Joseph Doherty 3f85ba985e fix(mqtt): stop disposing the primary-host gate a live reconcile still holds
Driver.Mqtt-006 (Low, concurrency). DisposeAsync disposed _gate while StopAsync
cancels the reconcile loop WITHOUT awaiting it, so a ReconcileAsync already in
flight could be inside _gate.WaitAsync, or on its way to the finally-release,
when the semaphore went away. The release then threw ObjectDisposedException
naming SemaphoreSlim, logged as a reconcile failure — telling an operator
nothing about what happened and hiding whatever the reconcile was really
failing on.

Left undisposed, matching MqttConnection's documented rule for its own lifecycle
primitives and its stated rationale: a late callback racing teardown should be a
benign no-op rather than an ObjectDisposedException naming the wrong type. Two
lifecycle types in one module disagreeing about this is what gets copied into
the third. Nothing is leaked — the gate holds no timer and no registration — and
ClaimAsync still re-checks _disposed under it, so no claim can be created after
dispose either way.

Test is deterministic rather than timing-dependent: the gate is taken before the
connect starts, so a MiniBroker in blackhole mode (TCP accepted, CONNECT never
answered) accepting the socket proves the claim is inside the gate when dispose
runs. RED: log.Captured contained "ObjectDisposedException".
2026-08-10 07:58:38 -04:00
Joseph Doherty 2298485bda fix(mqtt): a reconnect that re-establishes nothing tears the session down
Driver.Mqtt-007 (Low, error handling). OnReconnectedAsync throws when a
re-subscribe is granted zero filters — MqttConnection's contract is that a
throwing Reconnected subscriber tears the fresh session down and retries under
backoff, because a connected-but-deaf driver is the one outcome this path must
never serve. But when the live subscribed topics resolved to zero filters in the
first place it logged a warning and returned, reaching the same "nothing was
re-established" state by a different route and giving it the opposite answer.

Throw there too, and say so in the remarks so the type states ONE rule. It costs
no other tag — every live topic is in the set that resolved to nothing, so there
is nothing left flowing to protect, which is the whole reason the partial-
rejection case is exempt — and it is not permanent: the retry runs against
whatever Register has published by then.

Test reaches the state the only way production can: Register prunes
_subscribedTopics of the topics its new table no longer carries, but a SUBSCRIBE
already in flight records its own topic AFTER that prune ran, so a deploy landing
inside the round-trip leaves a live topic no authored tag resolves to. Paired
with the control that a reconnect with no live subscriptions at all stays a
no-op — throwing there would tear down the session of every driver whose tags
have not been subscribed yet.
2026-08-10 07:58:29 -04:00
Joseph Doherty 5d4dd17d7f fix(mqtt-transport): warn when a configured password is dropped for want of a username
Driver.Mqtt.Transport-002 (Low, correctness). Credentials were attached only
when Username was non-empty, so a config carrying a Password and no Username
connected anonymously with the secret silently discarded — the deployment reads
as authenticated and is not, which is the direction an operator cannot see from
the config.

Warned rather than sent. MQTT 3.1.1 may not carry a password without a
username, so the password-only CONNECT is not available on every protocol
version this factory serves, and synthesizing one under V500 only would change
the wire behaviour of deployments that connect happily today. The configured
values stay authoritative; the drop just stops being silent. The secret is
never formatted into the message.

Tests: the warning fires and does NOT contain the password, plus the falsifying
control that an ordinary anonymous config (neither credential set) stays silent
— without it the fix could warn on every connect and still pass.
2026-08-10 07:58:19 -04:00
Joseph Doherty d68009106b merge: Mqtt runtime + Transport code review — deaf-reconnect subscription reset (High), teardown-before-reinit session leak (High), timeout normalization, dead CA-pin warning; 12 findings 2026-08-10 07:02:15 -04:00
Joseph Doherty 147b624437 merge: Calculation + OpcUaClient.Session code review — warm-up gate before evaluation (spurious script-throw warnings), evaluator logger wiring, probe JSON-leniency parity; 7 findings 2026-08-10 07:00:33 -04:00
Joseph Doherty c58e833aee merge: Mqtt Contracts+Browser code review — wildcard PUBLISH refusal (whole-driver outage path), Sparkplug segment shape rules, rebirth-scope wildcard gate; 12 findings 2026-08-10 07:00:22 -04:00
Joseph Doherty 978eeda753 merge: MTConnect family code review — sample-pump hot-loop backoff, probe deviceName path, stale-premise docs; 9 findings (High browse-commit String coercion recorded cross-module) 2026-08-10 07:00:09 -04:00
Joseph Doherty 9ccc0d5678 merge: Sql family code review — default-schema fallback (whole-driver outage path), rowSelector doc fix, dead SqlClient ref; 18 findings recorded across 4 modules 2026-08-10 06:59:53 -04:00
Joseph Doherty b4a03b4baa fix(calculation): probe JSON options stricter than the real spawn/reinit path (review)
CalculationDriverProbe.Opts (Test-Connect) omitted AllowTrailingCommas and
ReadCommentHandling that CalculationDriverFactoryExtensions.JsonOptions
(spawn) and CalculationDriver.ReinitJsonOptions (in-place ApplyDelta) both
set, so a config blob the real deploy path tolerates could fail Test-Connect
as "invalid JSON" even though deploying it would succeed. Aligned the three
option sets. Also adds CalculationDriverProbeTests.cs, which previously did
not exist at all for this driver type's Test-Connect surface.

Part of code-reviews/Driver.Calculation/findings.md (-003, -004).
2026-08-10 06:59:29 -04:00
Joseph Doherty a836e0d983 fix(calculation): dead logger cast + warm-up evaluated before change-gate (review)
Code review of Driver.Calculation found two real defects, both TDD-fixed:

- CalculationDriver's ctor tried to reuse its ILogger<CalculationDriver> as the
  evaluator's ILogger<CalculationEvaluator> via an `is` check that can never
  succeed (unrelated closed generics), so CalculationEvaluator always ran with
  a NullLogger regardless of what the driver was constructed with. Fixed by
  having CalculationEvaluator accept the non-generic ILogger instead.

- EvaluateTag called the evaluator BEFORE checking whether every declared
  dependency had arrived, so a multi-dependency change-triggered calc tag
  evaluated its script against a partial snapshot on every warm-up tick.
  VirtualTagContext.GetTag returns a Bad snapshot (.Value == null) for a
  missing dep, so the idiomatic `(double)ctx.GetTag("x").Value` cast throws
  NullReferenceException — caught and logged as a spurious "script threw"
  script-log Warning on ordinary deploy/restart warm-up, for the standard
  multi-input calc-tag shape. Fixed by gating evaluation itself on
  "all deps arrived", not just the publish.

See code-reviews/Driver.Calculation/findings.md for full detail (5 findings:
001-004 Resolved, 005 Open/cross-module).
2026-08-10 06:59:23 -04:00
Joseph Doherty 2b4b3fcbbf fix(mqtt): session-rebind subscriptions, re-init teardown, timeout clamp
Findings from the per-module review of Driver.Mqtt at b990adae
(code-reviews/Driver.Mqtt/findings.md records all ten; these are the fixed
ones).

Driver.Mqtt-001 (High) — MqttSubscriptionManager._subscribedTopics is a claim
about the broker session it established filters on, and AttachTo never cleared
it, but the manager OUTLIVES a session rebuild (AdoptOptions keeps it whenever
the ingest identity is unchanged). After a driver-host reconnect
(ShutdownAsync + InitializeAsync, the #527 watchdog's retry) or a
ReinitializeAsync that only changed the endpoint/credentials, the host's
re-subscribe resolved an empty pending set, sent no SUBSCRIBE at all, and left
the driver Connected/Healthy on a session carrying ZERO subscriptions — no
error, no Bad status, values frozen until the new session happened to drop.
AttachTo now forgets them, mirroring SparkplugIngestor.AttachTo's reset.

Driver.Mqtt-002 (High) — InitializeCoreAsync published _connection and
_primaryHost over whatever the driver already held, so a second initialize
stranded a connected, self-supervising broker session (plus a second Sparkplug
primary-host claim) that no later dispose could reach. Reachable without any
teardown of ours via DriverInstanceActor.AdoptConfigDuringInit. Now tears down
first, under the gate both callers already hold.

