Owner decisions §14 #5/#6 as built (design §12.5):
- Scripting:Worker:Identity (default unset, Windows only, fail-closed validation): each worker
starts under a restricted token derived from the host's. Every privilege but SeChangeNotify is
removed; the restricting SIDs are NT SERVICE\OtOpcUaScriptWorker's SID + Everyone + Users +
RESTRICTED; the token and default DACLs are host + SYSTEM + identity + RESTRICTED. The worker
is created suspended, put in its Job Object before it runs, inherits only its stdio pipes, gets
an ACL'd work dir as TEMP, and runs with DOTNET_EnableDiagnostics=0. The identity is granted on
the host's window station and desktop, because USER32 init made coreclr.dll fail with
ERROR_DLL_INIT_FAILED on windev. The logon SID is not used because the host's process DACL
gives it PROCESS_VM_READ.
- The worker pipe on Windows always has an explicit protected DACL: host account + identity
only. There is no owner ACE, so an elevated host's Administrators gets no access.
- The worker treats access denied on its parent-pid poll as alive; the Job Object covers that case.
- scripts/install/Install-ScriptWorkerIsolation.ps1 + ScriptWorkerIsolation.psm1 are idempotent
and support -WhatIf, -Uninstall and -PlanOnly. They create the disabled anchor service, the
PeCacheDir ACL (protected, no Users, key and markers host-only, pe\ Modify for the identity),
read+execute on script-worker\, a ReadData deny on the install root, the outbound firewall
block on the worker exe, and optionally the host-service env.
- Tests: the dry-run harness scripts/install/tests/Test-ScriptWorkerIsolation.ps1 (46
assertions, mutation-checked); ScriptWorkerIdentityTests; WorkerIsolationTests, which cover
the pipe ACL, token access and a real restricted worker running a script, all green on windev.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
v2-integration.yml runs the Sql, Historian.SqlServer, Historian.QuestDb and OpcUaClient
integration projects against throwaway SQL Server/PostgreSQL/QuestDB/opc-plc containers
started by scripts/ci/integration-fixtures.sh, with a MIN_EXECUTED=440 floor. v2-e2e.yml is
manual/weekly, probes the shared fleet and skips cleanly when unreachable. v2-ci.yml is
functionally unchanged. Unverified on a hosted runner until first run.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Run 959 (job 3552) was silent from 13:39 for 3h12m and was failed by the server
reaper with no cause. Pre-#707 runs 935/938/941/942/947/959 all ended at 189-193 min;
no run since 76bdca90 exceeds 82 min (healthy ~53). Adds timeout-minutes 120 and
blame-hang (20m, no dump) to the whole-solution test step.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Review round 1 on the golden frames:
- Re-captured logix-read-dint-array16 (element i = ((i+1)<<24)|(i+1)) and
logix-read-bool (= 1) so neither decode oracle is all zeros. ab_server rejects
libplctag's own BOOL write with CIP 0x03 (two data bytes for a one-byte BOOL),
so the BOOL is seeded by a raw UCMM Write Tag (client seed-bool).
- Committed the capture client as scripts/ab-capture/client (outside the slnx,
CPM off, libplctag 1.5.2 pinned); capture.sh gains a `client` subcommand.
- README documents simulator-only behaviour: zeroed reply sender context, STRING
typed D0 00 instead of A0 02 + handle, and the BOOL write refusal.
- capture.sh no longer claims UnregisterSession reaches the wire (session ends in RST).
- CaptureFileTests also check the CPF walk ends at the frame end and that every
reply service is its request service | 0x80.
17 .hex fixtures captured from libplctag 1.5.2 (native 2.6.0) against
otopcua-ab-server:libplctag-release, plus the CaptureFile loader, its
length/alternation tests, and the re-runnable scripts/ab-capture/capture.sh.
Observed and recorded in Captures/README.md "Routing observed":
- Micro800 is NOT UCMM under libplctag 2.6.0: it opens a Large Forward Open
(path 20 02 24 01) and reads connected; use_connected_msg=0 is ignored.
- SLC500/MicroLogix/PLC-5 send Execute PCCC 0x4B unconnected and unwrapped;
a configured path=1,0 never reaches the wire.
- Only Large FO 0x5B was observed; no 0x54 fallback occurred.
- LogixPccc is unreachable against ab_server (CIP 0x08); no fixture committed.
The proxyOptions local in WithOtOpcUaControlPlaneSingletons was already unused on master
(pre-existing dead code, not orphaned by the deletion commit — every registration passes
singletonOptions); removed while the file is open. The phase-6-1 compliance script still
Assert-Deferred'd the FleetStatusHub /hosts follow-up — an item that is now deleted, not
deferred — replaced with a retirement comment.