catthehacker/ubuntu:act-latest ships no iproute2, so fixture_host() fell back to 127.0.0.1 inside the
job container and every published-port fixture timed out (QuestDB is the first one probed over the
network). Read the default gateway from /proc/net/route in plain bash, warn when none is found, and log
the chosen host. Verified in that image on a user-defined network: gateway parsed, published port 200.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
The persistent NAT PKI (ae91e6b7) re-verified 2026-11-11: same thumbprint
1FBF8791... across --force-recreate on 10.100.0.35, matching the committed
opc-plc-nat-server.der; NAT class 7/7 against the shared stack and against a
CI-style throwaway container + docker-exec cert hand-off. MIN_EXECUTED stays
at 440: no hosted v2-integration run has reached the test step (#860).
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
Decision: CI stays hermetic (no dependency on the 10.100.0.35 box or its
state), but must run the same engine. integration-fixtures.sh now takes the
questdb/questdb:<tag> line from the #822 fixture compose file (10.0.1 today,
same as the docker-dev overlay) and fails 'up' if it is missing;
CI_QDB_IMAGE overrides for a trial. Documented in scripts/ci/README.md.
Co-Authored-By: Claude <noreply@anthropic.com>
#816 finding: the SDK checks that the server certificate names the host only
when a session is created with checkDomain:true. The driver, the AdminUI
browser and Client.Shared all called the 8-argument
DefaultSessionFactory.CreateAsync, which forwards checkDomain:false — so no
host-name check ever ran (why a trusted NAT cert for *.invalid browsed fine
over an IP in #813). When enabled the SDK (Session.OpenAsync ->
ValidateDomains -> FindDomain) compares ConfiguredEndpoint.EndpointUrl.IdnHost
— the CONFIGURED host, because OpcUaEndpointSelection/EndpointSelector
rewrote the advertised one — against the cert's DNS/IP SANs; secured
sessions only, and the auto-accept handler accepts a mismatch.
Policy: certificateValidation.validateServerHostName, tri-state. Unset =
OpcUaCertificateValidationOptions.DefaultValidateServerHostName = false, the
pre-#816 behaviour, so nothing changes on upgrade; true = validate the
configured host; false = explicit NAT/port-publish opt-out. Threaded into the
driver, the AdminUI browser (same JSON) and the AdminUI form (a select that
keeps "unset" unset), Client.Shared ConnectionSettings.ValidateServerHostName
and the CLI --validate-host-name. A driver refusal names the opt-out.
#818: the NAT fixture's /app/pki is on the opc-plc-nat-pki volume (verified:
same thumbprint across --force-recreate), its PUBLIC cert is committed as
Docker/nat/opc-plc-nat-server.der, and NatPublishedEndpointBrowseTests run
every secure browse on a throwaway PKI (internal browser seam): refusal with
nothing trusted, positive with the cert trusted (unset/false host check), and
a BadCertificateHostNameInvalid refusal with the check on. The trusted cert is
OPCUA_NAT_SERVER_CERT or the committed one (skip on thumbprint mismatch);
OPCUA_NAT_SERVER_CERT_TRUSTED is retired. CI exports its throwaway NAT
container's public cert. ServerHostNameValidationTests pin the driver against
the plain opc-plc. MIN_EXECUTED not raised (needs a hosted run): +6 in
v2-integration (440 -> 446), documented in scripts/ci/README.md.
Docker/nat/docker-compose.yml (stack /opt/otopcua-opcuaclient-nat on 10.100.0.35,
project: lmxopcua label): opc-plc 2.14.10 advertising --ph=otopcua-opc-plc-nat-private.invalid
on internal 50000, published on 50010, so every advertised URL is unreachable on host AND
port. Deployed; NatPublishedEndpointBrowseTests 3/3 against opc.tcp://10.100.0.35:50010
(and the secure case positive once, with the fixture cert temporarily trusted).