Driver.Mqtt-003 (Medium) — connectTimeoutSeconds is [Range]-annotated but
unvalidated on the runtime path; 0 makes every deadline fire immediately and a
negative value throws ArgumentOutOfRangeException out of ShutdownAsync and
DisposeAsync. Normalized once, at the seam every options instance passes.

Also: ShutdownAsync keeps the live last-message instant (-004), three usings
left behind by #512 removed (-005), stale remarks corrected (-009, -010), and
docs/drivers/Mqtt.md now distinguishes the two kinds of reconnect.

Tests 708 -> 713. All three regression tests were confirmed to fail against
the un-fixed code, with two controls that pass in either state.
2026-08-10 06:59:18 -04:00
Joseph Doherty 69ad376f0d review(Driver.Sql): findings + fix the missing default-schema fallback, the rowSelector doc, and a dead package ref
Driver.Sql-001 (Medium): SqlCatalogLoader.ReadDefaultSchemaAsync documented a
fallback to the sole visible schema when the server reports no default schema and
did not implement it, so a login with no DEFAULT_SCHEMA (or a Postgres search_path
that resolves to nothing) rejected EVERY unqualified authored table at the catalog
gate — a whole-driver BadNodeIdUnknown outage against a healthy database. Fixed;
SqlCatalogDefaultSchemaTests written red first, with a control proving the
ambiguous multi-schema case still refuses to guess.

Driver.Sql-003 (Medium): docs/drivers/Sql.md spelled the WideRow row selector at
the top level, but the parser reads those keys only inside a nested rowSelector —
a tag authored from the doc is refused and reads BadNodeIdUnknown (the #552 class,
via the documentation). Also removed the documented-but-nonexistent pollIntervalMs
per-tag field.

Driver.Sql-007 (Low): dropped the unused Microsoft.Data.SqlClient PackageReference
left behind by the .Dialect extraction (#526).

Open: 002 (no IN-list chunking vs the 2100/1000 provider bind caps), 004, 005, 006,
008, 009, 010.
2026-08-10 06:58:08 -04:00
Joseph Doherty a86a09767c test(historian-gateway): cover GatewayHistorianValueWriter + HistorizationOutboxEntrySerializer offline
Driver.Historian.Gateway-003 (Medium): both were exercised only by the
env-gated Category=LiveIntegration suite (skips cleanly offline) or only
indirectly through FasterLogHistorizationOutboxTests with single-char
ASCII tags. Adds direct offline unit coverage for the value writer's
ack-to-bool mapping, timestamp presence/absence, and non-throwing
contract (via the existing FakeHistorianGatewayClient double), and for
the serializer's Serialize/Deserialize round trip incl. a multi-byte
UTF-8 tag, an empty tag, and ushort/double boundaries.
2026-08-10 06:53:47 -04:00
Joseph Doherty 55b12dc217 fix(historian-gateway): map alarm severity numerically; dispose provisioner's gRPC channel
Driver.Historian.Gateway-001 (High): AlarmEventMapper wrote the alarm's
Severity wire property as the .NET enum name (e.g. "High"), but
EventMapper's read side int.TryParse()s that same property and silently
falls back to the minimum severity on any unparseable value - so every
alarm event's severity round-tripped through this module's own mappers
collapsed to 1 (Low), contradicting AlarmHistorianEvent.Severity's own
documented contract ("mapped to Historian's numeric priority"). Now
mapped through a numeric priority mirroring the existing
NativeAlarmProjector.MapSeverity convention (200/500/700/900).

Driver.Historian.Gateway-002 (Low): GatewayTagProvisioner never disposed
its IHistorianGatewayClient, unlike its GatewayHistorianDataSource /
GatewayAlarmHistorianWriter siblings. Now implements IAsyncDisposable so
the DI-owned singleton's gRPC channel closes gracefully at shutdown.

Both TDD: new/corrected tests confirmed RED against the pre-fix code.
2026-08-10 06:53:41 -04:00
Joseph Doherty 3118213772 fix(mqtt-browser): reject a wildcard rebirth scope before any NCMD leaves
SparkplugRebirthScope (the AdminUI's typed input) rejects '+'/'#' and its own
remarks say it is 'advisory, not the gate' because MqttBrowseSession
.ResolveRebirthTargets 'refuses an unusable one BEFORE any message leaves'. That
claim was false: the bare {group}/{edgeNode} branch — honoured on purpose, since a
node that has not birthed is the prime rebirth target — gated on IsUsableLabel,
which checks length and control characters only. A scope of 'Plant1/#' therefore
published spBv1.0/Plant1/NCMD/# , a PUBLISH the MQTT spec forbids and a conformant
broker answers by closing the browse connection; '+' would have fanned one
operator click across every matching edge node.

The check is a separate IsUsableRebirthSegment rather than a tightening of
IsUsableLabel: that helper also judges Sparkplug METRIC names, which are arbitrary
publisher-chosen UTF-8 and never part of a topic, so tightening it there would drop
legitimate metrics from the tree. Cases 1 and 2 cannot reach this shape — their ids
come off SparkplugTopic.TryParse, which already rejects both characters.

Driver.Mqtt.Tests 724 (was 708).
2026-08-10 06:51:59 -04:00
Joseph Doherty 6c63bf8fab fix(mtconnect): back off a /sample re-baseline that resolved nothing; scope Test Connect to the configured device
Driver.MTConnect-001 (Medium): StreamVerdict.Reopen reset the reconnect ladder
unconditionally. The InvalidDataException catch that routes an Agent OUT_OF_RANGE
to a /current re-baseline also catches an unparseable chunk and an over-sized
multipart part - neither of which a re-baseline can resolve - so the pump reopened
and failed with no delay at any point: two HTTP requests and one Warning per
iteration, forever. The Reopen arm now uses the same discriminator the transient
arm does (did THIS connection deliver a chunk?), so a buffer roll behind a working
stream still reopens instantly while a re-baseline that resolved nothing advances
BackoffFor.

Driver.MTConnect-002 (Medium): MTConnectDriverProbe requested {AgentUri}/probe
while MTConnectAgentClient requests {AgentUri}/{DeviceName}/probe, so a mistyped or
since-renamed deviceName showed GREEN on Test Connect and then Faulted the driver
at InitializeAsync (an unknown device path answers MTConnectError under HTTP 200).
The probe's minimal DTO now reads deviceName - the rule is 'which keys compose the
URL', not 'which keys are cheap to read'.

Driver.MTConnect-008 (Low): corrected two stale claims that a since-changed
RawBrowseCommitMapper invalidated (see Driver.MTConnect-003, which remains open and
belongs in AdminUI), and made DiscoverAsync log the options snapshot it
deliberately read once instead of the field.

Tests: 538 pass (534 base + 4 new, each red before its fix); AdminUI.Tests 1466 pass.
2026-08-10 06:51:39 -04:00
Joseph Doherty 6eace4bbba fix(mqtt-contracts): refuse unpublishable write destinations and advise on them at deploy
A wildcard writeTopic was published verbatim. MQTT-3.3.2-2 forbids a wildcard in a
PUBLISH topic and a conformant broker answers a protocol violation by closing the
connection — which for this driver is the one connection every subscription lives
on, so a single write to a mis-authored tag took the whole driver dark. The
Sparkplug side had the same hole plus a worse one: the binding tuple IS the
NCMD/DCMD topic, so a '/' in groupId/edgeNodeId/deviceId silently addressed a
different edge node than the tag names.

MqttWriteEncoder now refuses both as NoWriteDestination (-> BadNotWritable); the
read path is untouched. metricName is exempt on purpose — it rides in the payload
and Sparkplug's own canonical names use '/'.

MqttTagDefinitionFactory.Inspect gained the matching ADVISORIES (never rejections
— the mappers accept these blobs, and the gate must never be stricter than the
runtime). Both rules were already hard errors in the AdminUI's typed editor, but
that is one authoring path of several: the raw-JSON textarea, CSV import and the
API all reach the deploy gate directly, so the authoring surface was stricter than
the gate — the drift class the #549-#559 arc exists to close.

Shared shape rules single-sourced in the new internal MqttAddressRules.

Driver.Mqtt.Tests 724 (was 708); AdminUI.Tests 1466; ControlPlane.Tests 261.
2026-08-10 06:51:39 -04:00
Joseph Doherty 621a9e5dc2 fix(mqtt): runtime mappers no longer refuse leading-whitespace TagConfig — JsonDocument.Parse + ValueKind is the single framing authority (#559)
FromTagConfig and FromSparkplugTagConfig each carried a framing pre-check
(`tagConfig[0] != '{'`) evaluated on the UNTRIMMED string, so a TagConfig blob
with leading whitespace was refused by MQTT alone and the tag read
BadNodeIdUnknown forever — while the other six structural-parse drivers
(Modbus, S7, AbCip, AbLegacy, TwinCAT, FOCAS) hand the identical blob to
JsonDocument.Parse, which skips leading whitespace per the JSON spec.

The clause is dropped (the blank guard stays). JsonDocument.Parse plus the
root-ValueKind check now decide framing, exactly as for the six siblings: an
array/number/string root fails ValueKind, non-JSON is a JsonException. The gate
was a validator, not a discriminator — no caller (MqttSubscriptionManager,
SparkplugIngestor, MqttTagConfigModel, Inspect) used the first byte to pick a
format — so verdicts are identical for every input except whitespace-padded
JSON objects, which now get their content's verdict.

Inspect needs no logic change (it has trimmed since #556 and hands the RAW
reference to the mappers), but its comments claimed the padded-blob refusal was
production-reachable; rewritten. That shape was also MQTT's only vehicle for the
catch-all backstop, which is now unreachable-today like FOCAS's — so its test is
replaced by the same count-relation pin, and the backstop code stays as
defence-in-depth.

Tests: both mappers pinned by padded-vs-unpadded DEFINITION equality (a record,
so field-wise), padded non-object/malformed negative controls, an Inspect
verdict+inspection parity theory over the accepted AND rejected corpus with an
anti-vacuity control, and a padded MQTT corpus entry in the AdminUI
authoring/runtime parity suite.
2026-08-10 03:36:46 -04:00
Joseph Doherty be15ed160a merge: #556 + #557(Mqtt) — Inspect pre-filters trim before framing; rejection vs advisory classified structurally (backstop gates on rejections only); Mqtt union verdict kept with a mode-dependency advisory 2026-08-10 03:08:08 -04:00
Joseph Doherty f5475868f7 fix(inspect): trim before the framing check; stop advisories swallowing the backstop (#556); pin the MQTT payloadFormat mode contract (#557 item 2)
#556 item 1 — leading whitespace defeated every Inspect's pre-filter. Seven
factories (Modbus/S7/AbCip/AbLegacy/TwinCAT/FOCAS/Mqtt) tested
`reference[0] != '{'`, so a padded blob returned EMPTY and a tag the driver
refuses deployed clean. The check now trims first, matching the idiom
Sql/Calculation/MTConnect/OpcUaClient already used. The raw reference is still
what is handed to the mapper — the driver reads the stored blob, not a trimmed
copy — so the gate keeps mirroring the runtime rather than becoming lenient.
Both directions are pinned: a padded blob the mapper accepts still draws
nothing, and one that is not object-framed AFTER trimming still draws nothing
(it is not an equipment-tag TagConfig at all).

Six of the seven mappers hand the blob to a whitespace-tolerant
JsonDocument.Parse, so their verdict is unchanged by padding. MQTT is the
exception: both its readers carry the same framing gate, so a padded blob is
genuinely refused — which is why the untrimmed pre-filter was a real defect
there and not a cosmetic mismatch.

#556 item 2 — FOCAS and MQTT appended advisories unconditionally and then gated
the catch-all rejection message on `warnings.Count == 0`, so an advisory (which
fires on ACCEPTED blobs too, and says nothing about a refusal) silently
swallowed the only message naming a refusal nothing else can. The two classes
now accumulate in SEPARATE lists and the backstop gates on the rejection count
alone — structural, not string matching. MQTT's swallow was reachable in
production (a padded blob its readers refuse while every describe branch finds
the parsed document well-formed); FOCAS's backstop is currently unreachable by
audit, so its guard is protective.

#557 item 2 — decided and pinned: KEEP the union verdict. Evidence:
FromSparkplugTagConfig hard-codes PayloadFormat=Json and never consults the key;
only MqttSubscriptionManager (the Plain ingest path) decodes by it; and
MqttTagConfigModel.ToJson deliberately omits the key entirely in Sparkplug mode
(#513). So a Sparkplug driver genuinely serves the tag and rejecting it would be
stricter than the runtime. The cost — served behaviour depends on the driver's
MqttMode, which no tag row records — is paid by an ADVISORY naming the key and
the mode dependency, not by changing the verdict, so both gates keep agreeing.
The same invalid value on a blob the union REFUSES stays a rejection; the class
is decided by the accept gate, never by the key.

Falsified: reverting Modbus's trim reddens the padded-rejection theory;
neutering MQTT's backstop guard to the pre-#556 shape reddens the
advisory-plus-unnameable-rejection test; disabling the #557 advisory reddens the
contract pin; and for FOCAS, removing a describe branch alone stays green (the
backstop covers it) while additionally neutering the guard goes red.
2026-08-10 03:07:18 -04:00
Joseph Doherty 93a058287c merge: #557 (OpcUaClient half) — editor reads the legacy PascalCase NodeId at the reader's presence-shadows precedence and drops it on save; #554 stale exemption removed with the anti-vacuity guard as control 2026-08-10 03:02:12 -04:00
Joseph Doherty be5899bc7d fix(adminui): OpcUaClient editor reads the legacy PascalCase NodeId at the reader's precedence (#557 item 1)
`OpcUaClientTagDefinitionFactory.TryReadNodeId` still honours a legacy PascalCase
`NodeId` when the v3 camelCase `nodeId` is wholly absent, but
`OpcUaClientTagConfigModel` read only `nodeId` — so a legacy blob was SERVED by
the driver yet opened with an empty reference field and could not be saved
untouched. Authoring stricter than the reader, which #554 names as never
legitimate: the editor was blocking config the runtime honours.

Fixed with the #550 pattern (read both spellings, normalise on save), NOT by
retiring the spelling from the reader — that would break every legacy blob the
driver currently serves at the next deploy, a data-plane regression traded for
an editor asymmetry.

The precedence is PRESENCE-shadows, not first-non-blank. The reader's
`TryGetProperty("nodeId", out n) || TryGetProperty("NodeId", out n)`
short-circuits on the mere PRESENCE of the camelCase key and then checks
string-and-non-blank ONCE, so a blank / non-string / JSON-null `nodeId` beside a
valid legacy `NodeId` is a REJECTED blob, not a fallback. Copying MTConnect's
`FirstNonBlank` walk here would have made authoring WEAKER than the reader —
the same defect in mirror image.

- `NodeIdKeys` drives both halves, so the read and the drop cannot drift.
- `ToJson` writes `nodeId` and drops `NodeId`; the TagModal history-merge keys
  (`isHistorized` / `historianTagname`) are disjoint and untouched.
- `Validate`'s required-reference fast path is now precedence-aware by
  construction, so it agrees with the #554 parse consult across the whole
  rejection surface.
- The `TagConfigNonEnumParityTests` exemption for OpcUaClient is REMOVED — its
  anti-vacuity guard `Every_deliberately_stricter_entry_is_still_exactly_that`
  went red on the fix, which is this change's falsification control. The legacy
  shapes moved into the corpus, where both fleet theories now cover them.

Tests: a nine-row precedence theory driving the authoring verdict against the
READER's verdict per shape, on the original blob AND on the `ToJson()` output;
no-retype (legacy loads showing its reference, saves canonical, same node id
before and after); no-drift (output never carries `NodeId`). Each half was
reverted in isolation to confirm it reddens tests of its own: read-only-revert
=> 6 red incl. the fleet parity theory; drop-only-revert => 4 red.

