Driver.FOCAS.Cli-005 follow-up: extend the SnapshotFormatter.FormatStatus
shortlist with the five Bad* codes the native-protocol mappers (FOCAS,
AbCip, AbLegacy) emit but which the shortlist previously left unnamed,
so they rendered only as severity-class 'Bad' instead of the documented
'BadDeviceFailure' / 'BadNotWritable' / ... names operators are told to
read off probe/write output.
Added entries:
0x80020000 BadInternalError
0x803B0000 BadNotWritable
0x803C0000 BadOutOfRange
0x803D0000 BadNotSupported
0x80550000 BadDeviceFailure
(BadTimeout 0x800A0000 was already added under Driver.Cli.Common-001.)
Tests: SnapshotFormatterTests gains a new [Theory]
FormatStatus_names_native_driver_emitted_codes covering the five names,
and the existing well-known [Theory] is extended with the same entries
to enforce exact '0x... (Name)' rendering. Suite now 47 green (was 42).
Flips Driver.FOCAS.Cli-005 from Deferred to Resolved; README regenerated.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
- Driver.FOCAS.Cli-001: WriteCommand.ParseValue now wraps numeric
FormatException / OverflowException as CliFx CommandException with
the offending value.
- Driver.FOCAS.Cli-002: SubscribeCommand's OnDataChange handler and the
banner both take a writeLock so notification-callback and main-thread
writes can't interleave; handler exceptions are warn-and-swallow.
- Driver.FOCAS.Cli-003: FocasCommandBase.ValidateOptions rejects
--cnc-port outside 1..65535, non-positive --timeout-ms, and
non-positive --interval-ms; ExecuteAsync calls it first.
- Driver.FOCAS.Cli-004: 'await using var driver' is the sole driver
disposal path; dropped the redundant explicit await ShutdownAsync.
- Driver.FOCAS.Cli-005 (Deferred): the fix lives in
Driver.Cli.Common.SnapshotFormatter — explicitly naming the
status-code shortlist there benefits every driver CLI. Left as a
Driver.Cli.Common follow-up.
- Registered the new tests/Drivers/Cli/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli.Tests
project in ZB.MOM.WW.OtOpcUa.slnx.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
- Driver.Modbus.Cli-003: ModbusCommandBase.ValidateEndpoint rejects
--port outside 1..65535, non-positive --timeout-ms, and --unit-id
outside 1..247.
- Driver.Modbus.Cli-004: wrapped SubscribeCommand's OnDataChange handler
body in a try/catch (warn-and-swallow) and serialised the console
write through a lock.
- Driver.Modbus.Cli-005: Probe / Read / Write now catch the
cancellation-during-init OperationCanceledException and print
'Cancelled.' instead of dumping a stack trace.
- Driver.Modbus.Cli-006: ProbeCommand.ComputeVerdict derives the headline
from BOTH the driver state and the probe snapshot's OPC UA quality
class so the headline can't disagree with the wire result.
- Driver.Modbus.Cli-007: docs/Driver.Modbus.Cli.md carries an explicit
'CLI scope' callout — the address-string grammar is a DriverConfig
JSON feature; the CLI takes the structured triple only.
- Driver.Modbus.Cli-008: pinned BuildOptions, ValidateEndpoint, the
region-validation guards, ComputeVerdict, and the cancellation-during-
initialize paths.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
- Driver.TwinCAT.Cli-001: TwinCATCommandBase.Validate rejects
non-positive TimeoutMs / IntervalMs and AmsPort outside 1..65535;
ExecuteAsync calls it first.
- Driver.TwinCAT.Cli-002: SubscribeCommand serialises every WriteLine
through a writeLock to remove the notification-callback vs banner
interleave risk.
- Driver.TwinCAT.Cli-003: SubscribeCommand.DescribeMechanism derives
the banner label from the returned ISubscriptionHandle.DiagnosticId
so it can't disagree with what the driver actually did.
- Driver.TwinCAT.Cli-004: introduced TwinCATTagCommandBase carrying
--poll-only + BuildOptions; BrowseCommand stays on the slimmer
TwinCATCommandBase so --poll-only no longer surfaces in browse --help.
- Driver.TwinCAT.Cli-005: ProbeCommand --type now carries the 't' short
alias to match the other commands.
- Driver.TwinCAT.Cli-006: 35 new tests covering Gateway / AmsAddress
parse / BuildOptions / PollOnly / browse-helpers / probe-alias /
mechanism derivation.
- Driver.TwinCAT.Cli-007: replaced the empty-init <inheritdoc/> with an
explicit summary warning future maintainers about the no-op init.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
- Driver.S7.Cli-004: 'await using var driver' is the sole driver
disposal path; dropped the redundant explicit await ShutdownAsync from
each command's finally.
- Driver.S7.Cli-005: deleted the stale empty
tests/ZB.MOM.WW.OtOpcUa.Driver.S7.Cli.Tests/ directory (the real test
project lives under tests/Drivers/Cli/).
