73132b7d78da002b37f08fa0a94cebfe88c07034
5 Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
a157b27628 |
fix(install): swap waits for the host process to exit before moving the folder (#908)
v2-ci / unit-tests (push) Has been cancelled
On QA (
|
||
|
|
0c19f26c81 |
fix(install): cut the swap's stopped window to the swapped-in folder (#905)
v2-ci / unit-tests (push) Has been cancelled
Root cause: the protected-DACL coverage scan, not the ACL writes. Both -Reapply and -Verify walked every denied folder (all of E:\ApiInstall on vd03, nested roots again) with Get-ChildItem -Recurse + Get-Acl per item + a pipeline per item for -Skip, about 3.4 ms an item on PS 5.1, all while the service was stopped. An unchanged deny is read, not rewritten; the re-applied install-folder deny propagates over ~1,400 files in 0.5 s. - Find-OtOpcUaDenyCoverageGap: .NET enumeration, -Skip folders pruned, DACL-only GetAccessControl(Access) (about 0.15 ms an item); reparse points not followed. - Get-OtOpcUaCoverageWalkRoots: each denied folder walked once (outermost only). - Install-ScriptWorkerIsolation.ps1 -Scope All|InstallRoot|Outside (with -Reapply, -Verify, -PlanOnly). InstallRoot = the folder ACEs a swap drops; Outside = the rest, including the firewall rule (its query costs 3-5 s; its exe path does not change). The two partition the plan. Prints the scan time. - Invoke-OtOpcUaInstallSwap.ps1: -Reapply/-Verify -Scope Outside before the stop (a failure stops before anything moves), -Scope InstallRoot inside the window; preflight checks the candidate carries the worker exe; prints the stopped window and its parts. -NoStart, -NoCarry and the pre-#901 refusal unchanged. windev, vd03-like tree (17,851 items): stopped window 153.1 s -> 6.0 s (PS 5.1), 101.6 s -> 6.2 s (PS 7); the Outside part takes ~23 s with the old build serving. Dry-run harness 101 -> 123 passed; Windows test 72 passed on PS 5.1 and PS 7. Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi |
||
|
|
2cb8a2c317 |
fix(install): worker isolation survives a folder swap: recorded settings, -Reapply, -Verify, swap script (#901)
v2-ci / unit-tests (push) Has been cancelled
An upgrade that swaps the install folder dropped the explicit ScriptWorker isolation ACEs on script-worker\, the install folder and a copied-back pki\ (vd03 2026-11-13). Re-applying needed the operator to repeat the arguments. - Install-ScriptWorkerIsolation.ps1 records its effective settings (InstallRoot, HostServiceAccount, PeCacheDir, HostServiceName, ConfigureHostService) beside DenyPaths under ...\Services\OtOpcUaScriptWorker\Parameters (new plan step SettingsRecord) and locks that key to SYSTEM + Administrators (protected DACL; no secrets recorded). - -Reapply: re-apply from the record, no arguments; prints a summary line (changed/unchanged). - -Verify: check only, [ok]/[MISSING] per step, exit 1 when anything is missing. -Uninstall also works from the record. A node isolated by a pre-#901 installer (DenyPaths only) must run the full-argument install once; both modes say so. - Invoke-OtOpcUaInstallSwap.ps1: preflight -> stop -> move live/candidate -> carry appsettings/pki/logs -> -Reapply -> -Verify -> start; a failed -Verify leaves the service stopped. Also the rollback (-NoCarry). - Tests: dry-run harness 101/101 (record + argument rules; record-key SDDL mutation turns 2 red). The Windows test adds swap -> Verify fails (exactly the 3 lost ACEs) -> Reapply (3 changed) -> Verify ok -> Reapply 12/12 unchanged, PE-cache and firewall negative controls, the swap script, and the pre-#901 refusal; 52/52 on windev under 5.1 and 7, with a scratch local host account and with SYSTEM. Evidence: scripts/validation/opcua-windows-service/evidence/2026-11-13-windev-901-reapply-verify. - Docs: ServiceHosting isolation section; vd03 pack (swap step, rollback, post-deploy gate, one-time full-argument run), the 2026-11-13 vd03 record, and the QA pack (QA swap preceded the isolation install; ACLs checked intact over SMB on vq03/vq04 2026-11-13; next-deploy procedure). Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi |
