 refactor(driver-modbus): extract ModbusDriverOptions to .Contracts
Move ModbusDriverOptions (and companion option types) to a new
Driver.Modbus.Contracts sibling project. The contracts project
references only Driver.Modbus.Addressing (itself zero-dep and
Admin-safe) because ModbusDriverOptions.Probe/Family/Region
properties use enum types that live there.

Drop 'using ZB.MOM.WW.OtOpcUa.Core.Abstractions' and replace
<see cref="IHostConnectivityProbe"/> with <c>IHostConnectivityProbe</c>
per the approved decision — the using was doc-comment-only.

The runtime Driver.Modbus project gains a ProjectReference back to
.Contracts; the .slnx is updated accordingly.
2026-05-28 08:50:17 -04:00
Joseph Doherty 64e3fbe035 docs: backfill XML documentation across 756 files
v2-ci / build (push) Failing after 1m43s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public
members surfaced by commentchecker — resolves 5,847 of 5,869 issues
(99.6%) across three /fixdocs passes.
2026-05-28 08:10:17 -04:00
Joseph Doherty a6ae4e22d1 fix(status-codes): correct BadDeviceFailure from 0x80550000 to 0x808B0000
Driver.Cli.Common-007 + Driver.Cli.Common-008 resolution.

Driver.Cli.Common-007 (High, Correctness):
  0x80550000 is the canonical OPC UA spec value for BadSecurityPolicyRejected,
  not BadDeviceFailure. The correct spec value for BadDeviceFailure is
  0x808B0000 (verified against OPC Foundation Opc.Ua.StatusCodes;
  corroborated locally by Driver.Galaxy.Runtime.StatusCodeMap and both
  Wonderware historian quality mappers which all hand-pin the correct
  value).

  The bug was duplicated across six driver modules:
    - FocasStatusMapper.BadDeviceFailure
    - AbCipStatusMapper.BadDeviceFailure
    - AbLegacyStatusMapper.BadDeviceFailure
    - TwinCATStatusMapper.BadDeviceFailure
    - ModbusDriver.StatusBadDeviceFailure
    - S7Driver.StatusBadDeviceFailure
  Plus the SnapshotFormatter shortlist that named 0x80550000 as
  BadDeviceFailure, and three downstream Modbus tests that asserted
  against the wrong value (so CI was blind).

  This commit fixes all six native-mapper constants, the formatter
  shortlist, and the three Modbus tests in one pass. Added a regression
  guard to FormatStatus_does_not_apply_pre_fix_wrong_names that pins
  0x80550000 never renders as BadDeviceFailure (mirroring the existing
  -001 wrong-name guards).

  Behavior change: OPC UA clients consuming the native drivers now see
  the canonical BadDeviceFailure (0x808B0000) on device-fault paths
  instead of the misnamed BadSecurityPolicyRejected (0x80550000). Wire-
  level status semantics now match operator-facing CLI labels.

Driver.Cli.Common-008 (Low, Testing):
  Deleted the redundant FormatStatus_names_native_driver_emitted_codes
  Theory — its five InlineData rows were already covered by the
  well-known Theory in the same commit (5a9c459), and used a weaker
  ShouldContain vs the well-known Theory's ShouldBe (exact match).

Verification:
  - Driver.Cli.Common.Tests: 43/43 pass (was 48 after the -008 deletion).
  - Driver.Modbus.Tests: 263/263 pass.
  - Driver.AbCip.Tests: 262/262.
  - Driver.AbLegacy.Tests: 157/157.
  - Driver.FOCAS.Tests: 178/178.
  - Driver.S7.Tests: 112/112.
  - Driver.TwinCAT.Tests: 131/131.
  Total: 1146 tests across the affected modules, all green.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-23 17:14:28 -04:00
Joseph Doherty d5322b0f9a fix(driver-modbus): resolve Low code-review findings (Driver.Modbus-003,007,008,009,010,011,012)
- Driver.Modbus-003: route every _health access through ReadHealth /
  WriteHealth helpers backed by Volatile.Read / Volatile.Write so a
  burst of concurrent ReadAsync callers always sees a complete snapshot.
- Driver.Modbus-007: promoted the Int64 / UInt64 → Int32 surfacing
  caveat to a full <remarks> block; rewrote DisableFC23's doc to flag it
  as reserved / no-op.
- Driver.Modbus-008: deleted stale duplicate doc, rewrote the
  prohibition-block summaries to credit the shipped re-probe loop, and
  removed the unused 'status' local in the ModbusException catch arm.
- Driver.Modbus-009: bind-time validation rejects StringLength < 1 for
  String tags; ModbusTcpTransport clamps keep-alive intervals to whole
  seconds (>=1).
- Driver.Modbus-010: documented WriteOnChangeOnly's cache-invalidation
  policy (reads-only) and the write-only-tag caveat.
- Driver.Modbus-011: collected the scattered instance fields into a
  single contiguous block at the top of ModbusDriver.
- Driver.Modbus-012: covered the previously-uncovered Reinitialize
  state-hygiene, malformed/truncated/empty-bitmap response, and
  DisposeAsync teardown paths.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-23 08:17:51 -04:00
Joseph Doherty c5f2d91bcb fix(driver-modbus): resolve Medium code-review finding (Driver.Modbus-002)
Clear _tagsByName, _lastPublishedByRef, and _lastWrittenByRef in ShutdownAsync
(via the new shared TeardownAsync helper) so a ReinitializeAsync cycle starts
from a clean state, consistent with the existing _autoProhibited.Clear().

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-22 09:48:09 -04:00
Joseph Doherty 532b961cf2 fix(driver-modbus): resolve High code-review finding (Driver.Modbus-001)
_lastPublishedByRef was a plain Dictionary<string, object> mutated inside
ShouldPublish, which runs on the PollGroupEngine onChange callback. The engine
runs one background Task per subscription, so a driver with two or more
subscriptions invokes ShouldPublish concurrently on separate threads. Concurrent
TryGetValue/indexer writes on a non-thread-safe Dictionary can corrupt internal
state, drop entries, or throw, crashing the poll loop.

Switch _lastPublishedByRef to ConcurrentDictionary<string, object>; its
TryGetValue and indexer-set operations are individually thread-safe, so the
deadband cache is now correct under concurrent multi-subscription publishing,
consistent with the lock-guarded sibling cache _lastWrittenByRef.

Add an xUnit + Shouldly regression test that runs 24 deadband-configured
single-tag subscriptions concurrently and asserts the poll loop survives without
faulting.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-22 06:59:39 -04:00
Joseph Doherty a25593a9c6 chore: organize solution into module folders (Core/Server/Drivers/Client/Tooling)
Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.

- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
  the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
  mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
  integration, install).

Build green (0 errors); unit tests pass. Docs left for a separate pass.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-17 01:55:28 -04:00