Suites: AdminUI.Tests 1459/1459, ControlPlane.Tests 261/261,
Driver.OpcUaClient.Tests 143/143, Driver.OpcUaClient.Browser.Tests 10/10.
2026-08-10 03:01:41 -04:00
Joseph Doherty 17130d9c82 test(parity): consolidate the browse-commit guard onto one list; key browsers off DriverTypeNames (#558)
Two guards enumerated the same RawBrowseCommitMapper.BuildTagConfig seam against
two hand-authored lists, which can only drift. The older one's list was also
misnamed: DriverDispatchMapParityTests.NonBrowsableDriverTypes really meant
"types that produce the generic key" — AbLegacy is genuinely non-browsable yet
correctly absent from it, because it has a typed branch.

Retire the older fact. RawBrowseCommitMapperParityTests.GenericKeyExemptions is
now the single hand-authored list for this seam: named for what it holds, one
written reason per entry, and checked against a DI-derived browsable set rather
than a second list. The one assertion the retired fact made that nothing here
covered — set EQUALITY, i.e. an exemption must still DESCRIBE the mapper — moves
across as Every_generic_key_exemption_still_commits_to_the_generic_key. Without
it, a driver that gained a typed branch would keep a silently inert exemption.

Item 2: OpcUaClientDriverBrowser and GalaxyDriverBrowser returned string
literals ("OpcUaClient", "GalaxyMxGateway") where Sql/Mqtt use DriverTypeNames.
The values matched, and nothing guarded that. Repoint both at the constants —
DriverTypeNames.Galaxy carries the identical value — and add
Every_registered_browser_is_keyed_by_a_declared_driver_type_name over the same
AddAdminUI() read-back. Compared ORDINALLY: BrowserSessionService indexes on the
exact persisted string, and case-only drift (TwinCat/TwinCAT) is what
DriverTypeNames exists to end. Browser projects are out of reach of
DriverTypeNamesGuardTests, which pins the driver FACTORIES' names.

Falsified, four ways, each red naming the offender and green on revert:
  - #555 re-run: disabling the Sql branch reddens the two enumeration facts
    ("...no dedicated BuildTagConfig branch...: Sql"), the same catch the
    retired fact made.
  - giving Modbus a typed branch reddens ONLY the new stale-exemption fact,
    proving it is not redundant with the four that were already there.
  - SqlDriverBrowser.DriverType => "SQL" and Galaxy => "GalaxyMXGateway" each
    redden the new browser-key guard by name — case-only typos, which an
    OrdinalIgnoreCase compare would have waved through.
2026-08-10 02:56:05 -04:00
Joseph Doherty 7cfe7b4a24 merge: #554 — authoring models consult the driver's own runtime parse (TagConfigParseGate): verdict from the parse, wording from Inspect; five drivers' non-enum gaps closed, deliberately-stricter rules kept and pinned 2026-08-10 01:55:31 -04:00
Joseph Doherty 5ca4f8041d fix(adminui): authoring models consult the driver's own parse for non-enum TagConfig rules (#554)
#549/#551 made every typed editor judge its driver's enum KEYS against the runtime's
own reader and stopped there. Every other reason a reader refuses a tag met no gate
until deploy, or until the driver silently skipped the tag: an absent Modbus `region`,
an `"address":"notanumber"`, an S7 `stringLength` of 300, a TwinCAT `dataType:
"Structure"` (a VALID enum name the reader refuses), a Sql blob the parser cannot
recognise as Sql at all, an MQTT `"qos":null`.

Rather than hand-mirroring N more rules into N models — the drift #551 closed on the
deploy side — each `<Driver>TagConfigModel.Validate()` now asks its driver's own parse
whether it would read the AS-LOADED blob, via the new `TagConfigParseGate`. One
authority for the verdict AND the wording.

Two cautions are load-bearing and are pinned by tests:

- The gate is the PARSE VERDICT, never "the inspector said something". FOCAS, MQTT and
  Calculation inspectors emit advisories for blobs their reader ACCEPTS, so a
  non-empty-inspection gate would make the modal stricter than the runtime and leave
  rows nobody can save (#520/#535). Inspect is consulted only to word a refusal that
  already happened.
- It judges the blob the model was LOADED FROM, not the typed fields — the lenient load
  ("address":"notanumber" ⇒ 0) is what hides the defect. Same capture-the-source shape
  as S7's `_dataTypeMissingInSource`.

Deliberately-stricter editor rules were surveyed and KEPT, not aligned: AbLegacy's
arrayLength > 256 (reader clamps, but the un-clamped value still sets ArrayDimensions),
FOCAS's unparseable address (#540), MQTT wildcard topics + Sparkplug segment chars, and
Calculation's trigger/50 ms floors. They are now recorded fleet-wide in a table the
tests assert is still accurate.

Behaviour change: Modbus `{}` is now refused. Modbus was the one mapped editor with no
required field, and `{}` is exactly what the modal persists for a config nobody touched
— the driver skips it and it reads BadNodeIdUnknown forever with the deploy green. Its
pinned test asserted the old, weaker behaviour and is rewritten with the rationale.

Falsification: neutering only the Modbus consult turns 14 tests red, all Modbus-scoped;
every #549 enum test stays green.
2026-08-10 01:54:17 -04:00
Joseph Doherty 0e9d977f9a test(raw): write the browse-commit parity guard the mapper's comment cites (#555)
RawBrowseCommitMapper.BuildTagConfig's unknown-driver fallback claimed to be
guarded by RawBrowseCommitMapperParityTests, which did not exist anywhere under
tests/. The claim it made — "every BROWSABLE driver is handled above" — is the
exact claim that stopped being true when SqlDriverBrowser registered (deferment.md
G-6), so the comment was asserting the invariant instead of pinning it.

The guard now exists and enumerates DriverTypeNames.All:

- Browsability's bespoke arm is DERIVED from production, not hand-listed: the test
  runs AddAdminUI() and reads back every registered IDriverBrowser's DriverType —
  the same set BrowserSessionService.CanBrowse indexes. A driver that gains or
  loses a bespoke browser moves the guard with it.
- The universal arm (DiscoveryDriverBrowser -> ITagDiscovery) is NOT derivable from
  the AdminUI assembly: it references driver Contracts/Browser projects, never the
  runtime drivers, and IDriverFactory is composed in the Host. Covered instead by
  requiring every declared driver type to be typed or explicitly exempted with a
  reason (Modbus, Calculation), with a third fact mechanically refuting any
  exemption the derived arm contradicts — the Sql failure mode.

Falsified three ways, each red naming the offender: disabling the Sql branch trips
the derived-arm fact; disabling the MTConnect branch trips the enumeration fact
(the universal-arm half, which no bespoke registration would have caught); adding
Sql to the exemption list trips the contradiction fact.

Comment corrected to state what the test actually asserts, including the residual
trust the universal arm leaves.
2026-08-10 01:38:13 -04:00
Joseph Doherty 1f351250ed merge: #552 — Sql browse-commit states a topByTimestamp row selector from column-type metadata (catalog-order tie-break); no-candidate leaves refused in words at the modal 2026-08-10 01:21:05 -04:00
Joseph Doherty 7498d39e5b fix(sql): browse-commit states a topByTimestamp row selector (#552)
`RawBrowseCommitMapper.BuildSqlTagConfig` emitted a WideRow blob carrying only
table + columnName. A wide-row tag must also say WHICH row it reads, so both
`SqlEquipmentTagParser` (the runtime authority) and `SqlTagConfigModel.Validate`
(the authoring gate) refused it — a browse-committed Sql tag was never readable,
first silently as BadNodeIdUnknown and, since #551 put the gate on the import,
loudly at commit.

`SqlBrowseSession` now states a fourth address field: the table's preferred
date/time-typed column, computed from the columns its attributes call ALREADY
read (no extra catalog round-trip). Candidacy is decided by
`ISqlDialect.MapColumnType` reporting `DriverDataType.DateTime` — never by column
name, which would order a wide-row read by a string column that merely looks like
a timestamp. Multiple candidates tie-break on FIRST IN CATALOG ORDER (every
dialect's column SQL orders by ordinal position), so the pick is stable across
calls and servers; it is a visible, editable default the typed editor round-trips.

No candidate (a table with no date/time column) is an operator-actionable refusal,
not an invented selector: the only remaining selector is a whereColumn/whereValue
pair whose value is data, not schema, so `DescribeUncommittableLeaf` refuses that
leaf by name, names the table, and points at the tag editor.