||
|
|
f75ee7d089 |
fix(scripting): ScriptWorker isolation denies the worker every sensitive sibling, not just app\ (#890)
v2-ci / unit-tests (push) Waiting to run
The installer denied NT SERVICE\OtOpcUaScriptWorker only on -InstallRoot. On the wonder layout the node's keys and secrets sit beside it (E:\ApiInstall\OtOpcUa\pki with the application certificate's private key, data\ with secrets.db and LocalDb), inheriting BUILTIN\Users:RX. Users is a restricting SID of the worker token, so a worker could read them. - Install-ScriptWorkerIsolation.ps1 -DenyPaths <dir>,...: each folder gets the same inherited deny as InstallRoot (new SensitiveDirDeny steps). Refuses drive/share roots, script-worker\ and the PE cache; folders must exist; a comma/semicolon string works for powershell -File. - The deny is read AND write (0xD0157: ReadData, WriteData, AppendData, WriteEA, DeleteChild, WriteAttributes, Delete, WRITE_DAC, WRITE_OWNER). Traverse/Execute, ReadAttributes, ReadControl and Synchronize stay so the loader still reaches script-worker\. The write half stops a worker planting a cert in pki\trusted\certs where a data drive lets Users create files in subfolders. - The list is recorded under the anchor service's key (Parameters\DenyPaths, step DenyPathRecord): a re-run removes the deny from folders dropped from the list, -Uninstall removes every recorded one without repeating -DenyPaths. -WhatIf/-PlanOnly print every step. - After an apply, WARN for each protected-DACL item under a denied folder that the inherited deny cannot reach; without -DenyPaths, WARN for pki/data/logs/backup/config/secrets siblings of InstallRoot. Tests: - Dry-run harness 46 -> 86 assertions (QA layout plan, mask bits, refusals, stale removal, record-driven rollback, host account never denied). Mutations (no sibling deny, deny->allow, mask back to ReadData, no stale removal, rollback ignoring the record, script-worker not refused) each turn it red. - Test-ScriptWorkerIsolation.Windows.ps1 (Windows PowerShell 5.1, windev): 34/34, incl. -DenyPaths apply, 11/11 unchanged re-apply, shorter-list re-apply, uninstall from the record, second uninstall unchanged. - New InstallerLayoutIsolationTests (OTOPCUA_ISOLATION_INSTALLER_E2E=1, elevated Windows): a scratch wonder layout under the real restricted worker token. Before install and after uninstall the token reads pki/data/ logs/backup/appsettings and plants a trust-list file; installed it can do neither, still reads script-worker\, a real worker launched from the layout runs a script, and the host still reads everything. Mutating the -DenyPaths denies to a no-op mask turns it red on pki\own\private\otopcua.pfx (reproduces #890). QA vq03/vq04 are NOT re-applied; the command is in docs/deploy/qa-upgrade-b8b4c18f-to-fea7de0a.md. Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi |
||
|
|
88e53f7f84 |
fix(install): Install-ScriptWorkerIsolation.ps1 works on PowerShell 7 and 5.1, -Uninstall included (#883)
First real run of the #780 installer (windev, #800 gate) failed on both hosts and its rollback failed too: - PowerShell 7: DirectoryInfo.GetAccessControl/SetAccessControl do not exist on .NET. Use Get-Acl / Set-Acl. - Windows PowerShell 5.1: an if-expression unrolled the wanted ACE to a scalar ($null on -Remove), so .Count threw under StrictMode. Wrap it in @(...). - Found on the re-run: an apply from 5.1 was not idempotent. 5.1 passes the literal quotes in sc.exe binPath= with legacy quoting, so the anchor path was stored unquoted and AnchorService reported 'changed' on every run. sc create/config now runs through Invoke-OtOpcUaSc with an explicit command line, identical on both hosts. Adds scripts/install/tests/Test-ScriptWorkerIsolation.Windows.ps1: a Windows-executed dry run -> apply -> re-apply -> uninstall -> uninstall test (scratch names, stand-in host service) for either host. The plan-only harness cannot see these. Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi |