Joseph Doherty 4b14feb373 fix(drivers): serialize driver-config enums as strings in AdminUI pages + probes
AdminUI driver-instance pages serialized enum config fields (S7 CpuType,
Modbus DataType/Region, AbCip PlcFamily, ...) as JSON *numbers* because each
page's _jsonOpts lacked a JsonStringEnumConverter. The driver factories,
however, deserialize into string-typed DTOs (+ lenient ParseEnum) and throw
when binding a JSON number to a string? — so an AdminUI-authored config
containing any enum field produced a blob the driver could not parse,
faulting the driver on deploy. Proven end-to-end for S7 and Modbus; latent
for AbCip/AbLegacy/TwinCAT/FOCAS/Galaxy/Historian. Only OpcUaClient was safe
(its factory + probe already carried the converter).

Add JsonStringEnumConverter to all 9 driver-instance pages' _jsonOpts and the
8 missing driver probes' _opts (factories unchanged — already string-via-
ParseEnum; strictly more permissive, also lets pages load hand-seeded
string-enum configs back into the form).

Also fix DriverProbeHandshakeE2eTests.AbCip_Green_AgainstSim to probe a real
sim tag (TestDINT) — the no-tags @raw_cpu_type fallback is rejected by the
ab_server sim with ErrorBadParam (a real ControlLogix returns ErrorNotFound,
which the probe treats as reachable; hardware-gated follow-up).

Tests: reflection guard over all driver pages' _jsonOpts (AdminUI.Tests);
factory round-trip + numeric-form-throws guards for S7 and Modbus.

Found by running the never-before-run FB-9/FB-10 live verifies.
2026-06-19 04:52:47 -04:00
Joseph Doherty 5df3c73204 fix(probe): bound AbLegacy handshake by timeout CTS + stop sw; correct FOCAS timeout comment (code-review) 2026-06-16 07:03:55 -04:00
Joseph Doherty 21f3e8feab feat(probe): AbLegacy Test-Connect opens a real PCCC session (libplctag init)
Replaces the bare-TCP AbLegacyDriverProbe with a two-phase probe:
Phase 1 is the existing TCP preflight; Phase 2 initialises a
LibplctagLegacyTagRuntime (Protocol.ab_eip + per-family PlcType) to
open a real PCCC-over-EIP session, using AbLegacyProbeOptions.ProbeAddress
("S:0") as the probe tag. Status-code discrimination mirrors the AbCip
probe: ErrorNotFound/ErrorNoMatch/ErrorBadDevice → Ok=true "controller
reachable"; transport errors → Ok=false "handshake failed".
Adds AbLegacyDriverProbeTests (5 unit tests, all green, 168 total).
2026-06-16 06:44:15 -04:00
Joseph Doherty c19d124e89 feat(drivers): TCP-connect IDriverProbe for all 9 driver types
Cheap-and-fast probe: open TCP socket to the configured endpoint,
close immediately. Surfaces SocketError on failure, latency on
success, "timed out" on caller cancel. Sufficient for the AdminUI
Test Connect "can we reach the host?" question. Richer protocol-
level probes (OPC UA session open, FOCAS handshake, gRPC ping)
are a documented follow-up. Each probe registered as
AddSingleton<IDriverProbe, X> in DriverFactoryBootstrap so they
flow through DI into AdminOperationsActor.

Historian.Wonderware returns a clean "TCP probe not applicable"
result because it communicates over a Windows named pipe, not TCP.
Also adds OpcUaClient + Historian.Wonderware.Client project
references to Host.csproj (both were missing from the driver
ItemGroup).
2026-05-28 10:53:42 -04:00