The session and the mapper now agree via `SqlBrowseAddressFields` constants rather
than two independently spelled string literals — a disagreement there is silent,
and is exactly the shape this defect had.

`RawTagConfigGateTests`' Sql leg flips from "records the gap" to "browse-commit
output passes the gate", with the no-candidate case pinned as its own test.
2026-08-10 01:20:12 -04:00
Joseph Doherty cf2af8a5a2 fix(csv): stop the typed-column merge laundering the TagConfigJson cell (#553)
ModelBackedCsvDriverTagMap.ApplyTypedColumns round-tripped the row's free-form
TagConfigJson cell through a driver model's FromJson/ToJson to fold the typed
columns in. That load is deliberately lenient — it has to be, so a poisoned blob
can be opened and repaired — so a typo'd value under a key the model owns
("dataType":"Intt16") came back out as the model's DEFAULT, before the #551
import gate or any later gate could judge it. The row imported clean and the tag
the operator described was gone. Only keys the model did not own survived to be
judged, which is why RawTagConfigGateTests looked like it covered this.

MTConnect carried the same defect from the export end. It is the one driver whose
blob accepts several spellings per field, and the runtime PREFERS driverDataType
over the dataType key the MtDataType column writes. The export residual carried
that alias (the map owned only the canonical key), so a re-imported row let it
out-rank the very column the operator had just edited — accepted, then silently
ignored at the driver — while the exported cell printed the spelling the driver
was ignoring, or nothing at all.

The fix preserves evidence; it does not move the verdict:

- ApplyTypedColumns writes the base cell's own tokens back over the model's
  serialisation for every key no non-blank typed column overrode. The model still
  stamps defaults for keys the row declares nowhere, so fragment cells compose
  exactly as before.
- CsvTypedColumn gains ReadKeys / OwnedJsonKeys: the full ordered set of spellings
  the RUNTIME reads for that column, mirroring TryFromTagConfig's FirstNonBlank
  pairs. A firing column clears the out-ranking aliases; the export residual drops
  them; the export cell shows the EFFECTIVE value.
- The review grid's override provenance reads the whole owned set, so an
  overridden driverDataType is announced as an overridden dataType would be.

Nothing here decides which values are legal. The verdict stays with
TagConfigValidator on the assembled blob and with IRawTreeService.ImportTagsAsync
behind it — the deliberate reason NOT to follow the issue's own "run the validator
over the pre-merge cell" direction, which would have imposed completeness on a
cell that is legitimately a fragment and false-rejected every typed-column row.

Semantics chosen for the override contradiction: a cell token that a non-blank
column overrides is ACCEPTED with the column winning, and reported by name in
TypedOverrodeFallback. Typed-column-wins is the map's documented contract, the
override is announced rather than silent, and erroring would remove the only way
to repair a poisoned tag through the CSV surface. Every token that reaches the
stored blob is judged; a token the operator overrode is discarded openly.

Falsification: neutering the restore loop + alias handling turns exactly 7 of the
15 new tests red, while RawTagConfigGateTests (#551), RawTagCsvRoundTripTests and
CsvColumnMapReflectionTests all stay green — layering, not replacement.

AdminUI 1248, MTConnect 534, Modbus 373, S7 285, TwinCAT 205 — all green.
2026-08-10 01:18:55 -04:00
Joseph Doherty 333ea48805 merge: #551 — TagConfig gate residuals: accept-gate-first Inspects (7 factories), service-enforced authoring validation (create/update/import), S7 absent-dataType + AbCip members + Modbus stringByteOrder, strict-runtime doc sweep 2026-08-10 00:20:33 -04:00
Joseph Doherty 1ce6e8b107 test(#551): pin browse-commit parity for MTConnect + MQTT, and record the Sql row-selector gap
Verified against the live mapper: every browsable driver's browse-committed
TagConfig passes the gate the commit now runs, EXCEPT Sql — its branch emits a
WideRow blob with no rowSelector, which SqlTagConfigModel and
SqlEquipmentTagParser both refuse. That tag was never readable; the gate only
moves the failure from the deploy gate to the commit. Reported for its own fix
rather than special-cased here.
2026-08-10 00:19:16 -04:00
Joseph Doherty 05b424788f fix(tagconfig): close the four #551 residuals — accept-gate-first Inspect, three authoring rules, CSV/service gate, doc sweep
Gitea #551.

1. CSV import ran no driver-typed config gate. Its typed columns were always
   strictly parsed, but the free-form TagConfigJson column reached the database
   unread, so a CSV could author a tag the driver rejects — one that deploys
   green and reads BadNodeIdUnknown forever. RawTagCsvMapper.Parse now names the
   offending row in the staged review grid, and RawTreeService enforces the same
   gate on CreateTag/UpdateTag/ImportTags: a form cannot be the guarantee (the
   API and any future caller reach none of them, and this repo has no bUnit).
   A rejected import row is an ERROR — the batch inserts nothing and the row is
   named — never a skip.

   Note the brief's premise that manual entry rides ImportTagsAsync is wrong:
   RawManualTagEntryModal commits row-by-row via CreateTagAsync, which is why
   the gate had to land on all three write paths.

2/3. The seven pre-#549 Inspect methods ran a hand-list of DescribeInvalidEnum
   checks, so every rejection cause not on the list was invisible. They are now
   ACCEPT-GATE-FIRST (the MTConnect/Sql/OpcUaClient/Calculation shape): ask the
   driver's own reader for the verdict, then explain the refusal, with a
   catch-all so "the parse rejects but Inspect said nothing" is unreachable.
   That closes S7's absent dataType, AbCip members[], Modbus stringByteOrder and
   the type-dependent guards, plus causes the issue did not name (absent
   region/address/tagPath/symbolPath/topic, TwinCAT Structure, MQTT's Sparkplug
   tuple). FOCAS and MQTT keep advisories about ACCEPTED blobs, so they
   diagnose rather than return empty.

   Authoring half: ModbusTagConfigModel gains stringByteOrder;
   AbCipTagConfigModel asks the new AbCipTagDefinitionFactory.DescribeInvalidMember;
   S7TagConfigModel captures whether the SOURCE blob declared dataType and asks
   S7TagDefinitionFactory.DataTypeKey/DeclaresDataType. One authority per rule.

4. Doc sweep: the six factory Inspect summaries, EquipmentTagConfigInspector's
   class remarks and AdminOperationsActor's comment all claimed invalid enums are
   "silently defaulted by the lenient runtime" — false since R2-11 Phase C made
   the runtime reads strict. They describe rejections now.
2026-08-10 00:08:06 -04:00
Joseph Doherty 8971861b7c fix(adminui): MTConnect editor must read driverDataType at the runtime's precedence and drop the alias on save (#550)
MTConnectTagDefinitionFactory.TryFromTagConfig resolves the coercion type as
FirstNonBlank(blob.DriverDataType, blob.DataType) — driverDataType OUT-RANKS
dataType — while MTConnectTagConfigModel read and wrote dataType alone. That
broke in both directions at once:

  * a blob carrying "driverDataType": "Strng" was accepted at authoring while
    the runtime rejected the tag (the residual slice of #549), and
  * a VALID driverDataType silently overrode whatever type the editor displayed
    and saved, so the editor showed a lie and a save RETYPED the tag.

Both halves land together, mirroring the existing IdKeys pattern:

  * FromJson reads DataTypeKeys = [driverDataType, dataType] in the runtime's
    precedence, with the runtime's own per-key semantics — absent/JSON-null and
    present-but-blank fall through, a non-string token stops the walk (the
    runtime deserialise throws JsonException on it and rejects the whole tag),
    and the raw TOKEN is captured so Validate() judges what the driver judges.
  * ToJson drops every non-canonical DataTypeKeys entry and writes dataType as
    the enum NAME, so the alias can never out-rank the key the editor writes on
    the next load.
  * Validate() now names the offending spelling rather than always saying
    "dataType".

