Commit Graph

2 Commits

Author SHA1 Message Date
Joseph Doherty 4550486144 fix(health): active tier reports the cluster Primary, not the admin role leader
Closes the remaining half of #494, and corrects the half fixed in 8dd9da7d.

The shared ActiveNodeHealthCheck(role: "admin") answered the wrong question twice
over. It returns Healthy for any node LACKING the role, so all four driver-only
site nodes called themselves active and no consumer could find the Primary of a
site Cluster. And it selects by RoleLeader - the lowest-ADDRESSED member - which
is not where Akka places singletons.

Replaced with ClusterPrimaryHealthCheck ("cluster-primary"). One rule: this node
is active iff it is the OLDEST Up member carrying its own active role, where the
active role is admin when the node has it and driver otherwise. That serves both
consumers correctly - a fused admin node answers for admin, so Traefik pins the
AdminUI to the node hosting the singletons; a driver-only site node answers for
driver, which is exactly SelectDriverPrimary, the same election behind
IsDriverPrimary and the OPC UA ServiceLevel 250/240 split. Per-mesh scoping is
free after Phase 6: ClusterState.Members already contains only this node's own
Cluster.

SelectDriverPrimary is generalised to SelectOldestUpMemberOfRole so the
age-ordering rule has one implementation. Two copies of "oldest Up member of a
role" would be two chances to silently disagree about who is in charge, and the
tier and the redundancy snapshot must never disagree.

THE ROLE-LEADER HALF MATTERED IN PRACTICE, not just in theory. On the rebuilt rig
the two orderings diverge right now:

  akka leader (lowest address) = central-1
  oldest admin member          = central-2   <- hosts the singletons

8dd9da7d made the tier a real 503 but still selected by RoleLeader, so it would
have pinned Traefik to central-1 - the node NOT hosting the work. With this change
Traefik correctly routes to central-2.

Live-verified, exactly one 200 per mesh:

  MAIN     central-2 200   central-1 503     traefik: central-2 UP, central-1 DOWN
  SITE-A   site-a-1  200   site-a-2  503
  SITE-B   site-b-1  200   site-b-2  503

Tests: role-selection matrix and the startup-safe Degraded path in Host.Tests
(26 pass); parity between the tier's selector and the redundancy snapshot's, plus
role scoping, added to RedundancyPrimaryElectionTests, which forms a real two-node
cluster deliberately built so the oldest member is not the lowest-addressed one
(5 pass).
2026-07-24 12:43:27 -04:00
Joseph Doherty 50b55ee4b9 fix(redundancy): elect the Primary by cluster age, not by address
RedundancyStateActor derived the driver Primary from ClusterState.RoleLeader("driver").
Akka offers two different notions of a "first" member and they are not the same
one: role leader is the lowest-ADDRESSED Up member (host, then port), while
ClusterSingletonManager places singletons on the OLDEST — lowest up-number.

They agree on a freshly-formed cluster, which is why every existing test passed.
They diverge after any restart: the restarted node re-joins as the youngest while
keeping its address, so if it holds the lower address it becomes role leader while
the singletons stay put. The snapshot would then name a Primary that is not
hosting the work, and every Primary-gated surface follows it — inbound device
writes, native-alarm acks, the fleet-wide alerts emit, and the alarm-history
drain would all enable on the wrong node while the node actually running the
singletons stayed gated off.

BuildSnapshot now selects the oldest Up member carrying the driver role, matching
singleton placement. Leaving members are excluded: a node handing its singletons
over must not be named Primary.

NodeRedundancyState.IsRoleLeaderForDriver is renamed IsDriverPrimary, and
NodeHealthInputs.IsDriverRoleLeader likewise. Keeping the old names would have
left the wire contract asserting a derivation the code no longer uses — the same
drift that made this defect invisible.

Proven by a real two-node cluster rather than a mock. RedundancyPrimaryElectionTests
binds the first-joining node to the HIGHER port, so oldest and lowest-address name
different nodes, and includes a fixture assertion that the divergence actually
occurred — without it the real assertion could pass for the wrong reason. Positive
control: restoring the RoleLeader derivation turns exactly the two election tests
red while the fixture check stays green.

Runtime.Tests 440 passed, ControlPlane.Tests 82, Cluster.Tests 36.

Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-21 18:39:07 -04:00