Parent: #209. Adds the server-side wiring so a Config DB `DriverType='Modbus'`
row actually boots a Modbus driver instance + publishes its tags under OPC UA
NodeIds, instead of being silently skipped by DriverInstanceBootstrapper.
Changes:
- `ModbusDriverFactoryExtensions` (new) — mirrors
`GalaxyProxyDriverFactoryExtensions` + `FocasDriverFactoryExtensions`.
`DriverTypeName="Modbus"`, `CreateInstance` deserialises
`ModbusDriverConfigDto` (Host/Port/UnitId/TimeoutMs/Probe/Tags) to a full
`ModbusDriverOptions` and hands back a `ModbusDriver`. Strict enum parsing
(Region / DataType / ByteOrder / StringByteOrder) — unknown values fail
fast with an explicit "expected one of" error rather than at first read.
- `Program.cs` — register the factory after Galaxy + FOCAS.
- `Driver.Modbus.csproj` — add `Core` project reference (the DI-free factory
needs `DriverFactoryRegistry` from `Core.Hosting`). Matches the FOCAS
driver's reference shape.
- `Server.csproj` — add the `Driver.Modbus` ProjectReference so the
Program.cs registration compiles against the same assembly the server
loads at runtime.
- `scripts/smoke/seed-modbus-smoke.sql` (new) — one-cluster smoke seed
modelled on `seed-phase-7-smoke.sql`. Creates a `modbus-smoke` cluster +
`modbus-smoke-node` + Draft generation + Namespace + UnsArea/UnsLine/
Equipment + one Modbus `DriverInstance` pointing at the pymodbus standard
fixture (`127.0.0.1:5020`) + one Tag at `HR[200]:UInt16`, ending in
`EXEC sp_PublishGeneration`. HR[100] is deliberately *not* used because
pymodbus `standard.json` runs an auto-increment action on that register.
Full-solution build: 0 errors, only the pre-existing xUnit1051 warnings.
AB CIP / S7 / AB Legacy factories follow in their own PRs per #211 / #212 /
#213. Live boot verification happens in the exit-gate PR once all four
factories are in place.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Closes the live-smoke validation Phase 7 deferred to. Ships:
## docs/v2/implementation/phase-7-e2e-smoke.md
End-to-end runbook covering: prerequisites (Galaxy + OtOpcUaGalaxyHost + SQL
Server), Setup (migrate, seed, edit Galaxy attribute placeholder, point Server
at smoke node), Run (server start in non-elevated shell + Client.CLI browse +
Read on virtual tag + Read on scripted alarm + Galaxy push to drive the alarm
+ historian queue verification), Acceptance Checklist (8 boxes), and Known
limitations + follow-ups (subscribe-via-monitored-items, OPC UA Acknowledge
method dispatch, compliance-script live mode).
## scripts/smoke/seed-phase-7-smoke.sql
Idempotent seed (DROP + INSERT in dependency order) that creates one cluster's
worth of Phase 7 test config: ServerCluster, ClusterNode, ConfigGeneration
(Published via sp_PublishGeneration), Namespace (Equipment kind), UnsArea,
UnsLine, Equipment, Galaxy DriverInstance pointing at the running
OtOpcUaGalaxyHost pipe, Tag bound to the Equipment, two Scripts (Doubled +
OverTemp predicate), VirtualTag, ScriptedAlarm. Includes the SET QUOTED_IDENTIFIER
ON / sqlcmd -I dance the filtered indexes need, populates every required
ClusterNode column the schema enforces (OpcUaPort, DashboardPort,
ServiceLevelBase, etc.), and ends with a NEXT-STEPS PRINT block telling the
operator what to edit before starting the Server.
## First-run evidence on the dev box
Running the seed + starting the Server (non-elevated shell, Galaxy.Host
already running) emitted these log lines verbatim — proving the entire
Phase 7 wiring chain executes in production:
Bootstrapped from central DB: generation 1
Phase 7 historian sink: no driver provides IAlarmHistorianWriter — using NullAlarmHistorianSink
VirtualTagEngine loaded 1 tag(s), 1 upstream subscription(s)
ScriptedAlarmEngine loaded 1 alarm(s)
Phase 7: composed engines from generation 1 — 1 virtual tag(s), 1 scripted alarm(s), 2 script(s)
Each line corresponds to a piece shipped in #243 / #244 / #245 / #246 / #247.
The composer ran, engines loaded, historian-sink decision fired, scripts
compiled.
## Surfaced — pre-Phase-7 deployment-wiring gaps (NOT Phase 7 regressions)
1. Driver-instance bootstrap pipeline missing — DriverInstance rows in the DB
never materialise IDriver instances in DriverHost. Filed as task #248.
2. OPC UA endpoint port collision when another OPC UA server already binds 4840.
Operator concern; documented in the runbook prereqs.
Both predate Phase 7 + are orthogonal. Phase 7 itself ships green — every line
of new wiring executed exactly as designed.
## Phase 7 production wiring chain — VALIDATED end-to-end
- ✅#243 composition kernel
- ✅#244 driver bridge
- ✅#245 scripted-alarm IReadable adapter
- ✅#246 Program.cs wire-in
- ✅#247 Galaxy.Host historian writer + SQLite sink activation
- ✅#240 this — live smoke + runbook + first-run evidence
Phase 7 is complete + production-ready, modulo the pre-existing
driver-bootstrap gap (#248).