Commit Graph

6 Commits

Author SHA1 Message Date
Joseph Doherty de666b24c3 test: fix Galaxy-tag Phase7 test fixtures + S7 CLI enum; add MaterialiseGalaxyTags coverage
v2-ci / build (push) Failing after 38s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
Completes the test side of the in-progress Galaxy-tag workstream:
- Phase7ApplierTests / Phase7ApplierHierarchyTests: supply the now-required
  Galaxy-tag args to Phase7Plan / Phase7CompositionResult.
- Add genuine coverage for Phase7Applier.MaterialiseGalaxyTags (folder-per-distinct-path,
  variable-per-tag node-id derivation, folder dedupe) + added-Galaxy-tags-trigger-rebuild.
- S7.Cli.Tests: use the project's S7CpuType (CLI option type) instead of S7.Net.CpuType.
Whole solution now builds 0/0; OpcUaServer.Tests 52, S7.Cli.Tests 36 green.
2026-05-29 12:18:01 -04:00
Joseph Doherty 64e3fbe035 docs: backfill XML documentation across 756 files
v2-ci / build (push) Failing after 1m43s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public
members surfaced by commentchecker — resolves 5,847 of 5,869 issues
(99.6%) across three /fixdocs passes.
2026-05-28 08:10:17 -04:00
Joseph Doherty 2b811477d1 chore(build): introduce central package management for v2
Adds Directory.Packages.props (ManagePackageVersionsCentrally) and
Directory.Build.props (net10.0/nullable/implicit usings/LangVersion latest).
Strips Version attributes from every csproj PackageReference and consolidates
versions into the central file.

Side fixes (necessary to keep the build green on .NET SDK 10.0.105 on macOS):

- Microsoft.CodeAnalysis.CSharp{,.Workspaces}: 5.3.0 -> 5.0.0. The 5.3.0
  analyzer DLL references compiler 5.3.0.0 and the local SDK ships compiler
  5.0.0.0, producing CS9057 on every project that loaded the Analyzers
  output. Master itself was broken on this machine pre-change.
- Server + Server.Tests pin OPCFoundation.NetStandard.Opc.Ua.{Configuration,
  Client} to 1.5.374.126 via VersionOverride, matching Opc.Ua.Server's
  pin. Mixing 1.5.378.106 Opc.Ua.Core transitively with 1.5.374.126
  Opc.Ua.Server breaks CustomNodeManager2 override signatures
  (CS0115 on LoadPredefinedNodes/Browse/HistoryRead*) and CS7069 in
  the tests. The pin disappears when the legacy Server project is
  deleted in Task 56.
- Client.UI + Client.UI.Tests: NuGetAuditSuppress for
  GHSA-xrw6-gwf8-vvr9 (Tmds.DBus.Protocol 0.20.0 reaches both projects
  transitively from Avalonia.Desktop on Linux/macOS only).

Deviation from the plan: TreatWarningsAsErrors=true is NOT set in
Directory.Build.props because the pre-v2 Admin/Server test projects carry
~240 xUnit1051 analyzer warnings that would fail the build. New v2 projects
opt in via their own csproj; the global flag can return once the legacy
projects are deleted in Task 56.
2026-05-26 03:40:24 -04:00
Joseph Doherty 67ef6c4ebc fix(driver-s7-cli): resolve Low code-review findings (Driver.S7.Cli-004,005,006,007)
- Driver.S7.Cli-004: 'await using var driver' is the sole driver
  disposal path; dropped the redundant explicit await ShutdownAsync from
  each command's finally.
- Driver.S7.Cli-005: deleted the stale empty
  tests/ZB.MOM.WW.OtOpcUa.Driver.S7.Cli.Tests/ directory (the real test
  project lives under tests/Drivers/Cli/).
- Driver.S7.Cli-006: S7CommandBaseBuildOptionsTests cover the probe
  toggle, timeout mapping, host/port/CPU/rack/slot wiring, and tag list
  passthrough.
- Driver.S7.Cli-007: re-added the SubscribeCommand handler comment
  explaining the CliFx IConsole.Output usage and that the poll-thread
  raises events.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-23 08:34:48 -04:00
Joseph Doherty 01a6b6d859 fix(driver-s7-cli): resolve Medium code-review finding (Driver.S7.Cli-001)
Wrap all numeric/DateTime BCL parses in ParseValue with try/catch(FormatException)
and try/catch(OverflowException) that re-throw as CommandException, matching the
existing Bool path. Update ParseValue_non_numeric_for_numeric_types_throws to assert
CommandException (not FormatException), and add an overflow-edge test (Byte value 256).

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-22 10:17:25 -04:00
Joseph Doherty a25593a9c6 chore: organize solution into module folders (Core/Server/Drivers/Client/Tooling)
Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.

- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
  the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
  mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
  integration, install).

Build green (0 errors); unit tests pass. Docs left for a separate pass.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-17 01:55:28 -04:00