CI: integration-fixtures.sh starts a throwaway otopcua-ci-opcplc-nat (50110->50000) and
exports OPCUA_NAT_ENDPOINT; v2-e2e.yml points it at the shared stack. infra/README.md,
scripts/ci/README.md and the fixture README document it.
Scripted condition NodeIds are opaque ScriptedAlarmIds, so splitting them as a
topology path could never match an Equipment grant: a narrow equipment grant was
denied while a Cluster grant passed.
- OtOpcUaNodeManager binds each LIVE scripted condition instance to the
EquipmentId it was materialised under (only when it hangs under that folder);
dropped on remove / drop-recreate / equipment-subtree removal / rebuild; a
same-id re-materialise under another equipment re-parents and re-binds.
- DataPlaneAuthoritySnapshot carries EquipmentScopePaths (EquipmentId ->
[uns, Area, Line, Equipment]) decoded from the artifact by the same
AclScopePathResolver call that plants Equipment grants.
- DataPlaneAuthorizer.AuthorizeScriptedCondition re-reads key, grant and
generation per call (uncached) and evaluates at the owner path; unbound,
replaced or unplaceable owners deny under every grant. No id-split or
realm-root fallback.
- Native conditions (RawPath) and the ACL-off role gate are unchanged.
NodeIds and AlarmCommand.AlarmId are unchanged.
Sdk2OpaqueScriptedScopeBaselineTests deliberately flipped: it pinned the denial
and now pins owner-grant allow / sibling deny / cluster allow. Follow-up #808
(folder ids + Server-object event visibility for narrow UNS grants).
Owner decisions §14 #5/#6 as built (design §12.5):
- Scripting:Worker:Identity (default unset, Windows only, fail-closed validation): each worker
starts under a restricted token derived from the host's. Every privilege but SeChangeNotify is
removed; the restricting SIDs are NT SERVICE\OtOpcUaScriptWorker's SID + Everyone + Users +
RESTRICTED; the token and default DACLs are host + SYSTEM + identity + RESTRICTED. The worker
is created suspended, put in its Job Object before it runs, inherits only its stdio pipes, gets
an ACL'd work dir as TEMP, and runs with DOTNET_EnableDiagnostics=0. The identity is granted on
the host's window station and desktop, because USER32 init made coreclr.dll fail with
ERROR_DLL_INIT_FAILED on windev. The logon SID is not used because the host's process DACL
gives it PROCESS_VM_READ.
- The worker pipe on Windows always has an explicit protected DACL: host account + identity
only. There is no owner ACE, so an elevated host's Administrators gets no access.
- The worker treats access denied on its parent-pid poll as alive; the Job Object covers that case.
- scripts/install/Install-ScriptWorkerIsolation.ps1 + ScriptWorkerIsolation.psm1 are idempotent
and support -WhatIf, -Uninstall and -PlanOnly. They create the disabled anchor service, the
PeCacheDir ACL (protected, no Users, key and markers host-only, pe\ Modify for the identity),
read+execute on script-worker\, a ReadData deny on the install root, the outbound firewall
block on the worker exe, and optionally the host-service env.
- Tests: the dry-run harness scripts/install/tests/Test-ScriptWorkerIsolation.ps1 (46
assertions, mutation-checked); ScriptWorkerIdentityTests; WorkerIsolationTests, which cover
the pipe ACL, token access and a real restricted worker running a script, all green on windev.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
v2-integration.yml runs the Sql, Historian.SqlServer, Historian.QuestDb and OpcUaClient
integration projects against throwaway SQL Server/PostgreSQL/QuestDB/opc-plc containers
started by scripts/ci/integration-fixtures.sh, with a MIN_EXECUTED=440 floor. v2-e2e.yml is
manual/weekly, probes the shared fleet and skips cleanly when unreachable. v2-ci.yml is
functionally unchanged. Unverified on a hosted runner until first run.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV