- Driver.FOCAS.Cli-001: WriteCommand.ParseValue now wraps numeric
FormatException / OverflowException as CliFx CommandException with
the offending value.
- Driver.FOCAS.Cli-002: SubscribeCommand's OnDataChange handler and the
banner both take a writeLock so notification-callback and main-thread
writes can't interleave; handler exceptions are warn-and-swallow.
- Driver.FOCAS.Cli-003: FocasCommandBase.ValidateOptions rejects
--cnc-port outside 1..65535, non-positive --timeout-ms, and
non-positive --interval-ms; ExecuteAsync calls it first.
- Driver.FOCAS.Cli-004: 'await using var driver' is the sole driver
disposal path; dropped the redundant explicit await ShutdownAsync.
- Driver.FOCAS.Cli-005 (Deferred): the fix lives in
Driver.Cli.Common.SnapshotFormatter — explicitly naming the
status-code shortlist there benefits every driver CLI. Left as a
Driver.Cli.Common follow-up.
- Registered the new tests/Drivers/Cli/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli.Tests
project in ZB.MOM.WW.OtOpcUa.slnx.