Doing only one half silently retypes existing tags on their next save; the
falsification runs recorded in the PR confirm each half-fix reddens a distinct
test.
2026-08-09 23:44:14 -04:00
Joseph Doherty 3a70a4e6ea merge: #549 — authoring never accepts a TagConfig enum the runtime rejects (6 models, one shared authority) 2026-08-09 22:15:46 -04:00
Joseph Doherty a3c0ec037f fix(adminui): authoring must not accept a TagConfig enum the runtime rejects (#549)
MTConnectTagConfigModel read `dataType` with TagConfigJson.GetEnum, which falls
back to String on ANY unrecognised value. A misspelled name ("Strng") from a
hand-authored blob, a CSV import or the API was therefore accepted at authoring
and silently rewritten, while the driver's strict parse rejected it and the tag
died with BadNodeIdUnknown. Found by the G-7 parity tests' falsifiability
control, which had to use the digits-only shape to have a case that failed.

The rule is not restated in the AdminUI. MTConnectTagDefinitionFactory exposes
its parse as `IsAcceptedDataTypeName`, documented as the one authority the
driver, the deploy gate and the authoring model all consult; the model's
Validate() asks it about the raw value the blob carries. The old digits-only
message is NOT retained as a special case: the runtime draws no distinction
between a bare number and a typo — one predicate, one Inspect warning — so a
second message here would be a second statement of a rule this model does not
own. The raw value is captured as the JSON TOKEN, because the runtime
deserialises the key into a `string?` DTO field and an unquoted number throws
there too.

The survey found the same asymmetry at six more editors, contrary to the
assumption that those runtimes silently default: R2-11 Phase C moved every
driver's TagConfig enum read to TagConfigJson.TryReadEnumStrict, which REJECTS
the tag on a present-but-invalid string, while the editors kept loading them
with a silent fallback. Modbus (region/dataType/byteOrder), S7, AbCip, AbLegacy,
TwinCAT and FOCAS now check their enums in Validate() through the runtime's own
TagConfigJson.DescribeInvalidEnumText — added alongside a public
ClassifyEnumText that TryReadEnum now delegates to, so the JSON-token door and
the string door reach one implementation. Mqtt and Sql already carried
equivalent strict checks and are untouched.

Care taken NOT to become stricter than the runtime: a present-but-non-string
token stays accepted for those six (TryReadEnum calls it absent), as does an
absent key, each pinned by a test.

Also adds a direct ProjectReference to Core.Abstractions from the AdminUI — the
save gate now leans on a type it was consuming only transitively.
2026-08-09 22:08:42 -04:00
Joseph Doherty b4f8cb8de7 refactor(opcuaclient): move NamespaceMap to a .Session leaf so Contracts is dependency-light
G-7 wired OpcUaClientTagDefinitionFactory.Inspect into the deploy-time TagConfig
gate, which gave ControlPlane a ProjectReference to
Driver.OpcUaClient.Contracts — and with it, transitively, the whole OPC UA client
stack (5 OPCFoundation packages) into every host that loads the control plane.

NamespaceMap was the only reason Contracts carried
OPCFoundation.NetStandard.Opc.Ua.Client: its entire public surface is
ISession/NamespaceTable/NodeId-typed. It moves to a new leaf project,
ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient.Session, referenced by the runtime .Driver
and by .Browser. Contracts is left with Core.Abstractions and NOTHING else —
the same shape as Calculation.Contracts.

The namespace stays ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient, so no consumer's
`using` changed. The .Session -> .Contracts direction is deliberate: the blob
read NamespaceMap needs is OpcUaClientTagDefinitionFactory.TryReadNodeId, the
one authority it shares with the deploy gate, and that must stay in the
dependency-light half.

Why a new project rather than folding NamespaceMap into the runtime .Driver and
having .Browser reference it (the Driver.Mqtt.Browser #512-style deliberate
exception): the AdminUI project-references .Browser and NOT .Driver, so that
shape would pull the OpcUaClient driver runtime — plus Core,
Opc.Ua.Configuration and Secrets.Abstractions — into the AdminUI's build/deploy
graph. That is exactly the violation #512 spent two extractions removing from
Mqtt.Browser; re-introducing it to save one csproj is a bad trade.

Guard: ContractsIsDependencyLightTests (Driver.OpcUaClient.Tests) asserts the
Contracts manifest names no Opc.Ua* assembly, plus a counterpart asserting
.Session does. An ABSENCE assertion is sound on the manifest where a presence
one is not — the compiler elides an unused reference, but it MUST emit one the
moment Opc.Ua-typed code is added. Falsified by temporarily re-adding the
package plus an Opc.Ua.NodeId-typed member: red on Opc.Ua.Types, green again on
removal.

Evidence — `dotnet list ControlPlane package --include-transitive | grep -i opc`:
  before: OPCFoundation.NetStandard.Opc.Ua.{Client,Configuration,Core,
          Security.Certificates,Types} 1.5.378.106
  after:  none (and 0 Opc.Ua*.dll in ControlPlane's output directory)
2026-08-09 21:56:29 -04:00
Joseph Doherty 0695f682c2 merge: G-7 closed — Contracts-side TagConfig Inspect for Sql/MTConnect/Calculation/OpcUaClient wired into the deploy gate 2026-08-09 21:16:16 -04:00
Joseph Doherty 1469fbb4d1 feat(deploy): wire the four G-7 inspectors into the deploy-time TagConfig gate
Adds the Sql / MTConnect / Calculation / OpcUaClient Contracts ProjectReferences to
ControlPlane and their entries to EquipmentTagConfigInspector, closing the G-7 asymmetry: the
deploy gate now checks every driver the AdminUI checks. Galaxy is the sole remaining unmapped
type and is so by design — its dotted tag_name.AttributeName reference has no typed shape, and
the AdminUI has no typed editor for it either, so the two gates agree.

Adding the ProjectReference is what makes EquipmentTagConfigInspectorCoverageTests demand a map
entry (its sweep scans the output directory, so an unreferenced Contracts assembly is invisible
to it). Falsified: deleting the Sql entry fails
Every_driver_shipping_an_Inspect_is_wired_into_the_dispatch_map with
["SqlTagDefinitionFactory"]; restored.

Tests: three cases per driver in EquipmentTagConfigInspectorTests (canonical valid config warns
nothing / present-but-invalid field draws a warning naming it / broken JSON warns without
throwing), plus a Calculation control pinning that the two shapes the runtime accepts and the
editor refuses draw nothing. OpcUaClient moved out of the unmapped-driver theory.

New TagConfigAuthoringDeployParityTests (in AdminUI.Tests, the only suite that sees both gates)
pins the direction that matters: a config the AdminUI model's own ToJson produces and Validate
accepts draws no deploy warning. Its falsifiability control — the same driver types warning
about a blob the editor refuses — caught a pre-existing, unrelated authoring-side gap:
MTConnectTagConfigModel reads dataType leniently, so a misspelled name loads as String and
saves clean while the strict runtime rejects it. Left alone (rewriting the editors is out of
scope); the control uses the digits-only shape both gates refuse, and the case is documented
inline.
2026-08-09 21:14:49 -04:00
Joseph Doherty 0739f4b9a4 merge: RawBrowseModal post-await staleness guard (deferment §0.1 race ported from the 2026-08-05 sibling fix) 2026-08-09 21:08:00 -04:00
Joseph Doherty 87637e4e2c fix(adminui): guard RawBrowseModal's resolve against a superseded open
Blazor does not serialize OnParametersSetAsync against its own outstanding
task, and the modal's `_open` bool cannot tell two opens apart. ResetAndResolveAsync
awaits LoadMergedProbeConfigAsync and ResolveGroupContextAsync and then wrote
_driverType/_mergedConfig/_effectiveDeviceId/_groupPrefix/_canBrowse/_disabledReason
with no staleness re-check, so a close-reopen onto another device let the first
open's late continuation install its device's browse context under the displayed
modal — "Connect & browse" would silently dial the wrong controller and the commit
would land under the wrong tag-group.

Ports the per-open `_openGeneration` counter proven in the two sibling modals
(RawManualTagEntryModal, RawTagModal, 2026-08-05) to every post-await write here:
after both awaits, in the catch's error banner, and in the finally. The finally is
the one departure from the sibling shape and it is load-bearing — this modal resolves
inside a try/finally, so a stale `return` still runs the tail and would drop the LIVE
open's spinner mid-resolve.

