5ed26d2ec651e6c78b3547b5c49123dc0219c16e
3 Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
4b0664bd55 |
FOCAS — retire Tier-C split, inline managed wire client, make read-only
Migration closes the FOCAS Tier-C architecture. OtOpcUa previously had
`Driver.FOCAS.Host` (NSSM-wrapped Windows service loading Fwlib64.dll via
P/Invoke) + `Driver.FOCAS.Shared` (MessagePack IPC contracts) + a C shim
DLL stand-in for unit tests. All of it is deleted; the driver is now a
single in-process managed assembly talking the FOCAS/2 Ethernet binary
protocol directly on TCP:8193.
Architecture
- Pure-managed `FocasWireClient` inlined at `src/.../Driver.FOCAS/Wire/`
(owner-imported — see Wire/FocasWireClient.cs for the full surface).
Opens two TCP sockets, runs the initiate handshake, serialises requests
on socket 2 through a semaphore, closes cleanly with PDU + socket
teardown. Both sync `IDisposable` and async `IAsyncDisposable`.
- `WireFocasClient` (same folder) adapts the wire client to OtOpcUa's
`IFocasClient` surface — fixed-tree reads, PARAM/MACRO/PMC addresses,
alarms. Writes return `BadNotWritable` by design — OtOpcUa is read-only
against FOCAS.
- `FocasDriverFactoryExtensions` now accepts `"Backend": "wire"` (default)
and `"Backend": "unimplemented"`. Legacy `ipc` and `fwlib` backends are
rejected at startup with a diagnostic pointing at the migration doc.
Deletions
- `src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Host/` — whole project + Ipc/,
Backend/, Stability/, Program.cs.
- `src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Shared/` — Contracts/, FrameReader,
FrameWriter, whole project.
- `tests/...Driver.FOCAS.Host.Tests/` + `.Shared.Tests/` — whole projects.
- `src/.../Driver.FOCAS/FwlibNative.cs` + `FwlibFocasClient.cs` — 21
P/Invokes + 7 `Pack=1` marshalling structs + the Fwlib-backed
`IFocasClient` implementation.
- `src/.../Driver.FOCAS/Ipc/` + `Supervisor/` — IPC client wrapper +
Host-process supervisor (backoff, circuit breaker, heartbeat, post-
mortem reader, process launcher).
- `scripts/install/Install-FocasHost.ps1` — NSSM service installer.
- `tests/.../Driver.FOCAS.Tests/{IpcFocasClientTests, IpcLoopback,
FwlibNativeHelperTests, PostMortemReaderCompatibilityTests,
SupervisorTests, FocasDriverFactoryExtensionsTests}.cs` — tests that
exercised the retired surfaces.
- `tests/.../Driver.FOCAS.IntegrationTests/Shim/` — the zig-built C shim
DLL that masqueraded as Fwlib64.dll.
Solution changes
- `ZB.MOM.WW.OtOpcUa.slnx` drops the 4 retired project refs.
- `src/.../Driver.FOCAS.csproj` drops the Shared ProjectReference, adds
`Microsoft.Extensions.Logging.Abstractions` for the optional `ILogger`
hook in `FocasWireClient`.
- `src/.../Driver.FOCAS.Cli.csproj` drops the six `<Content Include>`
entries that copied `vendor/fanuc/*.dll` into the CLI bin. CLI now uses
`WireFocasClient` directly.
- `FocasDriver` default factory flips to `Wire.WireFocasClientFactory`.
Integration tests
- New `tests/.../Driver.FOCAS.IntegrationTests/` project covering fixed-
tree reads (identity, axes, dynamic, program, operation mode, timers,
spindle load + max RPM, servo meters), user-authored PARAM / MACRO /
PMC reads, `DiscoverAsync` emission, `SubscribeAsync` + `OnDataChange`,
`IAlarmSource` raise/clear transitions, and `ProbeAsync` /
`OnHostStatusChanged`. 9 e2e tests against the focas-mock fixture
(Docker container with the vendored Python mock's native FOCAS/2
Ethernet responder).
- `scripts/integration/run-focas.ps1` orchestrates compose up → tests →
compose down. Dropped the shim-build stage + DLL-copy step + the split
testhost workaround (the latter only existed because of native-DLL
lifecycle bugs the shim tripped).
- Docker compose collapses from 11 per-series services to one `focas-sim`
service. Tests seed per-series state via `mock_load_profile` at test
start.
- Vendored focas-mock snapshot refreshed to pick up upstream's native
FOCAS/2 Ethernet responder (was 660 lines, now 1018) — the
pre-refresh snapshot only spoke the JSON admin protocol.
Tests
- 145/145 unit tests in `Driver.FOCAS.Tests` pass (was 208 pre-deletion;
63 removed tests exercised the retired IPC/shim/supervisor/Fwlib
surfaces).
- 9/9 integration tests pass against the refreshed mock.
