Joseph Doherty 09e0fe1841 fix(focas): a returned status never ends a device's batch; round-2 minors (#740 review round 2)
N1: linkDown is set only when NO reply arrived, i.e. a timeout, a transport exception or
a connect failure. A status the CNC returned proves it answered. EW_REJECT and every
unlisted rc map to BadCommunicationError, so a deterministic rc on one tag used to fail
every later tag of a reachable control on every poll. The comms-classed status still
degrades health. The coalescer already treated a returned refusal this way; it is
unchanged.

Tests: a returned EW_REJECT on tag 1 leaves tags 2 and 3 read and Good (red before). A
timeout still fails the rest without reading them (positive control).

Minors:
- m1: the _lifecycleLock doc now covers the health transitions it also guards.
- m2: the NoteFixedTreeFailed summary says a refusal credits the answer.
- m3: ReadAsync stamps a failed batch's exception with the generation the batch started
  under, and HandlePollError degrades that generation only.
- m4: the fixed-tree "blip" absence check runs unconditionally under a wide budget, and
  asserts that both ticks landed inside it.
- m5: direct unit cases for the coalescer link-down paths. A transport fault on the first
  range fails the second range and the per-tag tag without reading them. A connect
  failure costs one connect per batch. CncRelay.Up() retries the re-bind.

Refs #740
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 14:55:37 -04:00
Joseph Doherty de54b23b1a test(focas): wire-level cases for fixed-tree health and the legacy alarm layout (#740 review I2)
Against focas-mock:
- H15: a local TCP relay in front of the shared mock takes "the CNC" away and brings it
  back without stopping the fixture. A FIXED-only driver goes Degraded with
  LastSuccessfulRead frozen and its value Bad, then returns to Healthy with Good values
  (the positive control).
- H20: the mock answers cnc_rdalmmsg2 in the 80-byte legacy layout. Nineteen alarms
  (1,520 B = 20 x 76) now decode as the 19 seeded alarms; the old length test gives 20,
  verified red. A 3-alarm reply is the control.

Refs #740
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT