Joseph Doherty a1f20e78f9 fix(s7): a CPU refusal is per-tag Bad and counts as answered (R07:H4)
A deterministic PLC refusal (object does not exist, address out of range,
type inconsistent...) degraded driver health, and an all-refused driver (a
wrong DB number) sat Degraded with LastSuccessfulRead frozen, so the 90 s
comms-loss watchdog reconnected it forever against a reachable PLC.

- IsRefusal / IsAccessDenied classify over the whole exception chain. Live
  probe on the snap7 fixture: S7.Net's READ paths raise the item error as a
  BARE Exception ("Received error from PLC: ..."), its write paths as
  PlcException(WriteData). The old PlcException-only match missed the read
  shape entirely, so a real read access-denied was BadCommunicationError +
  Degraded instead of the Faulted PUT/GET alert; the Test Connect probe had
  the same blind spot.
- A refusal (read or write) is BadDeviceFailure with a once-per-tag Warning,
  no health write and no reopen; it counts as answered, so it advances
  LastSuccessfulRead and restores Healthy after a comms fault. An undecodable
  buffer (S7ValueRangeException) also counts as answered.
- A write batch the CPU answered without a failure advances
  LastSuccessfulRead and retires a Degraded the write side itself published.
- Tests that used ReadData as their generic "device fault" now use SendData
  so their Degraded leg is still exercised.

Refs #742
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:20:51 -04:00
Joseph Doherty b36f5644d3 test(s7): wait out the clock tick before asserting LastSuccessfulRead advanced (#589)
The driver stamps DateTime.UtcNow at init and again per read pass; under CPU
contention both land in the same tick, so the strict greater-than assertions
flaked (reproduced 1/40 under load, sibling test A_cancelled_pass_still_flushes...
failed identically with equal timestamps). Test-only race; no production defect.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 00:22:11 -04:00
Joseph Doherty 1765e30063 fix(s7): worst-severity error message + OCE flushes recorded pass evidence (review round) 2026-08-18 07:10:51 -04:00
Joseph Doherty b35e423c1d fix(s7): a read pass that observes nothing reports nothing — empty pass no longer clears Faulted 2026-08-18 07:00:33 -04:00
Joseph Doherty 4c16118105 fix(s7): read-pass health is worst-state-wins — a mixed pass can no longer report Healthy 2026-08-17 07:14:32 -04:00
Joseph Doherty 120e885b31 test(s7): assert the stale handle is disposed, not just replaced, in the cancellation-reopen pins 2026-08-17 05:39:47 -04:00
Joseph Doherty 4f86073333 test(s7): pin the span/multi-var cancellation reopen contract, one-bad-decode-in-chunk, and multi-var shape mismatch 2026-08-17 05:33:45 -04:00
Joseph Doherty 20022083df perf(s7): span leftovers batch through multi-var read PDUs with per-chunk fallback 2026-08-17 04:05:42 -04:00
Joseph Doherty 6ee553cf8f feat(s7): expose ReadMultipleVarsAsync through the IS7Plc seam 2026-08-17 03:48:15 -04:00
Joseph Doherty 39f67a0fce perf(s7): span-grouped reads — one PDU per contiguous block instead of one per tag 2026-08-16 04:15:37 -04:00