Reshapes the placeholder buffered-counter actor into a thin fire-and-forget
bridge over the existing IAlarmHistorianSink contract. Default sink is
NullAlarmHistorianSink; production deployments override the DI binding to
SqliteStoreAndForwardSink wrapping WonderwareHistorianClient (the v1
components in src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Historian.Wonderware*
are reused verbatim — actor is just a mailbox-friendly entry point).
- HistorianAdapterActor.Props(IAlarmHistorianSink?) — null defaults to NullAlarmHistorianSink
- Receive<AlarmHistorianEvent>: fire-and-forget sink.EnqueueAsync
- Receive<GetStatus>: returns sink.GetStatus() (queue depth + drain state)
- ServiceCollectionExtensions.AddOtOpcUaRuntime registers the default sink
- WithOtOpcUaRuntimeActors spawns the actor + registers HistorianAdapterActorKey
- Program.cs calls AddOtOpcUaRuntime when hasDriver
Tests: 2 new (forward-to-sink + GetStatus). Runtime suite 17 → 18.
Mirrors WithOtOpcUaControlPlaneSingletons for the driver role. Spawns
DriverHostActor + DbHealthProbeActor on the host's ActorSystem and
registers both under marker keys. Host's Program.cs now calls it when
the node carries the driver role, so driver-only and admin+driver
deployments both auto-bootstrap the per-node actors.
Integration test covers the registration round-trip via Microsoft.Extensions.Hosting
+ Akka.Hosting AddAkka.