Pinned by four RawBrowseModalStaleOpenTests facts, each observed red before the guard
and each re-falsified afterwards by reverting only its own guard. The modal calls
StateHasChanged on the open path, which throws without a render handle, so the test
attaches an inert Renderer subclass (file-local BL0006 pragma); [Parameter]s are set
by reflection per the BL0005 convention.

AdminUI suite 1117/1117 green.
2026-08-09 21:07:07 -04:00
Joseph Doherty 205cc4a4a3 feat(galaxy): per-code OPC UA mapping for the MxStatusDetail vocabulary
Follow-up to 20a816db: mxaccessgw published the full MxStatusDetail enum
(gateway.md @ 75c71ad, "MxStatus Detail Vocabulary", lifted from
Interop.aaMxDataConsumer.MxStatusDetail), confirming the live-captured codes
(1007 = MX_E_NotWriteable, 1008 = MX_E_WriteAccessDenied). FromCategory now
maps the write-relevant band per code before falling back to the category
bucket: 1004 -> BadOutOfRange, 1005 -> BadTypeMismatch, 1006 -> BadNotReadable,
1007 -> BadNotWritable, 1008/1012/1013/1016/1017 -> BadUserAccessDenied,
1010/1011 (initializing, transient) -> BadOutOfService. 8000
(MX_E_AutomationObjectSpecificError) deliberately stays category-level — the
object supplies its own semantics. Codes <= 0xFF are value-ambiguous with the
OPC DA quality-byte space and keep the quality path (still Bad-family).

Four new named constants, all validated by StatusCodeParityTests against the
pinned SDK. Live refusal smoke re-run green (read-only refusal now surfaces
BadNotWritable instead of generic Bad).
2026-08-09 20:16:29 -04:00
Joseph Doherty 20a816dbf4 feat(galaxy): consume the gateway's correlated write statuses; close archreview 06/S-1
The mxaccessgw OnWriteComplete correlation is live (server b948e69, worker
53f69cd — all four unary write kinds), so every write reply's statuses[0] now
carries the real COM commit outcome. Live-gating the cutover on windev found
and fixed three defects:

- StatusCodeMap.FromMxStatus truncated the correlated failure row's MxStatus
  detail code to a byte (1007 & 0xFF = 239 -> OPC DA Good band), mapping a
  REFUSED write to Good. New invariant: a row that is not IsSuccess() never
  maps Good — details > 0xFF (and contradictory Good-band substatuses) route
  by category (SECURITY_ERROR -> BadUserAccessDenied, named const covered by
  StatusCodeParityTests; COMMUNICATION/CONFIGURATION keep their codes).

- The borrow-from-subscription-registry write optimization could never commit:
  a subscription handle is plain-advised, and MXAccess refuses both the
  no-login write through it (SECURITY_ERROR detail 1008, live-captured) and
  the supervisory advise upgrade (E_INVALIDARG) — one advise per HANDLE, not
  per attribute. Removed: writer subscribedHandleSource ctor param + borrow
  branch, GalaxyDriver wiring, SubscriptionRegistry.TryResolveItemHandle +
  its forward index and test file. The writer always AddItems its own
  supervisory-advised handle, which commits fine while the same attribute is
  subscribed (live-proven; pinned by the new write-while-subscribed smoke).

- (gateway-side, fixed there) the correlation initially covered WriteSecured
  only, while the dominant no-login path emits plain Write.

Live gate, all legs PASSED against windev: happy write Good off a confirmed
status row with galaxy.writes.unconfirmed + advise_failed both FLAT; read-only
refusal surfaces Bad-family (the #5 node-revert input Galaxy could never
produce before); WriteCompletionWaitMilliseconds=0 control -> provisional Good
+ metered unconfirmed (override removed after, restoration re-verified). New
env-gated smokes: Live_correlated_write_statuses_confirm_commit_and_surface_refusal,
Live_write_to_subscribed_tag_commits_via_own_handle (replaces the borrow
smoke), GatewayGalaxyWriteMeterLiveTests (run filtered — meters are
process-wide).
2026-08-09 20:11:55 -04:00
Joseph Doherty dac7e1885d feat(resilience): route IDriver.InitializeAsync through the capability invoker (R2-10 T10 closed)
The connect path was the one capability call the resilience pipeline never
saw, so a driver that could not connect contributed zero breaker input and
the /hosts resilience panel read 'All targets healthy' against a dead
endpoint. InitializeAsync now routes through the invoker as
DriverCapability.Initialize, keyed on the driver-instance id.

- No pipeline retry: the actor's RetryConnect timer is the retry loop
  (parser forces retryCount overrides to 0, same funnel as write-shaped).
- Breaker threshold 2, not the Read-sized 5: the breaker samples 30 s and
  the reconnect timer fires every 10 s, so at most three attempts fit one
  window — threshold 5 could never open. Pinned by its own test.
- An open breaker fast-fails into the same InitializeFailed path as a real
  connect failure; the 15 s break window costs at most one extra tick.
  The best-effort teardown ShutdownAsync stays unwrapped.
- Companion fix: DriverCapabilityInvokerFactory.Create now invalidates the
  instance's tracker snapshots with its pipelines — a respawn during an
  outage discarded the only breaker whose OnClosed could clear the OPEN
  flag, stranding a false 'Breaker OPEN' chip forever.

Live gate PASSED on docker-dev (image symbol-verified per container):
rtu-gate against dead 10.100.0.35:5021 opened its Initialize breaker on
both centrals with the red 'BREAKER OPEN' chip on /hosts; a socat
5021→5020 forwarder recovered it (both breakers closed within 1 s, panel
back to 'All targets healthy'); healthy MAIN-modbus recorded zero breaker
events. Full suite 50/50 green. Evidence:
docs/plans/2026-08-07-adminui-followups-and-live-gates.md §7.
2026-08-08 05:45:08 -04:00
Joseph Doherty 1e02661598 chore(gates): close adminui-followups by audit; R2-03 T11/T12 + reconfigure Task 3 PASSED, R2-10 re-diagnosed
The two items deferment.md §0.1 named as the remaining untracked engineering.

adminui-followups (19 pending / 0 completed) — CLOSED by the overlap audit the plan
itself asks for first, with no code written. All 19 tasks are shipped, superseded by
v3, or moot. WS1's premise had also expired: it assumed driver-embedded tag lists in
DriverConfig are the runtime source of truth, which v3 ended (the artifact populates
RawTags). Its capability shipped in the v3 shape — TagConfigEditorMap + DeviceFormMap,
both verified reachable from RawTagModal/DeviceModal rather than merely present.

Live gates on docker-dev (image rebuilt: the rig was running a build 3 h older than the
last code commit; parity asserted per container plus a positive check that the symbols
under test are in the shipped DLLs):

- R2-03 T11 PASSED — build 0 errors, Runtime.Tests 555/555, RoslynVirtualTagEvaluator 20/20.
- R2-03 T12 PASSED — VT 42 -> 0x80020000 -> 42, staged WITHOUT a deployment (a Modbus
  register flipped on the fixture) so the VT child survived; a deploy-driven trip creates
  a fresh child with no last value, which is correct-by-design and masked the result twice.
  P7 confirmed: two byte-identical redeploys, zero disturbance.
- driver-reconfigure Task 3 PASSED — a faulted driver adopted a corrected config and
  connected with the node's startedAt unchanged and RestartCount=0.
- R2-10 T10 still OPEN, but the recorded cause was wrong. Not ConnectionBackoff
  throttling (the breaker opens on 2 failures / 30 s): the dead-endpoint failure mode
  never enters the resilience pipeline. IDriver.InitializeAsync is not invoker-wrapped
  (DriverInstanceActor.cs:707) and ModbusDriver swallows per-tag failures in BOTH
  directions, so even the plan's fallback trigger cannot work. Live-proven: a driver
  timing out every read against a blackhole reported ConsecutiveFailures=0 while the
  panel read "All targets healthy."

