Booted the server against the Modbus seed end-to-end to exercise the
factory wiring shipped in #216 + #217. Surfaced two real issues with
the seeds themselves; fixed both:
1. **Missing ClusterNodeCredential.** `sp_GetCurrentGenerationForCluster`
enforces `ClusterNodeCredential.Value = SUSER_SNAME()` and aborts
with `RAISERROR('Unauthorized: caller sa is not bound to NodeId')`.
All four seed scripts now insert the binding row alongside the
ClusterNode row. Without this, the server fails bootstrap with
`BootstrapException: Central DB unreachable and no local cache
available` (the Unauthorized error gets swallowed on top of the
HTTP fallback path).
2. **Config cache gitignore.** Running the server from the repo root
writes `config_cache.db` + `config_cache-log.db` next to the cwd,
outside the existing `src/.../Server/config_cache.db` pattern. Add
a `config_cache*.db` pattern so any future run location is covered.
## Verified live against Modbus
Booted server against `seed-modbus-smoke.sql` → pymodbus standard
fixture → ran `scripts/e2e/test-modbus.ps1 -BridgeNodeId "ns=2;s=HR200"`:
=== Modbus e2e summary: 4/5 passed ===
[PASS] Probe
[PASS] Driver loopback
[PASS] Server bridge (driver → server → client)
[FAIL] OPC UA write bridge (0x801F0000)
[PASS] Subscribe sees change
The forward direction + subscription delivery are proven working through
the server. The reverse-write failure is a seed-or-ACL issue — server
log shows no exception on the write path, so the client-side status is
coming from the stack's type/ACL guards. Tracking as a follow-up issue
so the remaining three factory wirings can be smoke-booted against the
same pattern.
Note for future runs: two stale v1 `ZB.MOM.WW.LmxOpcUa.Host.exe`
processes from `C:\publish\lmxopcua\instance{1,2}\` squat on ports
4840 + 4841 on this dev box; kill them first or bump the seed's
DashboardPort.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
The driver-layer integration tests confirm the driver sees the PLC, and
the Client.CLI tests confirm the client sees the server. Nothing glued
them end-to-end until this PR.
- scripts/e2e/_common.ps1: shared helpers — CLI invocation (published-
binary OR `dotnet run` fallback), Test-Probe / Test-DriverLoopback /
Test-ServerBridge (all return @{Passed;Reason} hashtables).
- scripts/e2e/test-<modbus|abcip|ablegacy|s7|focas|twincat>.ps1: per-
driver three-stage script (probe → driver-loopback → server-bridge).
AB Legacy / FOCAS / TwinCAT are gated behind *_TRUST_WIRE env vars
since they need real hardware (#222) or a licensed runtime (#221).
- scripts/e2e/test-phase7-virtualtags.ps1: writes a Modbus HR, reads
the server-side VirtualTag (VT = input * 2) back via OPC UA, triggers
+ clears a scripted alarm. Exercises the Phase 7 CachedTagUpstreamSource
+ ScriptedAlarmEngine path.
- scripts/e2e/test-all.ps1: reads e2e-config.json sidecar, runs each
present driver, prints a FINAL MATRIX (PASS/FAIL/SKIP). Missing
sections SKIP rather than fail hard.
- scripts/e2e/e2e-config.sample.json: commented sample — each dev's
NodeIds are local-seed-specific so e2e-config.json is .gitignore-d.
- scripts/e2e/README.md: full walkthrough — prereqs, three-stage design,
env-var gates, expected matrix, why this is separate from `dotnet test`.
Tasks #249-#251 shipped Modbus/AbCip/AbLegacy/S7/TwinCAT CLIs but left
FOCAS out. Since test-focas.ps1 needs it, the 6th CLI ships here:
- src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli: probe/read/write/subscribe
commands, AssemblyName `otopcua-focas-cli`. WriteCommand.ParseValue
handles the full FocasDataType enum (Bit/Byte/Int16/Int32/Float32/
Float64/String — no UInt variants; the FOCAS protocol exposes signed
PMC + Fanuc-Float only). Default DataType is Int16 to match the PMC
register convention.
Full-solution build clean (0 errors). FOCAS CLI wired into
ZB.MOM.WW.OtOpcUa.slnx. No .Tests project for the FOCAS CLI yet —
symmetric with how ProbeCommand has no unit-testable pure logic in the
other 5 CLIs either; WriteCommand.ParseValue parity will land in a
follow-up to keep this PR scoped.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
The previous commit (#248 wiring) inadvertently picked up
src/ZB.MOM.WW.OtOpcUa.Server/config_cache.db — generated by the live smoke
re-run that proved the bootstrapper works. Remove from tracking + ignore
going forward so future runs don't dirty the working tree.
The aahClientManaged SDK is now isolated in ZB.MOM.WW.LmxOpcUa.Historian.Aveva and loaded via HistorianPluginLoader from a Historian/ subfolder only when enabled, removing the SDK from Host's compile-time and deploy-time surface.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Full OPC UA server on .NET Framework 4.8 (x86) exposing AVEVA System
Platform Galaxy tags via MXAccess. Mirrors Galaxy object hierarchy as
OPC UA address space, translating contained-name browse paths to
tag-name runtime references.
Components implemented:
- Configuration: AppConfiguration with 4 sections, validator
- Domain: ConnectionState, Quality, Vtq, MxDataTypeMapper, error codes
- MxAccess: StaComThread, MxAccessClient (partial classes), MxProxyAdapter
using strongly-typed ArchestrA.MxAccess COM interop
- Galaxy Repository: SQL queries (hierarchy, attributes, change detection),
ChangeDetectionService with auto-rebuild on deploy
- OPC UA Server: LmxNodeManager (CustomNodeManager2), LmxOpcUaServer,
OpcUaServerHost with programmatic config, SecurityPolicy None
- Status Dashboard: HTTP server with HTML/JSON/health endpoints
- Integration: Full 14-step startup, graceful shutdown, component wiring
175 tests (174 unit + 1 integration), all passing.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>