The init-time tag guards THREW: one mis-authored tag (DB1.DBZ0, DB1.DBW0 typed
Float64, T5 typed Int32, a writable Bool array) faulted the whole driver and the
actor retried the same init every 10 s forever, darkening every tag on the PLC.
Neither the editor nor the deploy gate checked any of it.
- S7AddressParser moves to S7.Contracts (same namespace) and a new
S7TagShapeRules there is the single authority on servable shapes.
- S7TagDefinitionFactory.FromTagConfig applies it, so the AdminUI editor, the
deploy gate (Inspect, with the specific reason) and the driver init refuse
the same tags. Init now skips a refused tag (ISkippedTagReporter) instead of
throwing; the throwing RejectUnsupportedTagConfigs is gone.
- New rules on top of the old guards: a narrow type at the wrong access width
(every read failed) and a Bool array not starting at bit 0 (U4: DB1.DBX0.3
silently read bit 0 of bytes 0..n).
- AdminUI test fixtures that used addresses the driver could never serve
(DB1.DBS0, a browse "SomeAddress", Int32/Float32 on DBW) now use real ones.
Refs #742
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
ModelBackedCsvDriverTagMap.ApplyTypedColumns round-tripped the row's free-form
TagConfigJson cell through a driver model's FromJson/ToJson to fold the typed
columns in. That load is deliberately lenient — it has to be, so a poisoned blob
can be opened and repaired — so a typo'd value under a key the model owns
("dataType":"Intt16") came back out as the model's DEFAULT, before the #551
import gate or any later gate could judge it. The row imported clean and the tag
the operator described was gone. Only keys the model did not own survived to be
judged, which is why RawTagConfigGateTests looked like it covered this.
MTConnect carried the same defect from the export end. It is the one driver whose
blob accepts several spellings per field, and the runtime PREFERS driverDataType
over the dataType key the MtDataType column writes. The export residual carried
that alias (the map owned only the canonical key), so a re-imported row let it
out-rank the very column the operator had just edited — accepted, then silently
ignored at the driver — while the exported cell printed the spelling the driver
was ignoring, or nothing at all.
The fix preserves evidence; it does not move the verdict:
- ApplyTypedColumns writes the base cell's own tokens back over the model's
serialisation for every key no non-blank typed column overrode. The model still
stamps defaults for keys the row declares nowhere, so fragment cells compose
exactly as before.
- CsvTypedColumn gains ReadKeys / OwnedJsonKeys: the full ordered set of spellings
the RUNTIME reads for that column, mirroring TryFromTagConfig's FirstNonBlank
pairs. A firing column clears the out-ranking aliases; the export residual drops
them; the export cell shows the EFFECTIVE value.
- The review grid's override provenance reads the whole owned set, so an
overridden driverDataType is announced as an overridden dataType would be.
Nothing here decides which values are legal. The verdict stays with
TagConfigValidator on the assembled blob and with IRawTreeService.ImportTagsAsync
behind it — the deliberate reason NOT to follow the issue's own "run the validator
over the pre-merge cell" direction, which would have imposed completeness on a
cell that is legitimately a fragment and false-rejected every typed-column row.
Semantics chosen for the override contradiction: a cell token that a non-blank
column overrides is ACCEPTED with the column winning, and reported by name in
TypedOverrodeFallback. Typed-column-wins is the map's documented contract, the
override is announced rather than silent, and erroring would remove the only way
to repair a poisoned tag through the CSV surface. Every token that reaches the
stored blob is judged; a token the operator overrode is discarded openly.
Falsification: neutering the restore loop + alias handling turns exactly 7 of the
15 new tests red, while RawTagConfigGateTests (#551), RawTagCsvRoundTripTests and
CsvColumnMapReflectionTests all stay green — layering, not replacement.
AdminUI 1248, MTConnect 534, Modbus 373, S7 285, TwinCAT 205 — all green.