- `FocasScaffoldingTests.Unimplemented_factory_throws_on_Create…` updated
to assert the new diagnostic message pointing at
`docs/drivers/FOCAS.md` rather than the now-gone `Fwlib64.dll`.
Docs
- `docs/drivers/FOCAS.md` rewritten for the managed wire topology —
deployment collapses to one `"Backend": "wire"` config block, no
separate service, no DLL deployment, no pipe ACL.
- `docs/drivers/FOCAS-Test-Fixture.md` updated — single TCP probe skip
gate instead of TCP + shim probe; fewer moving parts.
- `docs/drivers/README.md` row for FOCAS reflects the Tier-A managed
topology (previously listed Tier-C + `Fwlib64.dll` P/Invoke).
- `docs/Driver.FOCAS.Cli.md` drops the Tier-C architecture-note section.
- `docs/v2/implementation/focas-isolation-plan.md` marked historical —
the plan it documents was executed then superseded by the wire client.
- `docs/v2/v2-release-readiness.md` re-audited 2026-04-24. Phase 5
driver complement closed. FOCAS change-log entry added.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
||
|
|
a9b585ac5b |
Task #253 follow-up — bidirectional + subscribe-sees-change e2e stages
The original three-stage design (probe / driver-loopback / forward- bridge) only proved driver-write → server-read. It missed: - OPC UA write → server → driver → PLC (the reverse direction) - server-side data-change notifications actually firing (a stale subscription can still let a read-after-the-fact return the new value and look fine) Extend _common.ps1 with two helpers: - Test-OpcUaWriteBridge: otopcua-cli write the NodeId -> wait 3s -> driver CLI read the PLC side, assert equality. - Test-SubscribeSeesChange: Start-Process otopcua-cli subscribe in the background with --duration N, settle 2s, driver-side write, wait for the subscription window to close, assert captured stdout contains the new value. Wire both into test-modbus / test-abcip / test-ablegacy / test-s7 / test-focas / test-twincat after the existing forward-bridge stage. Update README to describe the five-stage design + note that the published NodeId must be writable for stages 4 + 5. Also prepend UTF-8 BOM to every script in scripts/e2e so Windows PowerShell 5.1 parsers agree on em-dash byte sequences the way PowerShell 7 already does. The scripts still #Requires -Version 7.0 — the BOM is purely defensive for IDE / CI step parsers. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
8d92e00e38 |
Task #253 — E2E CLI test scripts + FOCAS test-client CLI
The driver-layer integration tests confirm the driver sees the PLC, and
the Client.CLI tests confirm the client sees the server. Nothing glued
them end-to-end until this PR.
- scripts/e2e/_common.ps1: shared helpers — CLI invocation (published-
binary OR `dotnet run` fallback), Test-Probe / Test-DriverLoopback /
Test-ServerBridge (all return @{Passed;Reason} hashtables).
- scripts/e2e/test-<modbus|abcip|ablegacy|s7|focas|twincat>.ps1: per-
driver three-stage script (probe → driver-loopback → server-bridge).
AB Legacy / FOCAS / TwinCAT are gated behind *_TRUST_WIRE env vars
since they need real hardware (#222) or a licensed runtime (#221).
- scripts/e2e/test-phase7-virtualtags.ps1: writes a Modbus HR, reads
the server-side VirtualTag (VT = input * 2) back via OPC UA, triggers
+ clears a scripted alarm. Exercises the Phase 7 CachedTagUpstreamSource
+ ScriptedAlarmEngine path.
- scripts/e2e/test-all.ps1: reads e2e-config.json sidecar, runs each
present driver, prints a FINAL MATRIX (PASS/FAIL/SKIP). Missing
sections SKIP rather than fail hard.
- scripts/e2e/e2e-config.sample.json: commented sample — each dev's
NodeIds are local-seed-specific so e2e-config.json is .gitignore-d.
- scripts/e2e/README.md: full walkthrough — prereqs, three-stage design,
env-var gates, expected matrix, why this is separate from `dotnet test`.
Tasks #249-#251 shipped Modbus/AbCip/AbLegacy/S7/TwinCAT CLIs but left
FOCAS out. Since test-focas.ps1 needs it, the 6th CLI ships here:
- src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli: probe/read/write/subscribe
commands, AssemblyName `otopcua-focas-cli`. WriteCommand.ParseValue
handles the full FocasDataType enum (Bit/Byte/Int16/Int32/Float32/
Float64/String — no UInt variants; the FOCAS protocol exposes signed
PMC + Fanuc-Float only). Default DataType is Int16 to match the PMC
register convention.
Full-solution build clean (0 errors). FOCAS CLI wired into
ZB.MOM.WW.OtOpcUa.slnx. No .Tests project for the FOCAS CLI yet —
symmetric with how ProbeCommand has no unit-testable pure logic in the
other 5 CLIs either; WriteCommand.ParseValue parity will land in a
follow-up to keep this PR scoped.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|