Finding from T12: the Bad publish's documented "carrying the last-known value" is
unobservable by any client — subscription and a raw Read service call both return NULL.
The actor is correct; every existing failure assertion checked StatusCode alone, so the
value half was asserted nowhere. Adds
VirtualTagActorTests.The_Bad_result_carries_the_last_known_value, which proves the actor
emits it. The documentation is what overstates.
2026-08-07 06:28:22 -04:00
Joseph Doherty 8b10d32728 fix(focas): disambiguate duplicate sibling axis/spindle names in the fixed tree (#548)
A CNC can report duplicate sibling names — the wonder Makino returns two
axes both called AA — which made the Axes/ subtree untrustworthy: the
browser offered two identical folders the commit gate had to refuse, and
the poll loop's name-keyed snapshot cache let the second axis silently
overwrite the first. Spindles and servo loads had the same collision in
their own keying, plus a resolve-to-first-match on the spindle read path.

Scheme: every member of a collision set gets a 1-based occurrence-ordinal
suffix in slot order (AA_1, AA_2); unique names stay bare. Chosen over the
alternatives deliberately:

- Names, not slot numbers, stay the primary identity — the segment map is
  re-derived from the live device each session, so a name-keyed path
  follows the physical axis across config changes, where a slot-qualified
  path would silently rebind on any axis-list shift and rename every axis
  on every machine for one pathological CNC.
- The WHOLE collision set is suffixed: bare AA ceases to exist when
  ambiguous, so a tag authored against it reads BadNodeIdUnknown rather
  than one arbitrary axis's data — the #534/#540 silent-wrongness class.
- Occurrence ordinal, not absolute slot: inserting/removing an unrelated
  axis never renames an existing duplicate pair. If the collision-set
  membership itself changes, segments change on the next browse and stale
  authored segments read Bad, never another axis's data.

One pure helper (FixedTreeNames.Disambiguate, collision-proof against
genuine names by suffix escalation) feeds FocasFixedTreeCache.AxisSegments
/ SpindleSegments, and the emitter, axis snapshot keys, servo-load keys
(cnc_rdsvmeter answers in slot order, so the k-th AA load belongs to the
k-th AA axis) and the spindle read resolution all consume those — they can
no longer disagree. The nameless-spindle S{n} fallback applies before
disambiguation so a fallback name colliding with a real one is handled
like any other duplicate.

Tests are red-first on the pre-fix driver (all five driver-level tests
fail on master's code): browse emits AA_1/AA_2 and no bare AA, each
duplicate reads its own position and servo load, duplicate spindles
resolve per slot, bare AA reads Bad. The wire half runs live against
focas-mock (duplicate names survive the managed wire parse and publish as
suffixed segments); the mock's dynamic store is name-keyed so the
distinct-values half stays with the offline tests. FOCAS 327/327,
integration 11/11, FOCAS.Cli 52, AdminUI 1113, ControlPlane 231.

Closes #548.

Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
2026-08-06 21:09:05 -04:00
Joseph Doherty 97a837c147 fix(abcip): controller browse honours the authored EtherNet/IP port (#539)
The two discovery-path libplctag tags (@tags symbol-list enumerator, @udt
template reader) still passed the bare Gateway host, so a browse against a
device authored on a non-default port silently browsed whatever answers on
44818 — #534's defect surviving in its discovery half. Both sites now consume
AbCipTagCreateParams.LibplctagGateway, with the Tag construction extracted
into internal static builders so the seam is unit-assertable (the #534 tests
pinned the property's composition but nothing pinned each site's consumption,
which is exactly how these two survived).

New guard: LibplctagGatewayConsumptionGuardTests scans both AB drivers'
sources and fails on any libplctag Tag built from the bare Gateway, so a
future call site cannot reintroduce the silent 44818 redirect.

Live-gated against the fixture host: browse of ab://10.100.0.35:44818
returns the nine-tag symbol table; browse of ab://10.100.0.35:44999 (nothing
listening — the issue's exact repro) now fails ErrorTimeout where it
previously returned the 44818 fixture's table.

Closes #539.

Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
2026-08-06 20:42:40 -04:00
Joseph Doherty 9420f8efff Merge fix/issue-546-panel: wire DriverStatusPanel into /hosts driver rows (#546)
v2-ci / build (push) Successful in 5m22s
v2-ci / unit-tests (push) Failing after 17m32s
Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
2026-08-06 17:28:48 -04:00
Joseph Doherty d01b717eb9 Merge fix/issue-542-fleetstatus: delete the dead fleet-status chain (#542)
Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
2026-08-06 17:28:48 -04:00
Joseph Doherty f1c188114b refactor(fleet): #542 delete the dead fleet-status chain (broadcaster, SignalR bridge, hub, messages)
#542 filed FleetStatusBroadcaster as blind to site nodes since the Phase 6 per-cluster mesh
split: it derives "the fleet" from central's own Akka gossip ring, which after the split is
just central's own pair. Scoping the cross-mesh rewrite found the deeper truth — the whole
chain is dead end to end, so this deletes it rather than reviving it.

  - Zero consumers. FleetStatusBroadcaster published FleetStatusChanged on the DPS
    "fleet-status" topic; FleetStatusSignalRBridge forwarded it to FleetStatusHub
    ("/hubs/fleet-status"); nothing anywhere connected. The AdminUI bans self-connecting
    HubConnections, no browser JS subscribes, and /fleet (Fleet.razor) reads
    NodeDeploymentState from the ConfigDb plus IClusterRoleInfo on a 5 s poll instead.
  - Its second input never existed. DriverHostStatusHeartbeat had no production sender —
    only the broadcaster's own test told it — so CurrentRevision was always null and the
    30 s staleness -> Degraded flip could never fire.
  - Post-Phase-6 DPS is pair-local, so even the central-only view it did produce was an
    accident of topology rather than a design.

The fleet visibility that actually works is unchanged and already cross-mesh-correct:
/fleet over NodeDeploymentState, and the four Phase 5 per-node telemetry dials.

Precedent for deleting inert machinery rather than activating it: #522 (driver stability
tiers), #507 (discovered-node injection), #525 (GetMemoryFootprint).

Deleted: FleetStatusBroadcaster (+ its nested DriverHostStatusHeartbeat), its admin
singleton registration and FleetStatusBroadcasterKey, FleetStatusSignalRBridge and its
key, FleetStatusHub and its route mapping, and the FleetStatusChanged / FleetNodeStatus /
FleetNodeHealth messages. Both Fleet/ directories survive — ControlPlane keeps
ClusterNodeAddressReconciler, Commons keeps GetDiagnostics. Docs swept where they claimed
a fleet-status channel exists (Telemetry.md's Phase 5 non-migrated channels,
Configuration.md, CLAUDE.md); completed-program plan docs under docs/plans and docs/v2 are
left as the historical record they are.

Build 0 errors, 868 warnings — byte-identical to master's rebuild baseline.
ControlPlane.Tests 231/231, AdminUI.Tests 1109/1109.

Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
2026-08-06 17:21:30 -04:00
Joseph Doherty d33e4e20b5 feat(adminui): #546 wire DriverStatusPanel into /hosts driver rows (collapsed expander)
DriverStatusPanel was orphaned — zero references repo-wide — so the Restart and
Reconnect driver commands had NO reachable UI at all, despite working end to end
over the new gRPC mesh transport. Nothing failed to build, test or deploy while
that was true, which is why it went unnoticed.

The panel is now reachable per driver row on /hosts, behind a per-row "Controls"
expander that is collapsed by default: the table stays scannable, and only the
opened panels hold snapshot-store subscriptions. Expansion state is a HashSet
keyed by DriverInstanceId held on the page, so it survives the 5 s refresh that
replaces every row record. Both rows are @key'd by instance id so the panel —
which binds its DriverInstanceId once in OnInitializedAsync — can never be diffed
onto a different driver.

The panel's Enabled parameter is fed from real config rather than defaulted:
HostsDriverInstanceInfo/HostsDriverRow now carry DriverInstance.Enabled, which
LoadConfigAsync already had in hand. A snapshot with no matching configured
instance is treated as enabled — the row exists only because live health arrived,
so "Disabled — not deployed" would contradict the same row.

The expander is visible to every AuthenticatedRead viewer; the panel self-gates
only its Reconnect/Restart buttons on DriverOperator.

A source-scan pin (HostsPanelWiringTests) asserts /hosts still renders the panel
and still binds it to the row's own driver, cluster and enabled state — removing
the tag would silently restore the orphaned state.

Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
2026-08-06 17:18:37 -04:00