- Driver.S7.Cli-006: S7CommandBaseBuildOptionsTests cover the probe
toggle, timeout mapping, host/port/CPU/rack/slot wiring, and tag list
passthrough.
- Driver.S7.Cli-007: re-added the SubscribeCommand handler comment
explaining the CliFx IConsole.Output usage and that the poll-thread
raises events.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
- Driver.AbLegacy.Cli-002: WriteCommand.Value description lists the full
true/false, 1/0, on/off, yes/no alias set.
- Driver.AbLegacy.Cli-003: SubscribeCommand serialises every WriteLine
via a per-execution consoleGate lock so the poll-thread OnDataChange
handler can't interleave with the banner.
- Driver.AbLegacy.Cli-004: dropped 'await using var driver' in favour of
a plain 'var driver' + explicit await ShutdownAsync in finally; the
driver is no longer shut down twice.
- Driver.AbLegacy.Cli-005: SubscribeCommand.IntervalMs description
carries the PollGroupEngine 250ms-floor caveat; docs/Driver.AbLegacy.Cli.md
spells out the same.
- Driver.AbLegacy.Cli-006: ProbeCommand --type now carries the short
alias 't' to match the other commands.
- Driver.AbLegacy.Cli-007: BuildOptionsTests cover the probe-disabled,
device-shape, tag-passthrough, timeout-propagation, and empty-tag-list
paths.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
- Driver.AbCip.Cli-003: SubscribeCommand prints the 'Subscribed' banner
BEFORE wiring OnDataChange so the main thread can't interleave its
write with the poll-thread handler.
- Driver.AbCip.Cli-004: AbCipCommandBase.Timeout and SubscribeCommand
validate TimeoutMs / IntervalMs and throw CommandException on
non-positive values.
- Driver.AbCip.Cli-005: every command now calls FlushLogging() in its
finally block.
- Driver.AbCip.Cli-006: Timeout init throws NotSupportedException with a
pointer at TimeoutMs instead of silently swallowing assignments.
- Driver.AbCip.Cli-007: added AbCipCommandBaseTests covering BuildOptions
shape, probe / controller-browse / alarm toggles, host address, family
selection, tag list passthrough.
- Driver.AbCip.Cli-008: rewrote the opening paragraph in
docs/Driver.AbCip.Cli.md to credit the six-CLI roster with a pointer
at docs/DriverClis.md.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Wrap all numeric/DateTime BCL parses in ParseValue with try/catch(FormatException)
and try/catch(OverflowException) that re-throw as CommandException, matching the
existing Bool path. Update ParseValue_non_numeric_for_numeric_types_throws to assert
CommandException (not FormatException), and add an overflow-edge test (Byte value 256).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
WriteCommand.ParseValue wraps FormatException/OverflowException as
CliFx CommandException so a bad --value yields a clean one-line CLI error
naming the value and target type instead of a raw .NET stack trace.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Driver.AbCip.Cli-001: WriteCommand.ParseValue wraps FormatException/
OverflowException as CommandException so bad --value input yields a clean
CLI error instead of a raw stack trace.
Driver.AbCip.Cli-002: probe/read/subscribe commands reject Structure types
up front (RejectStructure helper), matching the write guard.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
FormatStatus now matches named codes against code & 0xFFFF0000 (high-word
mask) rather than exact equality, so status codes carrying sub-code or flag
bits in the low 16 bits (e.g. 0x80050001) still resolve to their named class.
For codes not in the named shortlist a severity-class fallback using the top
2 bits always emits Good / Uncertain / Bad rather than bare hex.
Updated the stale FormatStatus_unknown_codes_fall_back_to_hex_only test (its
expectation became invalid once the severity-class fallback was added) and
added new Theory cases exercising both the high-word matching and the
severity-class fallback paths.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
SnapshotFormatter.FormatStatus mapped four OPC UA status names to
incorrect numeric codes, mislabelling operator-facing CLI output. The
codes were corrected to their canonical OPC Foundation
Opc.Ua.StatusCodes values:
BadTimeout 0x80060000 -> 0x800A0000
BadNoCommunication 0x80070000 -> 0x80310000
BadWaitingForInitialData 0x80080000 -> 0x80320000
BadNodeIdInvalid 0x80350000 -> 0x80330000
The Cli.Common project does not reference the Opc.Ua package (only
Core.Abstractions / CliFx / Serilog), so the hex literals were
corrected in place with a sync note rather than adding a heavy new
dependency.
SnapshotFormatterTests was updated: the [Theory] expectations now use
the correct spec codes and assert the full rendered form, plus a new
regression [Theory] confirms the pre-fix wrong names no longer apply.
All 24 tests pass.
findings.md: Driver.Cli.Common-001 set to Resolved; open count 6 -> 5.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.
- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
integration, install).
Build green (0 errors); unit tests pass. Docs left for a separate pass.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>