Cause: the client-side PerEndpointConnectTimeout (3 s), not opc-plc. The
validate:null case is the first test the assembly runs, so it pays the
cold-process cost of the first Basic256Sha256 connect: loading the fresh
throwaway certificate, validating the server's, and the asymmetric handshake.
In the G2 full-solution run that local work used up the budget. The opc-plc
log at 13:13:50-53Z shows the discovery channel closing at 50.709, then nothing
from the client for 3 s, then OpenSecureChannel answered at 53.775 and the
client closing the channel 48 ms later. The SDK reports a wait cancelled by
that budget as BadRequestInterrupted. opc-plc auto-accepted the certificate
(--aa, "Trusting certificate ... command line option") with no reject and no
store round-trip.
- Driver: a per-endpoint budget expiry now surfaces as TimeoutException naming
PerEndpointConnectTimeout instead of BadRequestInterrupted or a bare
TaskCanceledException. There is no behaviour change. Unit test added
against a silent TCP listener.
- Test: the ServerHostNameValidationTests secure options use a 15 s budget,
the same as the browser integration tests' 10 s. Connect latency is not
what these tests check.
- docs/drivers/OpcUaClient.md: documents what the budget covers.
The phase-6-*.ps1 scripts checked v2 Phase 6 code that later commits deliberately
deleted (76310b88 v1 Server/Admin, #522, #524, LiteDB cache, v3 migration squash):
56/56 failures were retired files, so they could not pass. Owner retired G1; G2
plus the per-area suites cover the invariants. phase-7-compliance.ps1 is untouched.
Two service-env entries per node (Mode=Warm, PeerApplicationUris__0), pair stopped and
started together. Gates: 250/90, RedundancySupport Warm, standby BadOutOfService,
LocalDb sync, canary Good on the Primary; standby Write could only show BadNotWritable
(QA tags are read-only). ScadaBridge WarmCanary moved off the Standby by ServiceLevel in
0.1 s (connect-time preference); graceful Primary stop still took the 66 s connectivity
path (ScadaBridge#141). End state: Warm, vq04 Primary.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
On QA (76e73e7d deploy) Invoke-OtOpcUaInstallSwap.ps1's first Move-Item of
app\ failed "file in use" right after the service reported Stopped: SCM
reports Stopped while the host is still exiting (e.g. a log file under
InstallRoot still open).
- After the stop, wait (bounded, -ProcessExitTimeoutSeconds, default 60)
until the service's host process (PID + start time captured before the
stop) and every process imaged under InstallRoot have exited; otherwise
throw naming them, with nothing moved.
- The renames use [IO.Directory]::Move instead of Move-Item. On windev,
PowerShell 7's Move-Item falls back to an item-by-item move when the
rename fails because a file under the folder is open, and leaves a partial
PreviousInstall tree behind (a retry then nests into it).
- The first rename is retried for at most -MoveRetrySeconds (default 10)
while it fails because something under InstallRoot is open (a backstop
for a holder whose image is outside InstallRoot).
- -Verify/-Reapply/-Scope semantics unchanged.
Tests: dry-run harness gains fake-process-list tests for the wait and the
retry plus AST order checks (145 passed); the Windows harness gains three
real cases (holder past the budget, holder released 2 s into the wait,
holder outside InstallRoot) - 77/0 on pwsh 7 and Windows PowerShell 5.1 on
windev; with the wait removed the first two fail.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi