DiscoverAsync now unconditionally emits SecurityClassification.ViewOnly
for every user-authored FOCAS tag. Previously the SecurityClass was
tag.Writable ? Operate : ViewOnly, but WireFocasClient.WriteAsync always
returns BadNotWritable — advertising Operate misleads OPC UA clients
and the DriverNodeManager ACL layer into granting write permission on
nodes that can never be written.
Updated FocasCapabilityTests.DiscoverAsync_emits_pre_declared_tags to
assert ViewOnly for the writable-by-config tag so it matches the
corrected behaviour.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.
- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
integration, install).
Build green (0 errors); unit tests pass. Docs left for a separate pass.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>