Commit Graph

2 Commits

Author SHA1 Message Date
Joseph Doherty
9dd5e4e745 Phase 6.1 Stream C — health endpoints on :4841 + LogContextEnricher + Serilog JSON sink + CapabilityInvoker enrichment
Closes Stream C per docs/v2/implementation/phase-6-1-resilience-and-observability.md.

Core.Observability (new namespace):
- DriverHealthReport — pure-function aggregation over DriverHealthSnapshot list.
  Empty fleet = Healthy. Any Faulted = Faulted. Any Unknown/Initializing (no
  Faulted) = NotReady. Any Degraded or Reconnecting (no Faulted, no NotReady)
  = Degraded. Else Healthy. HttpStatus(verdict) maps to the Stream C.1 state
  matrix: Healthy/Degraded → 200, NotReady/Faulted → 503.
- LogContextEnricher — Serilog LogContext wrapper. Push(id, type, capability,
  correlationId) returns an IDisposable scope; inner log calls carry
  DriverInstanceId / DriverType / CapabilityName / CorrelationId structured
  properties automatically. NewCorrelationId = 12-hex-char GUID slice for
  cases where no OPC UA RequestHeader.RequestHandle is in flight.

CapabilityInvoker — now threads LogContextEnricher around every ExecuteAsync /
ExecuteWriteAsync call site. OtOpcUaServer passes driver.DriverType through
so logs correlate to the driver type too. Every capability call emits
structured fields per the Stream C.4 compliance check.

Server.Observability:
- HealthEndpointsHost — standalone HttpListener on http://localhost:4841/
  (loopback avoids Windows URL-ACL elevation; remote probing via reverse
  proxy or explicit netsh urlacl grant). Routes:
    /healthz → 200 when (configDbReachable OR usingStaleConfig); 503 otherwise.
      Body: status, uptimeSeconds, configDbReachable, usingStaleConfig.
    /readyz  → DriverHealthReport.Aggregate + HttpStatus mapping.
      Body: verdict, drivers[], degradedDrivers[], uptimeSeconds.
    anything else → 404.
  Disposal cooperative with the HttpListener shutdown.
- OpcUaApplicationHost starts the health host after the OPC UA server comes up
  and disposes it on shutdown. New OpcUaServerOptions knobs:
  HealthEndpointsEnabled (default true), HealthEndpointsPrefix (default
  http://localhost:4841/).

Program.cs:
- Serilog pipeline adds Enrich.FromLogContext + opt-in JSON file sink via
  `Serilog:WriteJson = true` appsetting. Uses Serilog.Formatting.Compact's
  CompactJsonFormatter (one JSON object per line — SIEMs like Splunk,
  Datadog, Graylog ingest without a regex parser).

Server.Tests:
- Existing 3 OpcUaApplicationHost integration tests now set
  HealthEndpointsEnabled=false to avoid port :4841 collisions under parallel
  execution.
- New HealthEndpointsHostTests (9): /healthz healthy empty fleet; stale-config
  returns 200 with flag; unreachable+no-cache returns 503; /readyz empty/
  Healthy/Faulted/Degraded/Initializing drivers return correct status and
  bodies; unknown path → 404. Uses ephemeral ports via Interlocked counter.

Core.Tests:
- DriverHealthReportTests (8): empty fleet, all-healthy, any-Faulted trumps,
  any-NotReady without Faulted, Degraded without Faulted/NotReady, HttpStatus
  per-verdict theory.
- LogContextEnricherTests (8): all 4 properties attach; scope disposes cleanly;
  NewCorrelationId shape; null/whitespace driverInstanceId throws.
- CapabilityInvokerEnrichmentTests (2): inner logs carry structured
  properties; no context leak outside the call site.

Full solution dotnet test: 1016 passing (baseline 906, +110 for Phase 6.1 so
far across Streams A+B+C). Pre-existing Client.CLI Subscribe flake unchanged.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 08:15:44 -04:00
Joseph Doherty
2f00c74bbb Phase 3 PR 32 — Multi-driver integration test. Closes LMX follow-up #6 with Server.Tests/MultipleDriverInstancesIntegrationTests.cs: registers two StubDriver instances (alpha + beta) with distinct DriverInstanceIds on one DriverHost, boots the full OpcUaApplicationHost, and exercises three behaviors end-to-end via a real OPC UA client session. (1) Each driver's namespace URI resolves to a distinct index in the client's NamespaceUris (alpha → urn:OtOpcUa:alpha, beta → urn:OtOpcUa:beta) — proves DriverNodeManager's namespaceUris-per-driver base-ctor wiring actually lands two separate INodeManager registrations. (2) Browsing one subtree returns only that driver's folder; the other driver's folder does NOT leak into the wrong subtree. This is the test that catches a cross-driver routing regression the v1 single-driver code path couldn't surface — if a future refactor flattens both drivers into a shared namespace, the 'shouldNotContain' assertion fails cleanly. (3) Reads route to the owning driver by namespace — alpha's ReadAsync returns 42 while beta's returns 99; a misroute would surface as 99 showing up on an alpha node id or vice versa. StubDriver is parameterized on (DriverInstanceId, folderName, readValue) so the same class constructs both instances without copy-paste.
No production code changes — pure additive test. Server.Tests Integration: 3 new tests pass; existing OpcUaServerIntegrationTests stays green (single-driver case still exercised there). Full Server.Tests Unit still 43 / 0. Deferred: multi-driver alarm-event case (two drivers each raising a GalaxyAlarmEvent, assert each condition lands on its owning instance's condition node) — needs a stub IAlarmSource and is worth its own focused PR.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-18 15:29:49 -04:00